Fda Hand-held Pulse Oximeter Usb Blood Oxygen Pr Hr Monitor +adult Spo2 Probe

US $260

  • Elk grove village,Illinois 60007-4825, United States
  • Aug 22nd
                                                                                                        FDA US STOCK,Handheld Pulse Oximeter HR PR Monitor Adult SPO2 Probe                 Introduction CMS60D Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology in accordance with Capacity Pulse Scanning & Recording Technology, which can be used to measure SpO2 and pulse by finger. It is applicable for use in hospital, oxygen bar, community healthcare and exercise healthcare(It can be used before or after exercise, but not recommended to use during exercising). Features 1.Small in volume, light in weight and convenient to carry. 2.Easy and simple to operate, low in power consumption. 3.With function menu. 4.Display of SpO2 value. 5.Display of PR value and bar graph. 6.Display of pulse waveform. 7.Adjustable screen brightness, PR sound indication. 8.Review function. 9.Clock function. 10.Audible prompt for over-limit and low battery. 11.Battery status indication. 12.Low battery indication. 13.Storage function for SpO2 and PR values, and data stored can be uploaded to PC. 14.Real-time data can be uploaded to PC. 15.External SpO2 probe can be connected. Performance Display mode: color display SpO2 measurement range: 0 % ~ 100 %(resolution: 1 %) Accuracy: 70%~100%: ±2% 0%~69%: unspecified PR measurement range: 30 bpm~250 bpm(resolution: 1 bpm) Accuracy: ±2 bpm or ±2 %, whichever is greater. Measurement performance in weak filling condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4 %. SpO2 error is ±4 %, pulse rate error is ±2 bpm or ±2 %, whichever is greater. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1 %. Power consumption: 100 mA Voltage: DC 3.0 V Power supply: two AA batteries Continuous working time: 44 hours in theory Safety class: internally powered equipment, type BF applied part Physical characteristic Dimension: 110 mm(L) 60 mm(W) 24 mm(H) Weight: about 120 g(including battery) The Fingertip PulseOximeter is registered on theAustralian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE &TUV of Europe.                                                                               
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Oximeter Type Pulse Oximeter with Probe
Brand CONTEC
MPN Does Not Apply
Form Factor Handheld
UPC Does not apply

Directions

Similar products from Pulse Oxymeters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies