Cole Parmer Ultrasonic Hybrid Doppler/transit Time Flowmeter Model 32615-13 New

US $3,000.00

  • King George, Virginia, United States
  • Jan 29th
This Listing Is For A NEW Cole Parmer Ultrasonic Hybrid Doppler/transit Time Flowmeter NEW http://octopart.com/ew-32615-13-cole-parmer-40803917 Noninvasive technology works with both clean or dirty fluids RS-232, RS-485, Ethernet, and USB connections to real-time user PC software No moving parts to wear or requiring maintenance NEMA 4X (IP66) enclosure is weather-resistant for outdoor use, and includes carrying case. These ultrasonic flowmeters can measure fluid flow using either the Doppler or transit time methods, making the meter suitable for use with nearly any fluid that can conduct sound waves. The meters use the latest advancements in DSP (digital signal processing), cross-correlation signal analysis, and a proprietary goodness-of-measurement algorithm to ensure accurate and reliable measurements. Easily adjust factory settings in the field to accommodate any chages in applications, such as pipe size, pipe material, or type of fluid. The clamp-on transducers are rated NEMA 4X (IP66) and include 10 ft. of cable. Each flowmeter comes with the cooresponding size transducer for PVC pipe. Since 1955 Cole-Parmer has been a leading source of laboratory and industrial fluid handling products, instrumentation, equipment and supplies. The company also has expertise in the fields of temperature measurement and control, electrochemistry and fluid handling. Cole-Parmer is renowned for its exceptional customer and technical support. Its highly trained technical application specialists assist with selecting products tailored to your specific application needs and can also help troubleshoot existing systems. Ultrasonic hybrid flowmeters Cole-Parmer’s new ultrasonic hybrid flowmeters can measure fluid flow using either a doppler or transit time method, making them suitable for use with most fluids that conduct sound waves. Cole-Parmer ultrasonic hybrid flowmeters use the latest advancements in digital signal processing (DSP), cross-correlation signal analysis and a proprietary goodness of measurement algorithm to ensure accurate and reliable measurements. These ultrasonic hybrid flowmeters have a 500,000 event data logging capability and can write to a removable SD 32MB memory card. Each flowmeter has a non-invasive transducer that works with both clean and dirty fluids without causing leaks or declines in pressure. The transducer comes with two sets of acoustic coupling gaskets. Common Applications for Ultrasonic Flow Meters Gas-stack flow measurement in power plant scrubbers Cryogenic liquids (time transit ultrasonic flow meters only) Influent and effluent water flow (doppler flow meters only) Waste water (doppler flow meters only) Light to medium crude oils in the petroleum refining industry (time transit meters only) Makeup water Pure and ultra-pure fluids in semiconductor, pharmaceutical, and the food & beverage industries (time transit ultrasonic flow meters only) Digester feed control (doppler flow meters only) Acids and liquefied gases in the chemical industry Cooling water Water distribution systems used in agriculture and irrigation Clarifier monitoring Cole-Parmer's range of ultrasonic flow meters and doppler flowmeters offers process contamination free measurement of liquids and gas flow. A typical ultrasonic flow meter will consist of a transducer that is mounted on to the exterior of the pipe and an indicator or totalizer to display the output. This can easily be installed without disturbing existing pipe work. Most ultrasonic flow meters will work with pipe sizes between 1/2" and 200" diameter. There are two main types of ultrasonic flow meters; doppler flow meters and time transit ultrasonic flow meters. A doppler flow meter requires particulates or bubbles in the media. The minimum diameter size of the particulate is typically 30 microns and requires a minimum concentration levels of 25 ppm. Since some meters may require slightly larger concentrations of particulate, it is a good idea to check the specifications table. Doppler flow meters are mainly used for liquid applications (roughly 88%) while the rest are used for gas (11%) and steam (1%) applications. A time transit ultrasonic flow meter requires a clean liquid without particulates or bubbles and can be used for both liquid and gas applications. It has better accuracy than that of a doppler flow meter and will typically offer accuracies of 2% full scale. Why Use an Ultrasonic Flow Meter Doppler flow meters are suitable for slurries Suitable for aggressive chemicals as no contact with the media Allows for easy installation without disturbing existing pipe work Process contamination free measurement of flow No leak potential ANY QUESTIONS CALL 540-413-6934 Thanks Art Location: WH2 Rack 13 Shelf 3 Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.

Directions

Similar products from Gas & Water Flow Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies