Ge Fanus Versamax

US $300.00

  • Bet-Shemesh, default, Israel
  • Jan 29th
 IC200UDR010 28 Point Micro PLC, (16) 24VDC In, (1) 24VDC Out, (11) Relay Out, 24VDC PS IC200UDR228 28 Point Micro PLC, (16) 24 VC In, (1) 24VDC Out, (11) Relay Out, 12/24 VDC PS VersaMax Micro PLCs IC200UDR010 and IC200UDR228 accept sixteen DC inputs and provide one DC output and eleven normally-open 2 Amp relay outputs. The only differences between these modules are their power supplies and the output current rating of their Q1 DC output. Micro-28 IC200UDR010 uses +24VDC nominal input power, and provides a 450mA, 24VDC output. Micro-28 IC200UDR228 uses +12/24VDC nominal input power, and provides a 100mA, 24VDC output. DC Power The DC power supply requires more current at startup voltage (approximately 4 VDC) than at rated input voltage. A minimum of 2.0 A is required to start up the DC power supply. If configured to disable power-up diagnostics, the PLC begins logic solution 100ms after the voltage level of the power supply input reaches and maintains nominal DC power. The power source for the PLC must have enough transient current capability to support the inrush current of the power supply and to maintain an adequate VDC voltage level (see specifications for inrush requirements). DC Inputs The sixteen configurable DC inputs can be used as positive or negative logic standard inputs or up to three High-speed Counter inputs. Inputs are compatible with a wide range of input devices, such as pushbuttons, limit switches, and electronic proximity switches. The Micro PLC’s +24 VDC supply can be used for input devices and to power the DC input circuits at about 7.5 mA per input. The combination of input circuit cu DC Output (Q1) The DC output circuit (Q1) can be configured to be a standard, High Speed Counter, pulse train, or PWM output. Relay Outputs (Q2 – Q12) Eleven Form A relay outputs (SPST-single pole single throw) can control a wide range of load devices such as motor starters, solenoids, and indicators. The switching capacity of each of these circuits is 2 amps. An external source of AC or DC power must be supplied to operate field devices. Relay outputs cannot be used as Pulse Train or PWM outputs rrent and external device current must not exceed 200 mA. Micro PLC IC200UDR010, IC200UDR228 Specifications Weight 500 grams (1.10 lb) Inputs Sixteen 24 VDC positive/negative logic input circuits Outputs Eleven normally-open 2 amp relay circuits and One DC Output (Q1) High-speed Counters Up to four Type A or one Type A and one Type B +24 VDC Output Power Supply 200mA maximum (for input circuits and user devices) Thermal Derating IC200UDR010: none. IC200UDR228: no derating to 45 degrees C. Above 45 degrees C, number of points on at the same time must not exceed 50%. DC Power Specifications Range IC200UDR010: 24VDC -20%, +25% IC200UDR228: 9.2 to 30 VDC Hold-up IC200UDR010: 10ms at 19.2 VDC IC200UDR028: 5ms Inrush Current IC200UDR010: 1 Amp maximum at 30VDC IC200UDR228: 13 Amps at 12VDC, 27 Amps at 24VDC Inrush Time 10mS for 1 A Input Current IC200UDR010: 0.30 Amp typical at 24VDC IC200URD228: 1.1 Amp typical at 12VDC; 0.55 Amp typical at 24VDC Input Power Supply Rating 8W DC Input Specifications Number of Inputs 16 Rated Input Voltage 24 volts DC Input Voltage Range 0 to 30 volts DC Input Current 7.5mA typical Input Resistance 2.8 Kohms Input Threshold Voltage ON: 15VDC minimum, OFF: 5VDC maximum Input Threshold Current ON: 4.5mA maximum, OFF: 1.5mA minimum Response Time 0.5 to 20ms configurable as regular input; 100?s as HSC input Isolation Voltage 1500V RMS field side to logic side, 500V RMS between groups DC Output Specifications Output logic Positive Logic Operating Voltage IC200UDR010: 24VDC / 12VDC / 5VDC; IC200UDR228: 24VDC / 12VDC Voltage Range IC200UDR010: 24 VDC, +20%, -80%; IC200UDR228: 23.5 - 24.5VDC Output Current IC200UDR010: 450mA; IC200UDR228: 100mA Maximum UL Pilot Duty Rating 0.75A at 24 VDC Maximum Resistive Load Rating 0.75A at 24 VDC; 0.5A at 12 VDC; 0.25A at 5 VDC Output Voltage Drop 0.3 VDC maximum Response ON: 0.1ms maximum (24 VDC, 0.2A), OFF: 0.1ms maximum (24 VDC, 0.2A) OFF state leakage 0.1mA maximum Isolation 1500 VAC between field side and logic side, 500 VAC between groups Fuse Output should be fused externally. Otherwise, a load short can damage the
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Fully operational and functions as intended

Directions

Similar products from Breakout Boards, Multiconductor Cables and Other Wiring Accessories

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies