High-accuracy 0.02% True Rms Multimeter Thermocouple Rtd Pulse Hz Test Vc189 Usb

US $360.00

  • ??, ???, China
  • Jan 29th
Note: we'll ship this item via express mail service to USA, Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea,Thailand, Malaysia, Indonesia, Philippine, Singapore. Clients from other countries pls contact with us in advance to confirm the different shipping charges before you bid. The item comes with a USB cable and software, can connect with PC.  Characteristics: 1. Measurements: AC voltage, DC voltage, AC current ,DC current, OHM, Frequency, Period, Pulse width,Capacitance, Beep, Diode, dBm, Thermocouple (TC), Thermal resistance (RTD), AC+ DC, AC + Hz measurement, Maximum, Minimum, Average measurement (MAX / MIN / AVG), The relative value measurement (REL_%) 2. Measurements show that 55,000 words, the basic accuracy 0.02% (VC 189) / 0.05% (VC 187) 3. Three measurement rate: FAST, SLOW, SMOOTH, the fastest refresh rate of simulation bar: 14 / sec 4. Manual range or automatic range selection 5. Measuring data show that hold functional (DIS_HOLD) and automatically hold functions(AUTO_HOLD) 6. Peak measurements, 500us peak sampling capture, capable of capturing crest Pulse 7. AC voltage and AC current are true rms measurement, AC voltage bandwidth 20Hz~30KHz(VC 187), 20Hz-100KHz(VC 189), AC current bandwidth 20Hz-30KHz 8. Option 1 ~ 2400 ? reference impedance measurement of decibels 9. Low pass filter function normally by the RP-raising and the frequency of the electrical waveform measurement results 10. Can be configured clamp to measure the large current 11. The eight kinds of thermocouple measurement, the two kinds of heat resistance measurement, high-precision cold-automatic compensation, °C or °F temperature display 12. Large-screen display and more data can be displayed at the same time that is measurements and other information related to the measurement 13. Built-in real-time clock, for the record and provide accurate measurement of time 14. Easy to operate multi-parameter data record: manual records and records of the incident, and easy to query the data records 15. Adopted panel calibration technology, can be done without opening the case calibration 16. Use alkaline batteries, Ni-Hi battery-powered, the battery and fuse can be easily replaced 17. Backlight is automatically closed and automatic power off function 18. Large-screen LCD display, with white LED backlighting 19. The meter can communicate with computer by isolation interface USB 20. Through the friendly interface, users can easily access the data of instrument in a number of parameters, and may be the data storage, processing, management, access to the data tables and other graphics or display 21. Simple man-machine operating, delicate, strongly and suitable for field use Specifications: Measurements Range Resolution DCV 5.0000V 0.0001V 50.000V 0.001V 500.00V 0.01V 1000.0V 0.1V DCmV 50.000mV 0.001mV 500.00mV 0.01mV 2200.0mV 0.1mV ACV 5.0000V 0.0001V 50.000V 0.001V 500.00V 0.01V 760.0V 0.1V ACmV 50.000mV 0.001mV 500.00mV 0.01mV OHM 500.00? 0.01? 5.0000K? 0.0001K? 50.000K? 0.001K? 500.00K? 0.01K? 5.0000M? 0.0001 M? 50.000M? 0.001 M? 500.0M? 0.1 M? DCA 5.0000A 0.0001 A 20.000A 0.001 A DCmA 50.000mA 0.001mA 500.00mA 0.01 mA DCuA 500.00uA 0.01 uA 5000.0uA 0.1 uA 5.0000A 0.0001 A ACmA 50.000mA 0.001mA 500.00mA 0.01 mA ACuA 500.00uA 0.01uA 50000uA 0.1uA FREQ 9.9999Hz 0.0001Hz 99.999Hz 0.001Hz 999.99Hz 0.01Hz 9.9999KHz 0.0001KHz 99.999KHz 0.001KHz 999.99KHz 0.01KHz 9.9999MHz 0.0001MHz 99.999MHz 0.001MHz DUTY 0.1%~99.9% 0.1% PULSE 199.99ms 0.01ms 1999.9ms 0.1ms DIODE 2.2000V 0.0001V CHCNT 500.0? 0.1? CAP 9.999nF 0.001nF 99.99nF 0.01nF 999.9nF 0.1nF 9.999µF 0.001uF 99.99µF 0.01uF 999.9µF 0.1uF 9.999mF 0.001mF 99.99mF 0.01mF TC R -40°C~1760°C 1°C S -40°C~1760°C K -270.0~1370.0 0.1°C E -270.0~720.0 0.1°C J -210.0~850.0 0.1°C T -270.0~400.0 0.1°C N -270.0~1300.0 0.1°C B 400~1800 1°C RTD Pt100 -200.0~850.0 0.1°C Pt1000 -200.0~630.0 0.1°C Other Features: 1. DC Voltage measurement CMRR:50Hz / 60Hz >= 120dB SMRR:50Hz / 60Hz(Rs=1k?) >= 80dB 2. AC Voltage measurement CMRR:50Hz / 60Hz(Rs=1k?) >= 80 dB A residual reading with input shorted, will not affect stated accuracy above 5 % of range. 3. OHM measurement For relative humidity greater than 70 %, resistance accuracy is 0.5 % over 1 M? and 2.5 % over 10 M?. 4. Internal temperature compensation sensor RJC: temperature range: -10 ~ 50°C, compensation error
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model VC189
Country of Manufacture China
MPN VC189

Directions

Similar products from Multimeasuring devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies