G3za-8a203-flk-utu Omron New Power Controller 8 Channel Free Shipping !!!

US $299.00

  • Westchester, Illinois, United States
  • Mar 8th
Smaller than a Normal Power Controller. Enables low-noise power control in combination with zero-cross SSRs. (See note.) One Controller can control up to 8 SSRs. RS-485 communications to set manipulated variables and heater burnout detection. The Smart FB Library for the G3ZA can also be used. CE Marking Main Upgraded Functions Soft-start function added for lamp heaters. Three-phase optimum cycle control added for three-phase heaters. Combining with special CT for150-A current detection. Note: The G3ZA must be used in combination with an SSR without the zero cross function when the soft-start function is           used. Comparison between the G3ZA and Normal Power Controllers a Ratings Load power supply voltage range 100 to 240 VAC 400 to 480 VAC Power supply voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 85 to 264 VAC Power consumption 16 VA max. Load power supply voltage 100 to 240 VAC 400 to 480 VAC Load power supply voltage range 75 to 264 VAC 340 to 528 VAC Manipulated variable input 0.0% to 100.0% (via RS-485 communications) Current transformer input *1 Single-phase AC, 0 to 50 A (primary current of CT) Single-phase AC, 0 to 150 A (primary current of CT) Trigger output One voltage output for each channel, 12 VDC ±15%, Max. load current: 21 mA (with built-in short-circuit protection circuit) Alarm output NPN open collector, one output Max. applicable voltage: 30 VDC, Max. load current: 50 mA Residual voltage: 1.5 V max., Leakage current: 0.4 mA max. Indications LED indicators Control method Optimum cycle control Soft-start optimum cycle control *2 Three-phase optimum cycle control Ambient operating temperature -10 to 55°C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature -25 to 65°C (with no icing or condensation) Elevation 2,000 m max. Accessories Instruction Sheet *1. CT inputs are provided only on Models with heater burnout detection. *2. Use an SSR without the zero-cross function (G3PA-[]BL-VD) for soft-start optimum cycle control. (Refer to G3PA for        details.) Performance Current indication accuracy Current Range 0 to 50 A, ±3 A 0 to 150 A, ±9 A 0 to 100%, ±6% * (for models with heater burnout detection) Insulation resistance 100 M? min. (at 500 VDC) between primary and secondary Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between primary and secondary Vibration resistance Vibration frequency: 10 to 55 Hz, acceleration: 50 m/s2 in X, Y, and Z directions Shock resistance 300 m/s2 three times each in six directions along three axes Weight Approx. 200 g (including terminal cover) Degree of protection IP20 Memory protection EEPROM (non-volatile memory) (number of writes: 100,000) Installation environment Overvoltage category III, pollution degree 2 (according to IEC 60664-1) Approved standards UL508 (Listing), CSA22.2 No. 14 EN50178 EN61000-6-4 (EN55011: 1998, A1: 1999 Class A, Group 1) EN61000-6-2: 2001 * When measured with percentage selected for the current monitor parameter and the maximum current measurable    with the CT at 100%. Communications Specifications Transmission line connections Multipoint Communications method RS-485 Max. transmission distance 500 m No. of nodes 31 (via multidrop connections) Synchronization method Stop-start synchronization Communications baud rate 9.6, 19.2, 38.4 or 57.6 kbps, Default: 9.6 kbps Transmission code ASCII Communications data length 7 or 8 bits, Default: 7 Communications stop bits 1 or 2 bits, Default: 2 Communications parity Vertical parity: None, even, or odd, Default: Even Flow control None Current Transformer Specifications (Order Separately) Item Specification Model number E54-CT1 E54-CT3 G3ZA-CT150L Max. continuous heater current 50 A 120 A * 150 A Detection current with G3ZA connected 50 A 150 A Dielectric strength 1,000 VAC for 1 min 2,000 VAC for 1 min Vibration resistance 98 m/s2, 50 Hz Weight Approx. 11.5 g Approx. 50 g Approx. 130 g Accessories None Connection terminals (2) Plugs (2) None * The maximum continuous current is 50 A for the G3ZA in combination with the E54-CT3. 
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
MPN G3ZA-8A203-FLK-UTU
Brand Omron

Directions

Similar products from Relay Module Boards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies