Fieldpiece Srl8 Heated Diode Refrigerant Leak Detector With Case Cfc,hcfc,hfc

US $1200

  • Goodyear, Arizona, United States
  • Jan 29th
Fieldpiece SRL8 Heated Diode Refrigerant Leak  Detector With Case CFC, HCFC and HFC Free Expedited Shipping (USPS Priority Mail®) FREE Shipping to all USA, Territories and APO/FPO   User's Manual Product Flyer Competitive Advantages What's Included? Recommended What is It? The SRL8 Heated Diode Refrigerant Leak Detector is designed exclusively to make the HVAC/R Technician's job easier, faster, safer and more efficient. We set out to develop the best heated diode leak detector for HVAC/R. We believe the SRL8 is it. It comes in kit form in a rugged, blow-mold case with all of the extras you don't get from the other guys. (see What's Included?). The Fieldpiece ergonomic standalone design fits naturally in your hand. The ruggedized construction stands up to abuse most other leak detectors can't handle. The 15-hour battery life lets you work all day and then some before recharging. The included vehicle and wall chargers help you during overtime. The MUTE and ZEROing functions allow you to work the way you want to work. The magnetic hanger helps keep the detector out of the way when repairing a leak, but visible enough so you won't leave it on the job. How Does it Work? The SRL8 heated diode refrigerant leak detector triggers on absolute concentration of refrigerant present. Meaning, the closer you get to the leak, the more intensely it will trigger on both the LED display and audio alerts. It zeroes out automatically or can be adjusted manually to zero in on leaks. Simply turn it on, manually or automatically zero, adjust the sensitivity to the desired level and begin testing. Competitive Advantages Why Heated Diode technology? Based on the success of our infrared refrigerant leak detector (model SRL2) and multiple requests from technicians, we decided to develop the best heated diode refrigerant leak detector for HVAC/R. Some technicians like the way heated diode sensors trigger on absolute concentration, meaning the closer you get to the leak, the LEDs and audio alerts increase in frequency because more refrigerant is passing the sensor. The infrared leak detector senses change in refrigerant levels and requires a sweeping motion to pinpoint leaks. IR sensors zero out and stop triggering if kept hovering over a leak. Bottom line: We made the best detector available for the way you like to test. We let you decide which is right for you. Advantages Over Other Refrigerant Leak Detectors Triggers on all CFCs, HFCs, HCFCs and blends. More sensitive to some refrigerants than others. 15-hour rechargeable, user replaceable battery. It lasts almost two full workdays on a single charge (if your hunting down leaks all day). You can also use it while it's hooked up to the wall or vehicle charger. Filter system helps protect the sensor from moisture and other contaminants. The sensor is connected to the body at the other end of the snout. The filter is at the tip of the snout. If you accidentally hit some condensation or oil, the filter swells, shutting off the pull to the sensor and protecting it from failure. Manual or automatic zeroing. It auto zeros every two seconds until a leak triggers the sensor. After that you can manually zero the detector to help further pinpoint leaks.. Up and running in 30 seconds. Some heated elements and corona discharge units take much more time to warm up. UV dyes can take several hours to travel through a running system and can degrade system components. SRL8 - Designed for HVACR Three sensitivity levels from 6.6oz/yr to <0.1oz/yr. Meets new SAE standards. Rugged / Ergonomic Features. Ruggedized boot and it fit's in your hand. Heated Diode Senso lasts up to 5 years (depending on use and exposure). Audible/Visual Alarm. Turn the beep on or off - you decide. 15-hour Battery Charge. Work all day and all night on one charge. Battery life check. See how much charge you have left by looking at the LED display. Non-conductive, Sturdy Probe. Stays where you want it. LED and Audio alerts. Find leaks in noisy environments. Mute: Turn off the sound when you don't want anyone to hear what you're doing. Magnetic Hanger. Hang the unit while you repair the leak. Weighs 14-oz. Tough doesn't have to mean heavy. What's Included Advanced Refrigerant Leak Detector - SRL8 (5) O-rings and 10 replacement filters - RFL2 9-inch Flex-Probe Extension - RFE2 Rigid Extension Probe - RRE2 Blow-Molded Case - ABMK3 Operator’s manual Specifications TECHNICAL SPECIFICATIONS Gases measured: CFC, HFC, HCFC& blends. Sensing element: Heated Diode. Response time: Less than 1/2 second to 1 second. Sensitivity levels: HIGH: better than 0.1 oz/yr. (per SAE standards) MEDIUM: 0.6 oz/year and higher. LOW: 6.6 oz/year and higher. Accuracy: Meets current SAE standards. Calibration: Automatic or manual zeroing. Warm-up time: <30 seconds. Probe Length: 15 inches. (Included extension probes measure 9 inches ea.) Battery Type: 3.7VDC(nominal) rechargeable lithium ion. Battery Life: Approximately 15 hours (fully charged) Limited warranty from Fieldpiece This warranted is against defects in material or workmanship for one years from date of purchase. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss. State laws vary. The above limitations or exclusions may not apply to you. Obtaining Warranty service Call Fieldpiece Instruments at (714) 634-1844 FAX (714) 634-1848 for warranty service. Send the unit back to Fieldpiece Instruments to 1900 E WRIGHT CIRCLE. ANAHEIM, CA 92806 Send proof of date and location of purchase for in-warranty service One year. The meter will be repaired or replaced, at the option of Fieldpiece, and returned via least cost transportation.  
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Fieldpiece
Model SRL8

Directions

Similar products from Leakage Detection Tools

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies