Contec Neonatal Infant Kids Born Pulse Oximeter Spo2 Monitor Sleep Recorder Fda

US $99.00

  • Beijing, China
  • Aug 14th
                                                                                                        CONTEC Neonatal Infant  Kids Born Pulse Oximeter Spo2 Monitor Sleep Recorder FDA                 Instructions The CMS60C Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology, which can be used to measure human oxygen saturation and pulse rate through finger. The device is suitable for being used in hospital, oxygen bar, community healthcare and physical care in sports, etc. (It can be used before or after exercise, but not recommended to use during exercising). Features Small in volume, light in weight and convenient in carrying Easy to operate, low power consumption Operation menu for function settings SpO2 value display Pulse rate value display, bar graph display Pulse waveform display Display direction can be changed Screen brightness can be changed Pulse rate sound indication With measured data overruns limits and low-voltage alarm function, the upper/lower alarm limit can be adjusted Battery capacity indication Low-voltage indication: Low-voltage indication appears before working abnormal caused by low voltage. Data storage function, stored data can be uploaded to computer Data transmission in real-time External SpO2 probe Performance Display mode: 1.77" TFT color screen Screen resolution: 128*160 SpO2 measuring range: 0%~100% (resolution is 1%) Accuracy: 70%~100%: ±2%, Below 70% unspecified. PR measuring range: 30bpm~250bpm (resolution is 1bpm) Accuracy: ±2bpm or ±2% (whichever is greater) Measurement performance in weak filling condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2bpm or ±2% (whichever is greater). Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%. Voltage: DC 3.6V~4.2V Power supply: 3.7V rechargeable lithium battery 1 Battery working hour: 26 hours in theoretical Battery service life: no less than 500 times of charge and discharge Safety type: Internally powered equipment, Type BF applied part Accessories Standard: User Manual 1pc Lithium battery 1pc Power adapter 1pc Data line 1pc CD (PC software) 1pc Infant Probe 1pc Optional: Other SpO2 probes Physical characteristic Dimension: 87(L) 45(W) 22(H) mm Weight: about 75g (with one lithium battery) Buy Safe Product!! The following FDA Disclaimer is required for all eBay listing in  Healthcare category and is included for REFERENCE:  The sale of this item may be subject to regulation by the U.S.  Food and Drug Administration and state and local  regulatory agencies. If the item is subject to FDA regulation,We will verify your  status as an authorized purchaser of this item before shipping  of the item.  The model is registered on the Australian Register of  Therapeutic Goods (ARTG) with the code 197923, and certified  by FDA 510K Approved of America and CE,TUV of Europe About Us Contec Medical Systems Co., Ltd. (hereinafter referred to as CONTEC) focusing on research, manufacture and distribution of medical instruments, was founded in 1996 as a high-tech company. CONTEC locates in Economic & Technical Development Zone in Qinhuangdao covered an area of 125 acres and building area of over 100000 square meter, which is one of the largest bases for R & D and production of medical devices in China. Contec hopes to cooperate with international companies to supply more innovative design and advanced  technology  products  We sincerely welcome you to become one of our global partners. We are looking forward to establishing a successful business relationship with you. Contact Us Skype:  contecbelinda Tel:+86-335-8015561(CN) Cell phone: +86 13731396681 Emailcontec--belindaahotmail.com                                      Powered by SoldEazy Only English user guide, if you need any other language, please contact us!
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model CMS60C with infant probe
MPN 69450401
Country/Region of Manufacture China
Brand CON-TEC
UPC Does not apply

Directions

Similar products from Pulse Oxymeters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies