Dental Wireless Led Curing Light Lamp 1 Second Cure Lamp Wide Specturm 2200mw/cm

US $199.00

  • Beijing, China
  • Sep 3rd
Welcome to our ebay store! Dental Cordless LED Curing Light Lamp 1 Second Deep Cure Wide Specturm 2200MW  Description Model : CV-215-I A new advanced cordless LED curing light. It can provide the maximum light intensity safely and consistently. Features: - With the high intensity of 2,200 mW/cm - Wave length Range : 390nm ~ 470nm - Full coverage for all optical meterials - Aviation-grade metal body for better heat dissipation - Wireless fast charging mode with indicator - Provide light intensity test for secure use - Three modes for option . P1(1~3s) P2(5~20s)P3(10-20s) - Automatic power off, low battery alert Principle and usage: CV-215-I adopts the principle of ray radiation light-sensitive resin by shooting at it in a short time.  Technical specifications: Dimensions: 25mm x 224 mm Net weight: 193 g Power source: 1.Power supply: rechargeable Lithium battery 2.Battery mode: ICR 18490 3.Battery voltage and capacity: 3. 7V/2000mA   Battery has protection against Over-voltage, over-current and short circuit   Power Input: AC 100V-240V, 50HZ/60Hz   Input Power: IOVA   Power Output: DC5V/IA Light source:  1.10w high power blue light LED 2.Checking method: the LED light is fine when the light is on during correctly 3.The wave length of this product can match with the clinical dental resin solidification, such as 3M, Dentsply etc 4.Wave length: 380nm-470nm Light intensity: 1600 mW/cm2-2200mW/cm Working condition: 1 Environment temperature: +10C to +40C 2 Relative humidity: 30%-75% 3 Atmosphere pressure: 70kPa to106kPa Equipment safety 1.Operating mode: intermittent operation 2.Protection type against electrical shock: class II 3.Protection degree against electrical shock: type B 4.Protection against harmful ingress of water or particular matter: rdinary equipment(IPXO) 5.Safety in the presence of flammable anesthetic mixture with air, oxygen or nitrous oxide: not suitable under this condition Install and uninstall way: 1.The top of the unit can be turned 360 degrees to both left and right while it is forbidden to remove 2.When the battery needs to be charged, connect the plug of the adapter into the AC100V--240V power supply. Then connect the output plug of the adapter to the DC 5 0V input plug of the pedestal, then put the main unit into the pedestal Operation: Press the mode button. Following two modes are available Long press P/T button can exchange PI and P2 mode. when it shows P1 01, tap button to P1 03, Long press to model P2 (5S,10S,15S,20S) 2 During the operation, put the disposable sleeve on the top of the main unit, aim the top at the correct position, press the ON/OFF button and the main unit will produce"Bi"sound, the curing light radiates blue light and starts working according to the set modes. Meanwhile, it starts counting down and will produce tone at every 5 seconds, it stops working when counting down to 0 3 During operation, the blue light can be stopped by press the power button at any time 4 After a working cycle, operator can press the ON/OFF switch to start another working cycle. Stop operating if the equipment began to heat obviously, do not restart until the equipment cool down. Sugges continues working cycle less than 10 times 5 Low power detective circuit is fixed inside of the main unit, when low power is detected, the display screen of main unit will wink, please charge in time 6 When the battery needs to be charged, connect the plug of the adapter into the AC100V-240V power supply. Then connect the output plug of the adapter to the DC 5.0V input plug of the pedestal, and then the logo turn to blue. Put the main unit to the charging point of the pedestal the display screen turn to scrolling display, and the curing lights starts charging 7 After operating, take off the disposable sleeve and throw away, forbidden to reuse 8 This equipment will turn off automatically if don t any action within 2 minutes, turn it on by press any button 9 The depth of solidification of composite is no less than 2mm per I second Precaution: 1 Please recharge the battery at least 4 hours before first time usage 2 In order to prevent cross-infection, it is forbidden to reuse the disposable sleeve 3 The top of the main unit can be turned 360 degrees to both left and right while it is forbidden to remove 4 During operation, the blue light should be aimed straightly at the omposite resin to ensure the effect of solidification 5 Avoid aiming the blue light at eyes directly 6 Please use the power adapter and lithium battery which is designed and supplied by our company. It may cause potential dangers to operator and patient by using the power adapter and lithium battery which is designed and supplied by other manufacturers 7 It is forbidden to use metal or other conductors to touch the main Init and the charging point of pedestal because it may burn the internal circuit or make the lithium battery short circuit 8 Please recharge the battery in cool and ventilated room 9 It is forbidden to self-taking apart the battery, in order not to result in short-circuit or leakage 10 It is forbidden to extrude, shake or rock the battery. The Li-ion battery is forbidden to be in short-circuit situation and it is forbidden to put the battery with metal or other conductors 11 To invoid electromagnetic interference, the device should be installed at the medical site which meet the requirement of EMC. 1.WARNING: If the curing light works for 40s continously, the temperature of the top of optical fiber may reach 56C 2.WARNING: Do not modify this equipment without authorization of the manufacturer. 3.WARNING: The adapter should be connected to the socket which is easy for operator to touch 4.WARNING: over-heat scorching: interval time should be no less than Contraindication: The heart disease patients, pregnant women and children should be cautious to use this equipment. Daily maintenance: 1 This equipment does not include the self-maintainable spare parts The maintenance of this equipment should be taken by the appointed professional or special repair shop 2 Users can change the disposable sleeve and lithium battery. Please use accessory which is designed and supplied by our company, contract with the local dealer or our company if you want to buy. It may cause potential dangers to curing light or other damages which is designed and supplied by other manufacturers 3 The accessory of the product should be cleaned by clean water or neutral sterilized liquid. Do not soak. Do not use highly volatile and diffluent solvent to clean this equipment, which can cause the signs on the control pa 4 Please clean the resin remained on the top of the main unit after using to avoid infecting the life-span or solidified effect 5 The device cannot be maintanenced during operation. And it is suggested to maintain it once a month. But sleeve is for one-time usage and no need for maintanance 510(K) Number: K192233 Regulation Number: 21 CFR 872.6070 Product Code: EBZ Shipping International Shipping to worldwide. Handling within 24 business hours. Tracking info of your parcel is available. Returns could be accepted within 60 days after receipt of the item. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. It usually takes 15-45 business days to arrive by economy international shipping and 7-12 business days by express. The following form is for your reference. Feedback IMPORTANT INFORMATION ON OUR POLICY AND FEEDBACK Please leave me FIVE STAR POSITIVE feedback if you are satisfied with our items.   We try to be fair and accurate with all of our product listings and descriptions. Please read each auction, bid, and sale carefully. We will appreciate it if you please email us before leaving negative feedback. If there is a problem, we can work together to resolve it. We strive to always be extremely fair and always try to work with reasonable customers. Negative feedback doesn't go away and should only be left as a last resort! We strive for positive feedback, harmonious relations and even friendships. We will always make every attempt possible to resolve issues if we made a mistake.(It happens). Please do not assume a mistake is intentional. Let us know if our service could be better!! Payment We accept PayPal payment ONLY, it is easy and safe. Payment should be sent within 7 (SEVEN) days of auction closing. All winning bidders whom won our item, please let me know your contact number after you made the full payment , we need this number to make sure you can receive your item in time, and also for emergency contact consideration.   Returns  Returns could be accepted within 30 days after receipt of the item. Terms of Sale: Refund or replacement request is available only the requests within 1 week after parcel received & returning the item as the same condition as received. Please contact us to request a return authorization. Your name, auction number, and reason for return should be included in the email. All items returned must contain all original packaging materials.Please repack the item carefully. Items returned will be tested and a new replacement will be shipped to the buyer immediately when found defective. In the event that a suitable replacement is not available then a refund will be issued. Shipping, handling and insurance fees are non refundable. If the item is found non-defective, the item will be sent back to the buyer at buyer's expense. Items returned without RMA number will be refused and returned to the sender. Buyer is responsible for All Return Postage and Shipping Charges. Buyer is responsible for additional shipping costs for items that are returned refused and / or undeliverable. We do not accept any returns without an authorization number on the box or label it is being returned. Contact us We will reply all messages within 24 business hours and we are able to give you a quick response during the duty time. If we are off duty, please kindly be patient and give us a little more time, not just leave the neutral or negative feedback without communication. Every problem will be solved ASAP if you contact us! Our working time Monday To Friday: 9:00 am --- 12:00am 1:30pm ---6:00pm (Please Refer to Beijing Time.) Copyright©Dreamland Dental Store,All rights reserved.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Classification Product Code EFB
Input Voltage AC100~240V, 50/60Hz
510(K) Number For Dental Handpiece K181691
Modified Item No
Regulation Number for Curing Light 21 CFR 872.6070
Charging mode Wireless fast charging mode with indicator
510(K) Number For Curing Light K192233
Intended Use/Discipline Dental Laboratory, Dentistry
Product Code For Curing Light EBZ
Brand Unbranded
510(K) Number For Scaler K163414
Advantage Full coverage for all optical meterials
Regulation Number For Dental Handpiece 872.4200
Provide light intensity test for secure use
Subsequent Product Code EGS
Model CV-215-I
Product Code For Scaler ELC
Light intensity 2200 mW/cm
Regulation Number for Scaler 872.4850
Full coverage for all optical meterials
FDA K192233
Light Type LED
Custom Bundle No
Featured Refinements Dental LED Curing Light
Three modes for option P1(1~3s) P2(5~20s)P3(10-20s)
Aviation-grade metal body for better heat dissipation
Product Code EBZ
Country/Region of Manufacture China
510(K) Number K192233
Regulation Number 21 CFR 872.6070
MPN Does Not Apply
Wavelength Range 390nm ~ 470nm

Directions

Similar products from Light Curing Units