Hi-accuracy 0.05% Current & Voltage Process Calibrator With Frequency Source

US $450.00

  • Shenzhen, China
  • Jun 9th
Note: we'll ship this item via express mail service to USA, Canada, Australia,  New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg,  Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea,Thailand, Malaysia, Indonesia,  Philippine, Singapore. Clients from other countries pls contact us in advance to confirm different shipping charges  before you order. ETX-1815 Function: 1. Source of voltage, current and frequency. 2. Measure of voltage, current, loop current and frequency. 3. Manual stepping and automatic stepping and ramping. 4. Support for PC communication.   Summary of Source and Measure Functions: Function Measure Source DC V 0-30 V 0-10 V DC mV 0-100 mV 0-100 mV DC mA 0-24 mA 0-24 mA Frequency 1.000Hz-99.999kHz 0.00Hz-20.000kHz Others 24V power supply, Step, Ramp.   Specifications: Specifications are based on a one year calibration cycle and apply from +18C to +28 C unless stated otherwise.  All specifications assume a 10 minute warmup period.   1. DC Voltage Measurement Range Maximum measurement range Resolution Accuracy (% of reading + Counts) ETX-1815 ETX-2015 30V 0V-31V 0.001V 0.05+2 0.02+2 100mV -15mV-80mV 0.001mV 0.05+20 0.02+20 80mV-125mV 0.01mV 0.05+2 0.02+2 -10C-18C, +28C-55C temperature coefficient,±0.005%FS/C.  Input resistance: >1M?.   2. DC voltage Source Range Maximum output span Resolution Accuracy (% of reading + Counts) ETX-1815 ETX-2015 100mV -15mV-99.999mV 0.001mV 0.05+20 0.02+20 100mV-125mV 0.01mV 0.05+2 0.02+2 10V 0-11V 0.001V 0.05+2 0.02+2 -10C-18C, +28C-55C temperature coefficient,±0.005%FS/C.  Maximum load: 1mA or 1k? (It should be based on the lower load.)   3. DC mA Measurement Range Maximum measurement range Resolution Accuracy (% of reading + Counts) ETX-1815 ETX-2015 20mA 0-24mA 0.001mA 0.05+2 0.02+2 -10C-18C, +28C-55C temperature coefficient,±0.005%FS/C.  Input resistance: <100?.   4. DC mA Source Range Maximum output range Resolution Accuracy (% of reading + Counts) ETX-1815 ETX-2015 20mA 0-24mA 0.001mA 0.05+2 0.02+2 20mA (Transducer simulation) 0-24mA 0.001mA 0.05+2 0.02+2 -10C-18C, +28C-55C temperature coefficient, ±0.005%FS/C.  Maximum load voltage: 20V, equivalent to voltage of 20mA on 1000? load resistance.   5. Frequency Measurement Range Maximum measurement range Resolution Accuracy (% of reading + Counts) ETX-1815 ETX-2015 100Hz 1-99.999Hz 0.001Hz 0.02+1 0.01+1 1000Hz 100-999.99Hz 0.01Hz 10kHz 1k-9.9999kHz 0.1Hz 100kHz 10k-99.999kHz 1Hz Sensitivity: 10Hz-10kHz, Vp-p>=1V; the rest: Vp-p>=2V. Wave form: 5 counting points should be added to errors of other wave forms. Commercial frequency can be measured directly.   6. Frequency Source Range Maximum output range Resolution Accuracy (% of reading + Counts) ETX-1815 ETX-2015 200Hz 0-200Hz 0.01Hz 0.02+1 0.01+1 2000Hz 0-2000Hz 0.1Hz 20kHz 0-20kHz 1Hz Output amplitude: >=4.5Vp-p; Wave form: Square wave Accessories:   1. Test leads (one set) 2. Alligator clip (one set) 3. One 12V/1A power adaptor  4. PDF manual Optional accessories:  6 R03-model rechargeable batteries 1 Metal Box Communication line
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model etx-1815
Country/Region of Manufacture China
MPN etx-1815
Brand generic
UPC Does not apply

Directions

Similar products from Process, Temperature & Pressure Calibrators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies