Electrocardiograph Ecg Machine 6 Channel 12 Lead Digital Cardiology +pc Software

US $359.00

  • Beijing , China
  • Aug 14th
                                                                                                         ECG600G 6-Channel 12-Lead Digital Cardiology EKG ECG Machine+PC Software CONTEC                  Introduction ECG600G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management. Function 1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz. 2)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.). 3)Full-digital filter design, anti-baseline drift, AC and EMG interference. 4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads. 5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency. 6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal. 7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency. 8)Sync collection for 12-lead ECG, multiply printing formats, including 26+1(rhythm lead), 26, 34, 34+1(rhythm lead), 43, 43+1(rhythm lead), 62, 62+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc. 9)Display of 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database. 10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes. 11)Print setting, including “Print and save”(print waveform and save case), “Print no save”(only print waveform but not save case), “Save no print”(only save case but not print waveform). 12)AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time. 13)Store more than 1000 cases, convenient for case review and statistic. 14)Multi-language(Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakstan, Russian and Ukrainian) interface and report. Performance Input mode: floating and defibrillation protection Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB) CMRR: >60dB, >100dB(add filter) Time constant: 3.2s Patient leak current: <10µA Calibration voltage: 1mV Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% Noise level: <15µVp-p Input circuit current: 50nA Input impedance: 50M Sampling accuracy: 12-bit Safety classification: class I, type CF and defibrillation-proof applied part Recording mode: thermal printing system Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing. Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing. Manual record: set record according to record format, manually switching leads. Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) Paper size: 80mm(W)20m(L) Sampling frequency: 1000Hz EMG interference filter: 25Hz/35Hz (-3dB) Power frequency filter: AC 50Hz/60Hz(-20dB) Paper speed: Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Accessories Standard: A lead cable A limb electrode A chest electrode A thermal recording paper A power cord An earth wire A user manual Optional: ECG-Sync software+USB cable ECG electrode Bag Conductive gel Physical characteristic Dimension: 315mm(L) 215mm(W) 92mm(H) Weigh: 1.7Kg Buy Safe Product!! The following FDA Disclaimer is required for all eBay listing in  Healthcare category and is included for REFERENCE:  The sale of this item may be subject to regulation by the U.S.  Food and Drug Administration and state and local  regulatory agencies. If the item is subject to FDA regulation,We will verify your status  as an authorized purchaser of this item before shipping of the item.  The model is registered on the Australian Register of Therapeutic  Goods (ARTG) with the code 197923, and certified by FDA  510K Approved of America and CE,TUV of Europe About Us Contec Medical Systems Co., Ltd. (hereinafter referred to as CONTEC) focusing on research, manufacture and distribution of medical instruments, was founded in 1996 as a high-tech company. CONTEC locates in Economic & Technical Development Zone in Qinhuangdao covered an area of 125 acres and building area of over 100000 square meter, which is one of the largest bases for R & D and production of medical devices in China. Contec hopes to cooperate with international companies to supply more innovative design and advanced  technology  products  We sincerely welcome you to become one of our global partners. We are looking forward to establishing a successful business relationship with you.                              Only English user guide, if you need any other language, please contact us!
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Number of Channels 6 Channel
Bundle Listing Yes
ECG & EKG Machine Type Electrocardiograph
Features Printer
Number of Leads 12 Leads
Operation Digital
Model ECG600G
MPN 69450401
Country/Region of Manufacture China
Brand CONTEC
UPC 69450401 0048 5

Directions

Similar products from ECG & EKG Devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies