Cr-2 Generator Interlock Kit For Challenger, Westinghouse, Thomas & Betts Panels

US $800

  • Alpine, New York, United States
  • Jun 5th
CR-2 Generator Interlock Kit this kit fits brands: Challenger, Westinghouse, Thomas & Betts type of circuit breaker panel: 2 handle horizontal throw main breaker offset 7/8" left of center and 1 1/4" above two breaker columns panel spaces used: 2 at the top of the right side breaker column National Electrical Code requires a system in place that prevents an emergency generator from feeding back into the utility line. This interlock will only allow the generator breaker to be switched on if the main breaker is off. Or the main breaker to be turned on if the generator breaker is off. You will also need: A generator with a 240 volt outlet A double breaker located at the top of the right side breaker column of your electrical panel box An inlet box and wiring connected to that double breaker Using this interlock will allow you to power your existing house wiring with your generator (within its wattage limits), including 220 volt circuits such as a well pump.  This interlock is not listed. It does meet the requirements of Article 702 of the National Electrical Code ANSI/NFPA 70.

Directions

Similar products from Electrical breadboards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.