Contec Ms200 Nibp Simulator Non-invasive Blood Pressure Simulation Simulator

US $280

  • Elk grove village,Illinois 60007-4825, United States
  • Aug 4th
                                                                                                        CONTEC MS200 NIBP Simulator Non-Invasive Blood Pressure simulation Simulator                  Introduction It is a multi - purpose test device for testing NIBP Monitor adopted Oscillometry. Concise and elegant in appearance, easy and convenient to operate, and it can generate the pressure up to 400mmHg (53.3 kPa) by the built-in air pump. With the functions of dynamic BP simulation under several conditions, static pressure calibration, automatic leak test and over-pressure relief test, which can quickly and accurately analyze each performance of NIBP Monitor. Functions 1)Pressure leak test 2)Over-pressure relief test 3)BP simulation under standard condition 4)BP simulation under patient condition 5)BP simulation under arrhythmia condition 6)BP simulation under respiratory interference condition 7)BP simulation of neonate 8)Wrist BP simulation 9)User-defined BP simulation 10)System setting function. 11)The parameters set can be stored. 12)ON/OFF function 13)Dynamic BP simulation Performance BP simulation range: Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg) Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg) Pulse volume: 0.1 cc ~ 2.4 cc   HR range: 30 bpm ~ 250 bpm; pulse volume > 2.00 cc, maximum HR: 200 bpm HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance)   Under patient condition: Weak pulse, tachycardia, obese, geriatric:   ±preset value 1%+1bpm Moderate exercise:                     ±preset value 1.5%+1bpm Strenuous exercise:                    ±preset value 3%+1bpm Pressure measurement: Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Accuracy: 0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg 40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading Pressure leak test Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds. Over-pressure relief test Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure. Pressure source: Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc Airtightness Total airtightness: < 0.3 kPa/min (2.25 mmHg/min) under “OFF” state Airtightness of built-in cuff: 0.27 kPa/min (2 mmHg/min) BP simulation preset value configuration table BP simulation    BP preset value    BP    HR    Pulse volume Standard BP simulation    #1    120/8093    80bpm    0.68cc     #2    150/100116        0.65cc     #3    200/150166        0.60cc     #4    255/195215        0.55cc     #5    60/30(40)        0.75cc     #6    80/5060        0.71cc     #7    100/6576        0.69cc BP simulation under patient condition     Healthy heart    120/80(93)    75bpm    0.68cc     Weak Pulse    110/80(90)    95bpm    0.50cc     Mild Exercise    140/90(106)    120bpm    1.00cc     Strenuous Exer    140/90(106)    162bpm    1.40cc     Obese    120/80(93)    90bpm    0.50cc     Geriatric    150/110(123)    95bpm    0.40cc     Tachycardia    120/105(110)    130bpm    0.40cc     Bradycardia    120/60(80)    45bpm    1.10cc BP simulation under arrhythmia condition     Premature Atrial Contraction1    138/53(81)    80bpm    0.70cc     Premature Atrial Contraction2    144/64(90)    83bpm          Premature Ventricular Contraction    118/61(80)    83bpm         Atrial Fibrillation and PVC    139/72(94)    91bpm     BP simulation under respiratory interference condition     spontaneous breathing1    138/65(89)    104bpm    0.60cc     spontaneous breathing2    149/65(93)    105bpm         spontaneous breathing3    112/47(68)    86bpm         controlled breathing    132/44(73)    98bpm     BP simulation of neonate     #1    35/15(22)    120bpm    0.11cc     #2    60/30(40)        0.10cc     #3    80/50(60)             #4    100/70(80)         BP simulation of wrist cuff     #1    120/80(93)    80bpm    0.50cc     #2    160/100(120)             #3    80/55(63)         User-defined BP simulation[1]    -    -    -    - Note[1]Support 9 user-defined BP simulation modes. The following parameters can be defined by users:2.3.1.The value of diastolic pressure should be lower than systolic pressure, pulse volume and HR can not be set to the highest values (e.g., pulse volume 2.00cc, HR: 250 bpm; pulse volume > 2.00cc, HR: 200bpm). Accessories One User Manual Two fuses One power cord Physical characteristic Display: 4.3" 65 K color LCD display Power supply: AC100 ~ 240 V   50/60 Hz, <60 VA Environment temperature: + 5 ~ + 40 Relative humidty: < 90 %, non-condensing Altitude: 3000 m Atmospheric pressure: 80 kPa ~ 106 kPa Dimension: 270 (L) 265 (W) 132 (H) mm Weight: about 4 kg Certification CE                                                                                
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model MS200
MPN Does Not Apply
Country/Region of Manufacture China
Brand CONTEC
Mounting Portable
Intended Use/Discipline Biological Laboratory, Emergency Medicine
Features Touchscreen
UPC Does not apply

Directions

Similar products from Blood Pressure Measurers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies