Fluke 190m-4 Medical Scopemeter 4 Channel 200mhz Oscilloscope 190m 4 190-204

US $4,495.00

  • Toledo, Ohio, United States
  • Jan 29th
                                                              Content on this page requires a newer version of Adobe Flash Player.                      The Following Items Are Included: Fluke 190M-4 Medical ScopeMeter 4 Channel 200MHz Oscilloscope (BC# 18823)  (4) Voltage Probe Sets (1-Red, 1-Blue, 1-Green, 1-Grey) MA190 Medical Set P/N: 402224012111 Fluke 190M Safety Information Guide International Adapters Battery Pack AC Adapter/Charger USB PC Interface Cable User Manual On CD-ROM Strap For Unit Carrying Case (G)     BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration!   Fluke 190M-4 ScopeMeter 4 Channel 200MHz 2.5 GS/s Color Oscilloscope   This Unit Is The Fluke 190-204 ScopeMeter With Medical Option Installed!   With the combined power of a high-performance oscilloscope, multimeter and paperless recorder in an easy-to-use test tool, the 190M is the one test tool you can rely on to tackle just about any troubleshooting task in the field   Includes Carrying Case & Accessories As Listed Above!     Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty     Fluke 190M-4 Medical Scopemeter The 190M Medical ScopeMeter portable oscilloscope is a high-performance test tool built upon the legacy of Fluke and Fluke Biomedical oscilloscopes in partnership with real customers like you. The 190M is available with choice of two or four channels and offers an unprecedented level of performance, ruggedness, and portability. With the combined power of a high-performance oscilloscope, multimeter and paperless recorder in an easy-to-use test tool, the 190M is the one test tool you can rely on to tackle just about any troubleshooting task in the field. To minimize downtime and repair costs, you need to get to the root cause of problems as quickly as possible. The 190M offers a number of unique features to help you quickly set up the scope and diagnose difficult problems like intermittent events, signal fluctuations or drift. Extend your arsenal of troubleshooting capabilities with the new Fluke Biomedical 190M Medical ScopeMeter portable oscilloscope, designed to meet the demands of field service professionals. Features: Two or four electrically-isolated inputs Fast sampling rate, up to 2.5 GS/s on two channels simultaneously with up to 400 ps resolution Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details (scope mode) Dedicated 5000 count digital multimeter in two-channel model Quad meter measurements via scope BNC inputs in four channel model Connect-and-View™ triggering for intelligent, automatic triggering on fast, slow and even complex signals Frequency spectrum using FFT-analysis High-resolution, non-interlaced video Smart averaging ScopeRecord roll mode gives 30,000 points per input channel and capture waveform sample data for up to 48 hours TrendPlot, trend measurement readings for up to 22 days Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s) Two USB ports make it easy to transfer data to a PC and store unlimited waveforms, screen captures and instrument setups on USB memory devices New high-perfomance Li-ion battery technology delivers the longest battery life on the market Easy-access battery door for quick swaps in the field Security slot locks down oscilloscope with Kensington lock while unattended Environmentally tested to meet IP-51 and withstand 3 g vibration or 30 g shock Specifications: Oscilloscope modes Vertical deflection Number of channels 4 Bandwidth 200 MHz Rise time 1.7 ns Number of scope inputs 4 input channels Channel architecture All inputs fully insulated from each other and from ground Inputs may be activated in any combination Input coupling AC or DC, with ground level indicator Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth Normal/invert/variable On each input channel, switched separately Extended offset Not avalable currently Input voltage CAT III 1000 V/CAT IV 600 V rated, see general specifications for further details Vertical resolution 8 bit Accuracy ± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div Input impedance 1 M? ± 1 %/14 pF ± 2 pF Horizontal Maximum real-time sample rate (sampled simultaneously) 2.5 GS/s (2ch) 1.25 GS/s (4ch) Record length Up to 10,000 samples per channel Time base range 2 ns/div to 4 s/div Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord™ roll mode (see recorder mode) Maximum record length 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ roll mode (see recorder mode) Timing accuracy ± (0.01 % of reading + 1 pixel) Glitch capture  8 ns peak detect on each channel (using real time sampling and data compression, at any timebase setting) Display and acquisition Display 153 mm (6 in) full-color LCD with LED backlight Display modes  Any combination of channels; average on/off; replay Visible screen width 12 divisions horizontally in scope mode Digital persistence modes Off/short/medium/long/infinite and envelope mode Waveform mathematics A + B, A – B, A x B, all with user-selectable scaling of resultant; A versus B (X-Y- mode); frequency spectrum using FFT analysis Acquisition modes Normal, averaged, auto, single shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic pass/fail testing; replay Trigger and delay Source Input A, B or external (via meter input) Input A,B,C or D Modes Automatic Connect-and-View™, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle Connect-and-View™ Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals can be switched off if preferred Video triggering (on ch. A) NTSC, PAL, PAL+, SECAM; includes field 1, field 2 and line select High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz Pulse width triggering (on channel A) Pulse width qualified by time allows for triggering < t, > t, = t, ? t, where t is selectable in minimum steps of 0.01 div or 50 ns Time delay 1 Full screen of pre-trigger view or up to 100 screens (= 1,200 divisions) of post trigger delay Dual slope triggering Triggers on both rising and falling edges alike N-cycle triggering Triggers on Nth occurrence of a trigger event; N to be set in the range 2 to 99 Automatic capture of 100 screens When in oscilloscope mode, the instrument always memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the replay button can be pressed to review the full sequence of screen events over and over. Instrument can be set to trigger on glitches or intermittent anomalies and will operate in baby-sit mode capturing 100 specified events. Replay Manual or continuous replay. Displays the captured 100 screens as a live animation or under manual control. Each screen has date and time-stamp Replay storage Two sets of 100 screens each can be saved internally for later recall and analysis Direct storage of additional sets on external flash memory drive through USB host port Fast Fourier Transform (FFT) frequency spectrum analysis Shows frequency content of oscilloscope waveform using Fast Fourier Transform Window Automatic, hamming, hanning or none Automatic window Digitally re-samples acquired waveform to obtain optimum frequency resolution in FFT resultant Vertical scale Linear/logarithmic (in volts or amps) Frequency axis Logarithmic frequency range automatically set as a function of timebase range of oscilloscope Waveform compare and pass/fail testing Waveform Compare Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope or externally using FlukeView Software. Pass/Fail Testing In waveform compare mode, the oscilloscope can be set to store only matching (pass) or only non-matching (fail) acquired waveforms in the replay memory bank for further analysis Automatic scope measurements V dc, V ac rms, V ac + dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac + dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), phase (between any 2 inputs), pulse width (pos./neg.), duty cycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 ? and 600 ? Advanced power and motor drive functions V/Hz Ratio (190M-2 only), Power Factor (PF), watts, VA, VA reactive, VPWMac and VPWM (ac + dc) for measurement on pulse width modulated motordrives and frequency inverters Advanced functions mAxs (Current-over-time, between cursors); Vxs (voltage over time, between cursors); Wxs (energy, between cursors) Cursor measurements Source On any input waveform or on mathematical resultant waveform (Excluding X-Y-mode) Dual horizontal lines Voltage at cursor 1 and at cursor 2, voltage between cursors Dual vertical lines Time between cursors, 1/T between cursors (in Hz), voltage between markers, rise time with markers, fall time with markers; Vrms between cursors, watts between cursors Single vertical line Min/max and average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT resultant ZOOM Ranges from full record overview to zoom-in up to sample level at any record length Meter Modes Meter inputs Via BNC scope inputs Number of readings Up to 4 simultaneously Maximum resolution 99 counts Input impedance 1 M? ± 1 %/14 pF ± 2 pF Advanced meter functions Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C Voltage Vdc accuracy ± (0.5 % + 5 counts) Vac true rms accuracy 15 Hz to 60 Hz: 60 Hz to 1 kHz: 60 Hz to 20 kHz:  ± (1.5 % + 10 counts) ± (2.5 % + 15 counts) Vac+dc true rms accuracy 15 Hz to 60 Hz: 60 Hz to 1 kHz: 60 Hz to 20 kHz: ± (1.5 % + 10 counts) ± (2.5 % + 15 counts) Voltmeter ranges 500 mV, 5 V, 50 V, 500 V, 1,000 V Resistance Ranges Feature/function not available for this model Accuracy Other meter functions Continuity Feature/function not available for this model Diode test Current (A) A dc, A ac, A ac + dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A Temperature With optional accessories. Scale factors 1 °C/mV or 1 °F/mV Recorder Modes ScopeRecord™ Roll Mode Dual or multiple input waveform storage mode, using deep memory Source and display Any combination of inputs, up to four channels All channels sampled simultaneously Bandwidth 20 MHz or 20 kHz, user selectable Memory depth 30,000 data points, each holding min/max pair of information Min/max values Min/max values are created at samples that are measured at high sample rate, ensuring capture and display of glitches Recording modes Single sweep, continuous roll, Start-on-trigger (through any channel), Stop-on-trigger (through any channel) Stop-on-trigger ScopeRecord mode can be stopped by an individual trigger event or by an interruption of a repetitive trigger signal through any input channel Horizontal scale Time from start, time of day Zoom Ranges from full record overview to zoom in up to sample level, at any record length Memory Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis. Direct storage on external flash memory drive through USB host port ScopeRecord™ Roll mode sample rate and recording timespan Time base range 5 ms/div to 2 min/div Recorded timespan 6 sec to 48 hr Time/division in ‘view all’ mode 0.5 s/div to 4 h/div Glitch capture 8 ns Sample rate 125 MS/s Resolution 200 ?sec to 4.8 sec Trendplot™ Recording Multiple channel electronic paperless recorder graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time Source and display Any combination of scope measurements, made on any of the input channels, or DMM reading (two-channel instruments) Memory depth 18,000 Points (sets) per measurement; each recorded sample point contains a minimum, a maximum and an average value, plus a date and time stamp Ranges Normal view: 5 s/div to 30 min/div In view-all mode: 5 min/div to 48 hr/div (overview of total record) Recorded time span Up to 22 days, with a resolution of 102 seconds Recording mode Continuous recording, starting at 5 s/div with automatic record compression Measurement speed 3 Automatic measurements per second or more Horizontal scale Time from start, time of day Zoom Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail Memory Two multiple input TrendPlot records can be saved internally for later recall and analysis. Direct storage on external flash memory drive through USB host port Cursor measurements: all recorder modes Source Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot) Dual vertical lines Cursors may be used to identify min, max or average value of any datapoint in a record, with time between cursors, time from start or absolute time General specifications Input voltage range Rated maximum floating voltage CAT III 1000 V/CAT IV 600 V (Maximum voltage between any contact and earth-ground voltage level) Maximum probe voltage CAT III 1000 V/CAT IV 600 V (Maximum voltage between any contact and earth-ground voltage level) Maximum BNC input voltage CAT IV 300 V (Maximum voltage on BNC input directly) Maximum voltage on meter input CAT III 1000 V/CAT IV 600 V (Safety designed banana input connectors) Memory save and recall Memory locations (internal) 15 Waveform memories plus 2 recording memories 15 waveform memory locations Stores ScopeTrace waveform data (2 traces each) plus screen-copy plus corresponding setup Two recording memories Each may contain: • a 100-screen replay sequence, or • a ScopeRecord roll-mode recording (two traces), or • a TrendPlot recording of up to four measurements External data storage • On PC, using FlukeView™ Software, or • Direct storage on external flash memory drive (maximum 2 GB) through USB host port Screencopies • On PC, using FlukeView™ Software, or • Internally (in instrument), which can be copied on to external flash memory drive as .BMP-file through USB host port Volatility Measurement data is initially stored in RAM, which is maintained by the main battery with a 30-seconds back-up when battery is exchanged When storing data, this is written in non-volatile flash-ROM Real-time clock Provides date and time stamp information for ScopeRecord, for 100-screen replay sequences and for TrendPlot recordings Case Design Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard Kensington lock supported to lock down instrument when left unattended Drip and dust proof IP 51 according to IEC 529 Shock and vibration Shock 30 g, vibration (sinusoidal) 3 g according to MIL-PRF-28800F Class 2 Display size 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD Resolution 320 x 240 pixels Contrast and brightness User adjustable, temperature compensated Brightness 200 cd/m2 typical using power adapter, 90 cd/m2 typical using battery power Mechanical data Size (HxWxD) 265 mm x 190 mm x 70 mm (10.4 in x 7.5 in x 2.8 in) Weight (including battery) 2.2 kg (4.8 lb) Power Line power Mains adapter/battery charger BC190 included, version depending on country Battery power Rechargeable double capacity Li-Ion battery (included). Battery swappable through easily-accessible battery door at the rear of the instrument Battery charge indicator Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen Battery operating time (with backlight low) Up to seven hours using BP291 Battery charging time 5 hours BP291 Battery power saving functions Auto power-down with adjustable power-down time; auto display off with adjustable power-down time; on-screen battery power indicator Safety Compliance EN 61010-1:2001, Pollution Degree 2; CAN/CSA C22.2, No. 61010-1-04, with approval; UL61010B; ANSI/ISA-82.02.01 Environmental Operating temperature 0 °C to +40 °C; +40 °C to +50 °C Excluding battery Storage temperature -20 °C to +60 °C Humidity 10 °C to +30 °C: 95 % RH Non-condensing 30 °C to +40 °C: 75 % RH Non-condensing 40 °C to +50 °C: 45 % RH Non-condensing Maximum operating altitude Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V; up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V Maximum storage altitude 12 km (40,000 ft) Electro-magnetic-compatibility (EMC) EN 61326 (2005-12) For emission and immunity Interfaces Two USB ports provided. Ports are fully insulated from instrument’s floating measurement circuitry. USB-host port directly connects to external flash memory drive (up to 2 GB for storage of waveform data, complete datasets in which data and setup information is included, instrument settings and screen copies. A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control.   Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.   Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!   We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!   Contact: Test Equipment Store eBay Sales Phone: 1-419-517-6681 Toll Free : 1-800-548-2381     We Ship World Wide!   We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate". Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information. We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.   UPS Ground   United States   USD 0.00 USPS Express Mail International (EMS)   Worldwide   USD 0.00   We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED               Put your listings on autopilot with Kyozou eBay Listing Management Software
Condition:
Seller refurbished: An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details. ...
Brand Fluke
Model 190M-4

Directions

Similar products from Cable Tester Kits

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies