Fluke 5080a/sc/meg Calibrator - Full Option!!! New!!! With Cal!!!

US $23,500.00

  • United States
  • Jan 29th
For sale is a BRAND NEW Fluke FULL OPTION 5080A/SC/MEG HIGH COMPLIANCE MULTI-PRODUCT CALIBRATOR complete with A2LA accredited calibration. I have blank out the cert no, serial some details to avoid duplication of my listing. This a relatively new model calibration from Fluke at a very competitive price. Inclusive of all standard accessories. This unit also has full options, SCOPE & MEGOHM. This is going to be workhourse any calibration department/lab can get at the fraction of the other models. Full specification can be viewed below: Technical Specifications Voltage DC   Range: 0 to ±1020V   Best 1 Year Specification: ±0.01% of setting Current DC   Range: 0 to ±20.5A   Best 1 Year Specification: ±0.05% of setting Resistance   Range: 0 to 190 MO, 19 values in x1 and x1.9   Best 1 Year Specification: ±0.025% of setting Voltage AC   Range: 1 mV to 1020V 45Hz to 1 kHz, Sine   Best 1 Year Specification: ±0.1% of setting Current AC   Range:29 mA to 20.5A 45 Hz to 1 kHz, Sine   Best 1 Year Specification: ±0.1% of setting DC Power   Range:10.9 mW to 20.5 kW   Best 1 Year Specification: ±0.11% of setting AC Power   Range: 10.9 mW to 20.5 kW 45-65 Hz, PF=1   Best 1 Year Specification: ±0.36% of setting Phase   Range: 0 to ± 179.99° 45 Hz to 1 kHz   Best 1 Year Specification: ±0.25° of setting Frequency   Range: 45 Hz to 1 kHz   Best 1 Year Specification: ±50 ppm of setting   General Specifications Warm up Time   Twice the time since last warmed up, to a maximum of 30 minutes Settling Time   Less than 5 seconds for all functions and ranges except as noted Standard Interfaces   RS-232 and Ethernet Temperature Performance Operating: 0°C to 50°C Calibration (tcal):15°C to 35°C Storage:-20°C to +70°C Temperature Coefficient   Temperature coefficient for temperatures outside tcal ±5 °C is 10 % of the stated specification per °C for temperatures in the range of 0 °C to 35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated specification per °C. Relative Humidity Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C Storage:<95%, non-condensing Altitude Operating: 2,000m (6,500 ft) maximum Non-operating: 12,200m (40,000 ft) maximum Safety Meets EN. 61010-1:2001, CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1: 2004 Analog Low Isolation 20V EMC Meets EN613261:2006. Line Power Line Voltage (selectable): 100V, 120V, 220V, 240V Line Frequency: 47 to 63 Hz Line Voltage Variation: + 10% about line voltage setting Power Consumption 600 VA Calibration Documentation Report of calibration with data included; 17025 accredited report optional Dimensions Height:19.3 cm (7.6 in) Width:43.2 cm (17 in), 44.3 cm (17.5 in) including handles Depth:53.8 cm (21.2 in) Weight (without options) 22 kg (48 lbs.) Absolute Uncertainty Definition The specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated. Specification Confidence Interval 99% This unit is physically location in our Singapore office so shipping would cost a little but with the great discount, its a DEAL NOT TO BE MISSED. All offers welcomed. To keep the shipping low, you may also have the item locally picked yourself or your forwarder.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Fluke
Country/Region of Manufacture United States
Model 5080A/SC/MEG

Directions

Similar products from Process, Temperature & Pressure Calibrators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies