Endo Ultra Activator Dental Sonic Irrigator 3speed Root Canal Clean 60 Eddy Tips

US $3500

  • Rowland Heights, California, United States
  • Aug 4th
Package List: Depend on the choice you add into your cart. Advantages: 1.Specially design for Difficult root canal cases 2.Streamlined handle, easy to operate 3.Has 3 variable from low to high ,it can be adjusted to your preference. 4.Dual Purpose device: 5.2 Popular colors you could chosse welcome to do OEM/ODM to customise the color you want. 6.Battery changed easily. STORE HOME ALL ITEMS ABOUT US ADD TO FAVS FEEDBACK CONTACT US STORE CATEGORIES Auction Bid All items Orthodontic Supplies Endodontic Supplies Tooth Filling & Supplies Handpiece & Accessories Ultrasonic Scaler&Accessories Dental Machine Tooth Model Root Elevator Dental Impressions Repair/Treatment Auxiliary Dental Clinic & Lab Supplies Wholesale Other Dental Items RECOMMANDATION Orthodontic Super Elastic Niti Arch Wire 200 Wire US$22.49 BUY IT NOW Dental NITI Endo U-FILE Tip Ultrasonic Cleaning File US$10.37 BUY IT NOW Dental Brackets Mini Roth 022 3w/H US$62.98 BUY IT NOW Endo Ultra Activator Dental Sonic Irrigator 3Speed Root Canal Clean 60 Eddy Tips Product Description   Advantages: 1.Specially design for Difficult root canal cases 2.Streamlined handle, easy to operate 3.Has 3 variable from low to high ,it can be adjusted to your preference. 4.Dual Purpose device: 5.2 Popular colors you could chosse welcome to do OEM/ODM to customise the color you want. 6.Battery changed easily.   Package List Main Unit 1 PC Protective Barrier 100 PCS Needle Tips: 2/15  20 PC 4/25  20 PC 4/35  20 PC       1. Indications For user The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm. The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success. 2. Notice 1) Remove the needle tip of EasyDO Activator. If your treatment process is over, please leave it for medical recycling. 2) Please put exhaustively discharged battery into the recycling box. 3Do not submerge the unit in water. 4Do not autoclave the unit. 3. Precautions 1) The EasyDO Activator system is only used by dental professionals. 2) The EasyDO Activator system is comprised of the Hand device and Activator needle tips of various sizes. If the system functions are used correctly, the equipment can maintain a normal operation. It is strictly prohibited to use non-original components, which will damage the equipment and make it unable to work normally. The original components include the Easydo activator hand device, needle tip and protective cover.The Easy smile reference number of the hand device EASYDO Activator-M10821 The reference numbers of the EasyDO Activator Needle tip M10822-015 (Small) M10822-025 (Medium) M10822-035 (Large)   3The handle device provides three speeds sonic motor adjustment options (High, Med, Low). The speed gears switch setting adjustment is ultimately determined by the procedure to be performed, the cliniclan' experience can efficiently complete the clinical task. 4) The handle device don’t require calibration for normal use. 5) All clinical treatment should be performed with Easydo activator protective barrier sleeve that placed over the hand device. 6) In the course of treatment, we should use sterilized and individually packed needle tip, otherwise it will cause root canal infection. 7) It is necessary to use EasyDO Activator system correctly according to treatment specifications and operation manual to prevent injury to patients. 8) Improper using of the hand device may result in broken handle of the equipment and damage of internal components. 9) The EasyDO Activator needle tips and protective sleeve are intended for single-patient use only. Cross contamination may occur to the patient if needle tips and protective barriers are re-used.     4. Warranty information of EasyDO activator 1The EASY IN SMILE company provides users with quality assurance within one year from the date of purchase of this product. In case of any failure due to the defect of Hand device material or production process of the mainframe within this year, the EASY IN SMILE company will provide equipment repair or replacement products. 2The warranty does not include consumables such as needles, batteries, etc. 3If the equipment is damaged due to improper use and maintenance, or maintenance personnel repair or change of spare parts without the authorization of EASY IN SMILE, the warranty policy is invalid. 4Under any condition, neither EASY IN SMILE nor its affiliates are responsible for any special, incidental, or consequential liability resulting from a violation of the warranty policy, contract, or any other legal policy. Such damages include but are not limited to loss of investment, loss of profits, loss caused by wrong use of product functions, etc.; including but not limited to third party claims and increase of service cost caused by any alternative equipment, etc.   5Warranty limitations Content not covered by warranty: -Needle tip -Hand device barrier sleeve -Damage caused by misuse, abuse, neglect of prompt or change of the equipment usage -Normal wear and other external scratches, including scratches, wear, cracks, discoloration or fade. -Battery replacement * Note: If the product is not used for a long time (two weeks or longer), please remove the battery. It also must be removed during transport, for example, during delivery   10) Properly dispose the Activator needles tip and hand device protective barriers in accordance with the local laws and regulations and environmental protection requirements.11) Dispose the battery after being used in accordance with the local laws and regulations and environmental protection requirements, when battery is exhausted. 12) The hand device must be repaired if necessary according to the direction of the manufacturer. 13) Don’t insert needle tip into the hand device. If the equipment is not used for a long time, placing the hand device into packing box is recommended. 14) Remove the battery when the hand device is not used for a long time. 15) The hand device can be kept at the temperature of 0 ~ 55 , relative humidity 0% ~ 75% RH and air pressure750-1060 HPA. 16) The hand device should be keep away from strong electromagnetic interference, which may affect the performance and normal use of hand device. 17) The hand device should be kept away from portable or mobile RF communication devices, which may affect the performance of hand device . 18) The hand device could not be adjacent to or stored with other equipment. In addition, it is necessary to check regularly whether the hand device can work normally. 19) Proper disposal of the hand device is required when the hand piece is deemed no-functional in accordance with local laws and regulations. 6.Product parameters Name EasyDO Activator Model EASYDO Activator-M1082 Function Debridement / disinfection / root canal therapy Use environment Indoor environment; Temperature range: 0 ~ + 55 ; Relative Humidity: 0% ~ 75% RH; Air Pressure: 750-1060 HPA Power Supply DC1.0v~1.5v Battery AA grade LR6, 1.5v mercury-free alkaline dry battery Size L 183mm * W 23mm * H43.1mmGross Weight 124g 7.Operation / Step Preparation: 1) Prepare the root canal to produce a fully tapered shape. 2) Fill pup chamber with NaOCI, EDTA, or final rinse soulution. 3) Select the needle tip that manually fits loosely within 2mm of the working length. 4) Place the barrier sleeve over the complete length of the hand device. 5) Connect the needle tip to the hand device with the barrier sleeve. The activator should snap on firmly, promoting a secure connection with the hand device. 6) Press ON/OFF button for 1 second, you can see the battery power status. If the power is enough, you can continue the treatment. If the power is not enough, you need to replace the battery. 7) Place the attached needle tip into the prepared root canal. 8) Drepress the ON/OFF button to actvate. Switch defaults to high speed upon activation. Depress the 3-speed switch to select medium speed or low speed. 9) Use a pumping action to move the hand device in short 2~3 mm vertical strokes. 10) Hydro dynamically agitate the medical solution for about 30-60 seconds. 11) After washing, use a suction pipe to remove loose debris and sundries from the root canal. 12) Repeat the above steps for each different root canal treatment. * when the clinical procedure has been completed, remove the protective barrier sleeve, remove the needle tip and store it in the medical waste recycling box. The needle tip and protective sleeve are intended for single-patient used only. Other instructions: if the EasyDO Activer hand device has been working for 8 minutes without any operation, or there is no operation after the equipment stops working, it will enter the state of self-protection system and power oFF. If you need it to restart , please depress the ON/OFF switch. 8. Key points of Operation: 5.1POWER OF BATTERY STATUS Depress the " ON / OFF Switch" key for 1 second to observe the "Power Indicator" status around the button of the hand device. 1. If the "Power Indicator" is white, it means the activator system is in full power status; 2. if the "Power Indicator" is red and white, it means the system is in half power status; 3. if the "Power Indicator" is red, it means the system is in power shortage status; 4. If the "Power Indicator" is flashing red, it indicates that the system is on the verge of power failure. 5. Please note if the "power indicator" is flashing red, please replace the battery.   FDA Description Delivery details Terms of sales Payment FAQ FDA Description Photography Cheek Retractor Autoclavable and Durable Lip Opener US$10.71 BUY IT NOW Dental Surgical Zekrya Carbide Tungsten Bur Tool FG Bur US$9.98 BUY IT NOW Super Endo Sonic Endo Irrigator 60 Tips US$56.66 BUY IT NOW Copyright © 2017 easyinsmile-dental. All Rights Reserved.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Easyinsmile
60 Tips free Yes
MPN Does Not Apply
warranty 1 year for Main Unit
Intended Use/Discipline Dental Laboratory, Dentistry, Endodontics
Evenly apply medicine Yes
Country/Region of Manufacture China
UPC Does not apply

Directions

Similar products from Other Medical Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies