Factory Contec Ce Cms-m Multi-function Visual Stethoscope Lcd Backlight,spo2 Ecg

US $109.00

  • qinhuangdao. hebei, China
  • Jan 30th
CONTEC CMS-M Multi-function Visual stethoscope Contact person:Vivian Zhang     Skype:ContecVivian      Tel:+86 18617816016 CMS-VESD Visible CMS600P1 B-Ultrasound PM70 Patient Monitor ECG/NIBP/SPO2/PR/HR KT88-1016 16-Ch EEG CONTEC08A Digital Blood Pressure Monitor CONTEC08C+SpO2 with cuff and probe Adult/child/infant/veterinary Use CMS6000B Patient monitor SP10 Lung Spirometer CMS600H B-ultrasound Animal Use Linear probe CMS800G Twins Fetal Monitor CMS6000C Animal monitor CMS-RSO1 Respiration Monitor MS400 SpO2 Simulator CMS600P2 ultrasound Animal 6.5MHz Transvaginal Probe TLC5000 24hours Holter ECG CMS600B-2 ultrasound Convex Probe ABPM50 Ambulatory NIBP with 3 cuffs CMS600P3 ultrasound Convex probe CONTEC06C Digital Blood Pressure Monitor Description Instructions CMS-M is a kind of multi-functional visual stethoscope It is added with collection ECG waveform function on the basis of the traditional medicinal stethoscope.It can display the heart rate, the pulse oxygen Saturation and pulse rate can also be monitored through SpO2 probe. The product is applicable for family, hospital, private Clinique, community medical treatment.etc. Main features ? Regular stethoscope ? Compact and portable,easy to use ? Display of ECG waveform, heart rate,SpO2 ,pulse rate ,pulse waveform  ? Adjustable screen contrast ? Alarm for SpO2 and pulse rate exceeding limits ? Low power consumption Main Parameters ? Heart Rate measuring range: 30bpm~300bpm ,Accuracy: ±2 bpm or ±2%(select     larger) ? SpO2 measuring range: 0%~100% (the resolution is 1%),Accuracy:   70%~100% :±2% ,below 70% unspecified ? Pulse Rate measuring range: 30bpm~250bpm,Accuracy: ±2 bpm or ±2%(select larger) ? Resistance to surrounding light: The deviation between the value measured in the     condition of man-made light and indoor natural light and that of darkroom is less than ±1%. ? Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be     shown orrectly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%, pulse rate error is ±2 bpm      or±2% (select larger). ? Display : 2.7" LCD  ? Power consumption:

Directions

Similar products from Stethoscopes & Chestpieces

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies