Fireye Ep160, Ep161, Ep163, Ep165, Ep166, Ep170, Ep174 & Ep177 Programmer Module

US $307

  • East Longmeadow, Massachusetts, United States
  • Jun 9th
 This listing is for a Fireye EP160, EP161, EP163, EP165, EP166, EP170, EP174 & EP177 Programmer Module New in Packaging What you will get Fireye EP160, EP161, EP163, EP165, EP166, EP170, EP174 & EP177 Programmer Module New in Packaging This is a Fireye EP160, EP161, EP163, EP165, EP166, EP170, EP174 & EP177 Programmer Module. Description: The Fireye EP160, EP161 (extended MTFI), EP163 (programmable), EP170 and EP174 (early spark termination), EP165, EP166 (pilot stabilization) or EP177 (early spark termination and programmable operating parameters) programmer modules are used with the FLAME-MONITOR Burner Management Control System (P/N’s E100 and E110). Several operational characteristics of the programmer are determined by six (6) dipswitches located on the side of the programmer. These characteristics include forced blower motor start delay (dipswitch 1), extended purge timing (dipswitches 3, 4, 5) and the option requiring the 3-P running interlock circuit to be proven open at the start of the operating cycle (dipswitch 6). Dipswitch 2 is inactive. Models EP163 and EP177 characteristics are programmed via the ED510 Display Module, rather than by dipswitch. The EP160, EP161, EP163, EP165, EP166, EP170, EP174 and EP177 programmers provide start-up programming, safe-start check, and flame monitoring supervision. They insure open damper (high purge) prepurge, proof of low fire position, and fuel valve end switch safety checks. A running interlock circuit on the FLAME-MONITOR system constantly monitors the limit switches, air flow switches, and fuel pressure switches through the programmer. The programmer control is designed to initiate a safety lockout if any of these circuits are open at the improper point in the control cycle. The programmer module will de-energize all fuel valve circuits within four (4) seconds (max.) following a flame failure [two (2) seconds for the EP165 and EP166], or at the end of the pilot trial for ignition period if no flame is detected. An alarm circuit will be energized following a safety lockout. The programmer module includes an RJ45 style connector to interface with an integral or remote alpha-numeric display (P/N ED510). It is also backward compatible with the ED500 display. It includes two (2) additional RJ style connectors to connect to an E500 communication interface in a multi-drop configuration or allow communication via a Modbus protocol. The programmer will also communicate with the E500 via the ED550 cables to provide backward compatibility. The programmer is the heart of the FLAME-MONITOR System and features a plug-in design for ease of installation. It is micro-processor based and stores the burner cycles, burner hours, system hours, and lockout history (with burner cycle and burner hour time stamp) which are accessible via the ED510 alpha-numeric display, E500 Communication Interface, InTouch Wireless Monitoring System or Modbus communications. If replaced, the new programmer card will begin accumulating a new history. Documentation: Fireye EP160 Manual Free shipping in the USA. If you receive your item and it is not to your 100 Percent Satisfaction, please contact us before leaving feedback.  I strive to make sure every transaction is a positive one!  I wanted to reach out and let you know that eBay is changing the way Sellers are rated.  I am not overjoyed with what's happening, but I have to roll with it.  IF you have a problem with my item, I would like you to use the "Contact Seller" link in the listing, or call me.  Please don't open a case.  Cases count against me even if they are resolved. I stand behind my items and will work out any problems that you may have with an item.  So please contact me if you have a problem with an item I have sold you and don't use the eBay Case as a means of communication. International Buyers, Please Note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. These charges are normally collected by the delivering freight (shipping) company or when you pick the item up do not confuse them for additional shipping charges. We do not mark merchandise values below value or mark items as "gifts".  US and International government regulations prohibit such behavior. Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.

Directions

Similar products from Temperature and Humidity Controller Thermostats

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies