Efi Es-2000 Spectrophotometer I1 Pro Rev.e Eye1 X-rite Color Profiler Suite 4.6

US $1,150.00

  • Malibu, California, United States
  • Mar 7th
EFI ES-2000 spectrometer/spectrophotometer hardware revision 'E' with Color Profiler Suite 4.6 license. Keep in mind that CPS 4.6 software with license alone is $2,400 and it will work only with the licensed spectrometer (such is this one)! Just the Color Profiler Suite 4.6 license is worth way more than the listing price and you will also get the spectrometer! This unit is new, never been used, lamp burning time is less than 3 seconds, which was used to test it with i1 SW: see the end of the description for a log file from i1 test software and the pictures of the screen shots. This spectrometer does have a few very small scratches on the top, but those are purely cosmetic. ES-2000 is fully backward compatible with any software that works with ES-1000, it just has a better color accuracy and a couple of other options. The serial number is 7013678, it includes a license to use it with Color Profiler Suite 4.x (see the screen shot of EFI activation page): retail price on the software+ES-1000 is $3,400! License for CPS 4.6 was first activated on March 6, 2015, so you will get the 1 year support from EFI. Here are the links to EFI: $1,348 for ES-2000 only https://estore.efi.com/shop/asp/product_info.aspx?pid=45109642 and $3,400 for ES-2000+CPS 4.6 https://estore.efi.com/shop/asp/product_info.aspx?pid=3000005452 You can download the CPS 4.6 for free from EFI: Windows: https://d1umxs9ckzarso.cloudfront.net/Products/CPS/Win_FCPS_4.6.2.19.exe Or Mac: https://d1umxs9ckzarso.cloudfront.net/Products/CPS/Mac_FCPS_4.6.2.19.dmg  and run it in 'demo' mode, once a licensed spectrometer (such as this one) is connected to USB port, the CPS becomes fully functional. This unit is an essential piece of equipment for any print shop and almost mandatory if you are using any Fiery or Colorpass print controllers regardless of the brand of the machines that they are attached to: Konica Minolta, OCE, Canon, Ricoh, HP, Xerox, Toshiba etc. ES-2000 can also be used to calibrate plotters/commercial inkjets/offset printers as long as the print controller/rip and the calibration software is compatible with it. You can use this spectrophotometer with the newer models (with Fiery option) such as Konica Minolta Bizhub C70HC/C6000/C7000/C8000/C1060/C1070/C1085/C1100, C224, C284, C364, C454, C554, C664, C754 etc. All versions of Command Workstation which were using ES-1000 (it is used to calibrate the controllers) support ES-2000. Usually copiers/printers should be calibrated every 1-3 weeks depending on the volume of printing: as the drums and developers get older, the color deviates and you could be getting a cyan, magenta or yellow hues on the prints. Calibrating the Fiery will return the colors to their normal balance (assuming that your machine is working properly) and takes only about 5 minutes: just open the Command Work Station program, connect the spectrometer to USB port, connect to your server, click on 'calibrate' and follow the prompts. Your Fiery will print the C/M/Y/K test page, you will scan the color bars and click 'apply', that's it. ES-2000 also allows you to calibrate the monitors. Included items are: ES-2000, matched calibration cradle, calibration table with a positioning ruler, USB cable, positioning guide, monitor adapter and the original storage case. Feel free to contact with any questions. Below is the test results log from i1 software. ****************************************************************************************************************************************************************************** Start testing General Information   Date and Time: 3/7/2015 12:45:51 PM   Application version: 4.0.0.127, 32-bit   SDK version i1Pro: 4.1.1.1572   SDK version i1iO: 2.1.1.1572   Platform: Microsoft Windows 7 Ultimate Edition Service Pack 1, 64-bit i1iO Connection test   i1Pro not mounted on i1iO Open instrument   Connection: Successful   Open instrument: Successful Instrument information   Instrument inspection: Successful   Serial number i1Pro: 7017922   Type: i1Pro   Revision: E   Firmware version: 634   CPLD version: 999   Dark measurement count: 5   Lamp burning time: 2.2 seconds   Spot measurement count: 5   Scan measurement count: 0   Factory calibration: 7/3/2013   Spectral Module ID: 01-28131a160000a0   Supplier: 'EFI-ES2000'   Warranty start date: 4/30/2014 3:18:28 AM   Recertification date: - Instrument Licenses   Measurement Modes: [Reflectance Spot, Reflectance Scan, Emission, DualReflectance Spot, DualReflectance Scan]   Licensed functionality: [Has UV LED, Has Wavelength LED, Has Zebra Ruler sensor, Max Ruler Length = 300 mm, Has Indicator LED, Spectral values, Tristimulus, Density]   Licensed Modules:   i1Match Module "Scanner": NOT licensed   i1Match Module "Monitor": licensed   i1Match Module "Printer": NOT licensed   i1Match Module "Printer RGB only": NOT licensed   i1Match Module "Printer CMYK only": NOT licensed   i1Match Module "Beamer": NOT licensed   i1Match Module "Printer Easy RGB": NOT licensed   i1Match Module "Printer Easy CMYK": NOT licensed   i1Match Module "Digicam": NOT licensed   i1Match Module "Editor": NOT licensed   i1Profiler Module "Display Profiling": NOT licensed   i1Profiler Module "RGB Printer Profiling": NOT licensed   i1Profiler Module "CMYK Printer Profiling": NOT licensed   i1Profiler Module "Printer QA": NOT licensed   i1Profiler Module "Advanced-Mode": NOT licensed   i1Profiler Module "Projector": NOT licensed Button test   Button: Successful Emission test   Emission calibration: Successful   Prepare the instrument for emission measurement   White measurement: Successful   Gray measurement: Successful   Black measurement: Successful   Red measurement: Successful   Green measurement: Successful   Blue measurement: Successful   Emission: Successful Button test   Button: Successful Noise Tests   Noise measurements: Successful   Noise result: Successful Reflectance test   Reflectance Spot calibration: Successful   Reflectance Spot measurement 1: Successful   Reflectance Spot measurement 2: Successful   Reflectance Spot measurement 3: Successful   Reflectance Spot measurement 4: Successful   Reflectance Spot measurement 5: Successful   Reflectance Spot measurement 6: Successful   Reflectance Spot measurement 7: Successful   Reflectance Spot measurement 8: Successful   Reflectance Spot measurement 9: Successful   Reflectance Spot measurement 10: Successful   Lamp test: Successful   Reflectance drift test: Successful   Reflectance Scan calibration: Successful   Dual Reflectance Spot calibration: Successful   Dual Reflectance Spot test: Successful   Dual Reflectance Scan calibration: Successful Positioning Sensor Test   Scan with positioning sensors: Fail (Insufficient movement) Repeating test... Positioning Sensor Test   Scan with positioning sensors: Successful (Moving distance: 26.1 cm) *** PASS *** ************************** Start testing General Information   Date and Time: 2015-03-07T12:45:51   Application version: 4.0.0.127, 32-bit   SDK version i1Pro: 4.1.1.1572   SDK version i1iO: 2.1.1.1572   Platform: Microsoft Windows 7 Ultimate Edition Service Pack 1 (Build 7601), 64-bit i1iO Connection Test   i1Pro not mounted on i1iO Open instrument   Connection: Successful   Open instrument '\\?\usb#vid_0971&pid_2000#5&30bfda7f&0&1#{989d6515-e122-4442-a357-751457f102a5}': Successful Instrument information   Instrument inspection: Successful   Serial number i1Pro: 7017922   Type: i1Pro   Revision: E   Firmware version: 634   CPLD version: 999   Dark measurement count: 5   Lamp burning time: 2.2 seconds   Spot measurement count: 5   Scan measurement count: 0   Factory calibration: 2013-07-03   Spectral Module ID: 01-28131a160000a0   Supplier: 'EFI-ES2000'   Warranty start date: 2014-04-30T03:18:28   Recertification date: - Instrument Licences   Measurement Modes: [ReflectanceSpot, ReflectanceScan, EmissionSpot, DualReflectanceSpot, DualReflectanceScan]   Licensed functionality: [Has UV LED, Has Wavelength LED, Has Zebra Ruler sensor, Max Ruler Length = 300 mm, Has Indicator LED, Spectral values, Tristimulus, Density]   Licensed Modules:   i1Match Module "Scanner": NOT licensed   i1Match Module "Monitor": licensed   i1Match Module "Printer": NOT licensed   i1Match Module "Printer RGB only": NOT licensed   i1Match Module "Printer CMYK only": NOT licensed   i1Match Module "Beamer": NOT licensed   i1Match Module "Printer Easy RGB": NOT licensed   i1Match Module "Printer Easy CMYK": NOT licensed   i1Match Module "Digicam": NOT licensed   i1Match Module "Editor": NOT licensed   i1Profiler Module "Display Profiling": NOT licensed   i1Profiler Module "RGB Printer Profiling": NOT licensed   i1Profiler Module "CMYK Printer Profiling": NOT licensed   i1Profiler Module "Printer QA": NOT licensed   i1Profiler Module "Advanced-Mode": NOT licensed   i1Profiler Module "Projector": NOT licensed Button Test   Button: Successful Emission test   Emission calibration: Successful   Prepare the instrument for emission measurement   White measurement: Successful (X=203.728 Y=222.107 Z=202.964)   Gray measurement: Successful (X=77.805 Y=84.353 Z=82.920)   Black measurement: Successful (X=0.216 Y=0.222 Z=0.373)   Red measurement: Successful (X=97.183 Y=50.763 Z=3.240)   Green measurement: Successful (X=75.295 Y=155.102 Z=27.013)   Blue measurement: Successful (X=31.396 Y=16.309 Z=172.753)   Emission: Successful Button Test   Button: Successful Noise Tests   Noise measurements: Successful   Noise result: Successful (electronic noise: 2.987) Reflectance test   Reflectance Spot calibration: Successful (WLS=0.25)   Reflectance Spot measurement 1: Successful (96.044, -0.392, 2.158)   Reflectance Spot measurement 2: Successful (96.045, -0.385, 2.140)   Reflectance Spot measurement 3: Successful (96.049, -0.387, 2.124)   Reflectance Spot measurement 4: Successful (96.046, -0.391, 2.127)   Reflectance Spot measurement 5: Successful (96.038, -0.385, 2.121)   Reflectance Spot measurement 6: Successful (96.035, -0.385, 2.132)   Reflectance Spot measurement 7: Successful (96.032, -0.390, 2.137)   Reflectance Spot measurement 8: Successful (96.028, -0.380, 2.132)   Reflectance Spot measurement 9: Successful (96.027, -0.381, 2.129)   Reflectance Spot measurement 10: Successful (96.024, -0.386, 2.130)   Lamp test: Successful (minL=96.024 meanL=96.037 MIT=0.0131400004 CIT=0.0131400004 LOT=4.74018764)   Reflectance drift test: Successful (0.012)   Reflectance Scan calibration: Successful (WLS=0.300000012)   Dual Reflectance Spot calibration: Successful (WLS=0.300000012)   Dual Reflectance Spot test: Successful   Dual Reflectance Scan calibration: Successful (WLS=0.300000012) Positioning Sensor Test   Scan with positioning sensors: Fail (insufficient movement - 'Exception in I1_Private: Device not moved enough on ruler during scan' - 0x4003324 - Event: 'i1Pro button pressed') Repeating test... Positioning Sensor Test   Scan with positioning sensors: Successful (min: 0.000, max: 0.261, total distance: 0.261) *** PASS *** **************************
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Brand EFI
MPN EO2-EFI-ULZV
Model ES-2000

Directions

Similar products from Spectrophotometers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies