Efi Es-2000 Spectrophotometer I1 Uvcut Rev.e Eye1 X-rite Color Profiler Suite 4

US $515

  • Malibu, California, United States
  • Jun 21st
Demo EFI ES-2000 x-rite i1 Pro revision E UV-cut spectrometer/spectrophotometer/densitometer with license for Color Profiler Suite 4.x Serial number is 7009721 Please note that this spectrometer is licensed and works with Color Profiler Suite software 4.0 through 4.5: if you want to use it with the later versions such as 4.6 or 4.8, you would have to renew/purchase the SMSA (software maintenance and support agreement) contract from EFI. This ES-2000 is a demo unit, lamp burning time is 1524.4 seconds (25 minutes) which was used for a few demos to a potential customers and to test it with i1 and CPS software: see the pictures and the log file. It is licensed for use with CPS versions 4.x, 3.x and 2.x: see the screenshots of the EFI activation page; retail price for the ES-2000 plus CPS 4 software is $3,300 (as you probably know and it is even more expensive in Europe), here is the link to EFI website: http://www.efi.com/products/fiery-servers-and-software/fiery-workflow-suite/fiery-color-profiler-suite/overview/ The license alone for CPS 4.5 is worth $2,300, but you will also get the ES-2000 spectrometer which retails for $1,300. Spectrophotometer is almost mandatory if you are using any Fiery driven copiers/printers regardless of the manufacturer (Konica Minolta, Canon, Toshiba, Xerox, HP, Ricoh, Sharp etc.) since the color deviates from use and you could be getting cyan/magenta/yellow hue on the prints; calibration is very easy, should be done every 1-4 weeks (depending on the printer usage) and takes less than 5 minutes. You would just open Command Work Station software (free download from EFI), connect to your machine, plug the spectrometer to USB port, click 'calibrate', print the c/m/y/k test page, scan the bars and click 'apply'. ES-2000 is 100% backwards compatible with any software or a Fiery print controllers that worked with ES-1000, but it provides better color accuracy and a few other options. You can download the Color Profiler Suite 4.5 from EFI website, just have to put in your info:  http://www.efi.com/support-and-downloads/download-center/?type=apps&oem=efi&sid=FieryColorProfilerSuite&model=287~v4.5.2.12&os= and run it in demo mode, once a licensed spectrometer (such as this one) is connected to USB port, the software becomes fully functional (see the screenshot). Here are also the direct links for download of CPS 3.1 Windows https://d1umxs9ckzarso.cloudfront.net/Products/CPS/Win_FCPS_3.1.2.01.exe Mac  https://d1umxs9ckzarso.cloudfront.net/Products/CPS/Mac_FCPS_3.1.2.01c.dmg Included in this listing are all of the items that come with a new unit: ES-2000 with cradle Monitor adapter Positioning guide USB cable Calibration table with ruler Storage case CD with a copy of CPS 4.5 software ************************************************** Feel free to contact with any questions or if you would like to buy before the end of the auction. Here is the copy of the test log: *************************************************** Start testing General Information   Date and Time: 6/20/2016 1:38:50 PM   Application version: 4.0.0.127, 32-bit   SDK version i1Pro: 4.1.1.1572   SDK version i1iO: 2.1.1.1572   Platform: Microsoft Windows 8 Professional, 64-bit i1iO Connection test   i1Pro not mounted on i1iO Open instrument   Connection: Successful   Open instrument: Successful Instrument information   Instrument inspection: Successful   Serial number i1Pro: 7009721   Type: i1Pro   Revision: E   Firmware version: 634   CPLD version: 999   Dark measurement count: 458   Lamp burning time: 1524.4 seconds   Spot measurement count: 47   Scan measurement count: 389   Factory calibration: 3/15/2013   Spectral Module ID: 01-957adf15000053   Supplier: 'EFI-ES2000'   Warranty start date: 1/2/2014 4:06:27 AM   Recertification date: - Instrument Licenses   Measurement Modes: [Reflectance Spot, Reflectance Scan, Emission, DualReflectance Spot, DualReflectance Scan]   Licensed functionality: [Has UV LED, Has Wavelength LED, Has Zebra Ruler sensor, Max Ruler Length = 300 mm, Has Indicator LED, Spectral values, Tristimulus, Density]   Button test   Button: Successful Emission test   Emission calibration: Successful   Prepare the instrument for emission measurement   White measurement: Successful   Gray measurement: Successful   Black measurement: Successful   Red measurement: Successful   Green measurement: Successful   Blue measurement: Successful   Emission: Successful Button test   Button: Successful Noise Tests   Noise measurements: Successful   Noise result: Successful Reflectance test   Reflectance Spot calibration: Successful   Reflectance Spot measurement 1: Successful   Reflectance Spot measurement 2: Successful   Reflectance Spot measurement 3: Successful   Reflectance Spot measurement 4: Successful   Reflectance Spot measurement 5: Successful   Reflectance Spot measurement 6: Successful   Reflectance Spot measurement 7: Successful   Reflectance Spot measurement 8: Successful   Reflectance Spot measurement 9: Successful   Reflectance Spot measurement 10: Successful   Lamp test: Successful   Reflectance drift test: Successful   Reflectance Scan calibration: Successful   Dual Reflectance Spot calibration: Successful   Dual Reflectance Spot test: Successful   Dual Reflectance Scan calibration: Successful Positioning Sensor Test   Scan with positioning sensors: Successful (Moving distance: 25.2 cm) *** PASS *** ************************** Start testing General Information   Date and Time: 2016-06-20T13:38:50   Application version: 4.0.0.127, 32-bit   SDK version i1Pro: 4.1.1.1572   SDK version i1iO: 2.1.1.1572   Platform: Microsoft Windows 8 Professional (Build 9200), 64-bit i1iO Connection Test   i1Pro not mounted on i1iO Open instrument   Connection: Successful   Open instrument '\\?\usb#vid_0971&pid_2000#6&36f05019&0&1#{989d6515-e122-4442-a357-751457f102a5}': Successful Instrument information   Instrument inspection: Successful   Serial number i1Pro: 7009721   Type: i1Pro   Revision: E   Firmware version: 634   CPLD version: 999   Dark measurement count: 458   Lamp burning time: 1524.4 seconds   Spot measurement count: 47   Scan measurement count: 389   Factory calibration: 2013-03-15   Spectral Module ID: 01-957adf15000053   Supplier: 'EFI-ES2000'   Warranty start date: 2014-01-02T04:06:27   Recertification date: - Instrument Licences   Measurement Modes: [ReflectanceSpot, ReflectanceScan, EmissionSpot, DualReflectanceSpot, DualReflectanceScan]   Licensed functionality: [Has UV LED, Has Wavelength LED, Has Zebra Ruler sensor, Max Ruler Length = 300 mm, Has Indicator LED, Spectral values, Tristimulus, Density]   Button Test   Button: Successful Emission test   Emission calibration: Successful   Prepare the instrument for emission measurement   White measurement: Successful (X=207.131 Y=238.448 Z=218.613)   Gray measurement: Successful (X=77.817 Y=87.016 Z=86.887)   Black measurement: Successful (X=0.279 Y=0.278 Z=0.334)   Red measurement: Successful (X=88.880 Y=47.137 Z=2.722)   Green measurement: Successful (X=80.663 Y=171.680 Z=30.045)   Blue measurement: Successful (X=32.699 Y=16.775 Z=177.161)   Emission: Successful Button Test   Button: Successful Noise Tests   Noise measurements: Successful   Noise result: Successful (electronic noise: 3.430) Reflectance test   Reflectance Spot calibration: Successful (WLS=0.600000024)   Reflectance Spot measurement 1: Successful (96.029, -0.323, 2.735)   Reflectance Spot measurement 2: Successful (96.035, -0.324, 2.724)   Reflectance Spot measurement 3: Successful (96.037, -0.320, 2.719)   Reflectance Spot measurement 4: Successful (96.042, -0.324, 2.722)   Reflectance Spot measurement 5: Successful (96.039, -0.324, 2.723)   Reflectance Spot measurement 6: Successful (96.037, -0.326, 2.731)   Reflectance Spot measurement 7: Successful (96.032, -0.317, 2.732)   Reflectance Spot measurement 8: Successful (96.029, -0.319, 2.726)   Reflectance Spot measurement 9: Successful (96.028, -0.320, 2.728)   Reflectance Spot measurement 10: Successful (96.024, -0.314, 2.736)   Lamp test: Successful (minL=96.024 meanL=96.033 MIT=0.0133199999 CIT=0.0133199999 LOT=1526.94617)   Reflectance drift test: Successful (0.008)   Reflectance Scan calibration: Successful (WLS=0.600000024)   Dual Reflectance Spot calibration: Successful (WLS=0.600000024)   Dual Reflectance Spot test: Successful   Dual Reflectance Scan calibration: Successful (WLS=0.600000024) Positioning Sensor Test   Scan with positioning sensors: Successful (min: -0.252, max: -0.000, total distance: 0.252) *** PASS *** **************************

Directions

Similar products from Spectrophotometers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies