Fluke 43b/003 Handheld Power Quality Analyzer - Mint Condition - Free Ship Usa

US $1,499.99

  • Hemet, California, United States
  • Jun 9th
FLUKE 43B/003 HANDHELD POWER QUALITY ANALYZER - MINT CONDITION - FREE SHIP USA FREE SHIPPING IN THE CONTINENTAL U.S.A. ONLY WE SHIP WORLD WIDE E-MAIL FOR PRICE QUOTE -------------------------------------------------- FLUKE 43B/003 HANDHELD POWER QUALITY ANALYZER - MINT CONDITION RETAILS NEW $3499.99 ------------------------------------------- ONE OWNER - IN MINT CONDITION - LIKE NEW - THIS WAS A BACK UP UNIT FOR A NOW DEFUNCT BUSINESS. USED ONLY TWICE. SCREEN IN MINT CONDITION. THIS ANALYZER HAS BEEN PROFESSIONALLY INSPECTED AND TESTED AND WE GUARANTY THE ANALYZER TO BE AS DESCRIBED. WE OFFER A 14 DAY MONEY BACK GUARANTY IF FOR ANY REASON YOU ARE NOT SATISFIED WITH YOUR PURCHASE SIMPLY PAY RETURN SHIPPING FOR A FULL REFUND.   Features New! NiMH Battery provides extended operating time of 6.5 hours Combines the most useful capabilities of a power quality analyzer, multimeter and scope Calculates 3-phase power on balanced loads, from a single-phase measurement Trends voltage, current, frequency, power harmonics and captures voltage sags, transients and inrush current Monitoring functions help track intermittent problems and power system performance Records two selectable parameters for up to 16 days 20 measurement memories to save/recall screens and data with cursor readings FlukeView software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic Measures resistance, diode voltage drop, continuity, and capacitance Users/applications manual and power quality video to help answer tough questions Complete package with voltage probes and 400 A current clam Get control of power problems The Fluke 43 Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures. All in a rugged handheld package.   Harmonics Voltage, current, and power harmonics Up to 51st harmonic Total harmonic distortion (THD) Phase angle of individual harmonics a   Power Watts, power factor, displacement power factor (cos T), VA and VAR  Voltage and current waveforms   Three phase On-screen graphics show you how to set up 3-phase power measurements   Sags and swells Measurements are always automatically recorded to instantly show changes over time Use cursors to read time and date of sags and swells   Transients Catch voltage transients and waveform distortion down to 40 nS Catch and save up to 40 transients Correlate the cause of transient with time and date stamps   Volts/Amperes/Hertz Voltage and current waveforms True RMS volt p, FlukeView Software and optically isolated interface cable Technical Data Input Characteristics Input impedance 1 M?, 20 pF Voltage rating 1 M?, 20 pF V/A/Hz Display True-rms voltage (ac + dc) Ranges: 5.000 V, 50.00 V, 500.0 V, 1250 V* Accuracy: ±(1% + 10 counts) True-rms current (ac + dc) Ranges: 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA Accuracy: ±(1% + 10 counts) Frequency Ranges: 10.0 to 15.0 kHz Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 CF Crest factor Ranges: 1.0 - 10.0 Accuracy: ±(5% + 1 count) Power Display Watts, VA, VAR 1-phase and 3-phase,3 conductor balanced loads Ranges: 250 W - 1.56 GW Accuracy: ±(4% + 4 counts) Fundamental Power ± (2 % + 6 counts) Total Power PF Power Factor Range: 20 °C to +60 °C; -4 °F to 140 °F Reference temperature: 0 - 1.0 Accuracy: ±0.04 DPF Displacement Power Factor, Cos .F Range: 0.25 - 0.9 Accuracy: ±0.04 Range: 0.90 - 1.0 Accuracy: ±0.03 H2 Frequency Fundamental Ranges: 40.0 to 70.0 Hz Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 Harmonics Display Voltage, Current, Frequency Ranges: Fundamental to 51st harmonic Accuracy:   Fundamental: VA ±(3% + 2 counts) W ±(5% + 2 counts) 2 to 31st harmonic: VA ±(5% +3 counts) W ±(10% +10 counts) 32 to 51st harmonic: VA ±(15% +5 counts) W ±(30% +5 counts) Frequency Fundamental Ranges: 40 Hz to 70 Hz Accuracy: ±0.25 Hz Phase Range: V, A (between Fundamental & Harmonics) Accuracy: ±3? to ±15? Range: W (between Voltage Fundamental & Current Harmonics) Accuracy: ±5? to ±15? K-factor (Current and Power) Range: 1.0 to 30.0 Accuracy: ±10% THD Total Harmonic Distortion Range: 0.00 - 99.99 Accuracy: ±(3% + 8 counts) Sags and Swells Recording times: 4 min to 16 days (selectable) Vrms Actual, Vrms max, min(AC + DC) Ranges: 5.000V, 50.00V, 500.0V, 1250V* Accuracy: Readings ±(2% +10 counts); Cursor readings ± (2% + 12 counts) Arms Actual, Arms max, min (AC + DC) Ranges: 50.00A, 500.0A, 5.000 kA, 50.00 kA Calibration interval 1 year recommended for Class-A, otherwise 2 years Accuracy: ±(2% +10 counts) Transient Capture Minimum pulse width: 40 ns Useful bandwidth input 1: DC to 1 MHz Number of transients: 40 Voltage threshold settings: 20%, 50%, 100%, 200% above or below reference Reference signal: After START, the Vrms and frequency of the signal are measured. From these data a pure sinewave is calculated as reference for threshold setting. Vpeak min, Vpeak max at cursor: 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V Accuracy: ±5% of full scale R, C, Diode, Continuity Resistance ranges: 500.0 ?, 5.000 k?, 50.00 k?, 500.0 k?, 5.000 M?, 30.00 M? Resistance accuracy: ±(0.6% + 5 counts) Capacitance ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF Capacitance accuracy: ±(2% + 10 counts) Diode Ranges: 0 to 3.000 V Diode voltage:   Accuracy: ±(2% + 5 counts) Continuity: Beeper on at < 30 O ± 5 ? Max current: 0.5 mA Temperature: °C or °F Inrush Current Inrush times: 1 s, 5 s, 10 s, 50 s, 100 s, 5 min Current ranges: 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A Cursor readings: A peak max at cursor 1 and cursor 2 Accuracy: ±5% of full scale Time between cursors: 4 to 235 pixels (1 pixel = inrush time/250) Accuracy: ±(0.2% + 2 pixels) Temperature (with accessory) Range: -100 °C - 400 °C Accuracy: ±(0.5% + 5 counts) Scope Display Measurements: dc, ac, ac+dc, peak, peak-peak, frequency, duty cycle, phase, pulse width, crest factor Time ranges: 20 ns/div to 60 s/div Max sampling rate: 25 MS/s Bandwidth Voltage channel [1]: 20 MHz at inputs, 1 MHz with TL24 Leads Current channel [2]: DC to 15 kHz at inputs, 10 kHz with i400s Current Clamp Coupling: AC, DC (10 Hz - 3 dB) Vertical sensitivity: 5 mV/div to 500V/div Vertical resolution: 8 bit (256 levels) Record length: 512 samples per channel Base ranges: 60 S/div to 20 nS/div ± (0.4% + 1 pixel) Timebase modes: Normal, roll, single Pre-trigger: Up to 10 divisions Trigger Source: Input 1 or Input 2 or automatic selection Trigger Mode: Automatic Connect-and-View™, Free Run, and Single Shot Trigger Mode: Automatic Connect-and-View™, Free Run, and Single Shot Connect-and-View: Advanced automatic triggering that recognizes signal patterns Automatically adjusts triggering, timebase and amplitude and displays stable pictures Memories 20 (screens, settings, data) Memories 20 (screens, settings, data) Recording Recording times: 4 min to 16 days (selectable) Parameters: Choose one or two parameters from one of the groups below: Volts/Amperes/Hertz Power: Watts, VA, VAR, PF, DPF, Frequency Harmonics, THD, Volts (Fund. & Harmonic), Amperes (F&H) Watts(F&H) Frequency (H), %(H) of total, Phase(H), KF Temperature Resistance: Resistance, Diode, Continuity, Capacitance Scope: DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -, Phase, Duty cycle + or -, Peak max, Peak min, Peak min-max, Crest Factor Note *Rated EN 61010-1 600 V CAT III CSA Environmental Specifications Operating Temperature 0°C to +50°C Safety Specifications Electrical Safety EN 61010-1 CAT III, 600V. CSA listed Mechanical & General Specifications Size 232 x 115 x 50 mm Weight 1.1 kg Warranty 3 years Battery Life Rechargeable NiMH pack (charger included), 6.5 hrs extended operating time (continuous) Shock & Vibration Mil 28800E, Type 3, Class III, Style B Case IP51 (dust, drip, waterproof) Certain images/photos incorporated into this template are the royalty free property of idlelimey: license Creative Commons 3.0.
ONE OWNER - IN MINT CONDITION - LIKE NEW - THIS WAS A BACK UP UNIT FOR A NOW DEFUNCT BUSINESS. USED ONLY TWICE. SCREEN IN MINT CONDITION. THIS ANALYZER HAS BEEN PROFESSIONALLY INSPECTED AND TESTED AND WE GUARANTY THE ANALYZER TO BE AS DESCRIBED. WE OFFER A 14 DAY MONEY BACK GUARANTY IF FOR ANY REASON YOU ARE NOT SATISFIED WITH YOUR PURCHASE SIMPLY PAY RETURN SHIPPING FOR A FULL REFUND.
Brand FLUKE
MPN Does not apply
Model 43B/003
Country/Region of Manufacture United States
UPC Does not apply

Directions

Similar products from Voltage Monitors & Power Quality Analyzers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies