Hp 1630d Logic Analyzer W/ Pods

US $1300

  • Manchester, New Hampshire, United States
  • May 30th
YOU WILL RECEIVE  A WORKING 1630D LOGIC ANALYZER SOME DETAILS: Provides state, timing, and system performance analysis in one instrument Timing post-processing Interactive measurements HP 1630 family of logic analyzers consists of three models designed to meet the needs of digital design and test engineers. The A and D models differ only in channel   State AnalysisState listings and waveforms provide displays and windowing of address, data, status, and control line activity.   Selectable display modes include binary, octal, decimal, hexadecimal, ASCII, relocation, user-defined mnemonics, and microprocessor-specific mnemonics. You can assign labels, and display and/or trigger on code in terms of relocatable or absolute addresses, or mnemonics. 25 MHz speed Up to 65 channels 1k Memory Three clocks Demultiplexing Full compare mode Timing Analysis Timing waveform diagrams provide simultaneous display of up to 16 channels, with user-definable labels that speed and simplify data evaluation.  Wide magnification range, unique glitch display, and direct readout of time between cursors let you quickly adjust parameters to match the application. Speeds to 100 MHz Up to 16 channels (HP 1630D) 1k Memory Timing Post-processing Automatic time-interval measurements are provided with X and O cursors, with statistical calculations to enhance accuracy.   A search-and-then-stop mode, which is called post-processing, stops timing data acquisition if your system violates a timing or sequence condition. System Performance Analysis Meeting system throughput requirements often requires a global look at overall system activity. Time interval, event, and module linkage histograms let you view system hardware and software activity or specific modules of code for performance evaluation. Out-of-spec conditions or bottlenecks stand out.  The display shows measurement data, including the minimum, maximum, average, and total measurement time. Time-interval histogram-eight ranges, 1 ms resolution State label histogram-eight labels, maximum count 263-1 Time-position histogram-1023 time buckets, 1.023 ms to 205 ks duration Module linkage histogram-eight definable events, eight links Interactive Measurements The HP 1630A/D/G's interactive measurement capability allows you to determine whether your system problems are software errors or hardware malfunctions. Trigger on state and view timing data Trigger on timing and view state data Time tags for real-time measurements between states (HP 1630G) Preprocessors A wide selection of preprocessors tailors the HP 1630 logic analyzers to specific microprocessors.   Preprocessor interface modules contain circuitry that properly formats data, and they provide connection via a microprocessor socket.  Software supplied with preprocessors performs inverse assembly for state displays in the selected microprocessor's mnemonics. Inverse Assembly Program activity displayed in inverse assembly can save many hours in test and debug.  No more time-consuming or error-prone conversions from hex because now your measurement listings appear just as you wrote them, making them easy to compare to source-code listings. Fast, Reliable Storage of Setups and Data HP-IB and HP-IL are standard on the HP 1630A/D/G. These interfaces allow the logic analyzer to communicate with a variety of computers, test equipment, and peripherals. A small investment in an HP disc drive allows you to store setups and data.  The HP 1630A/D/G can use the HP 9121S/D and HP 9122S/D disc drives as the mass storage device. Hardcopy Output Simplifies Documentation With the HP 2225A ThinkJet printer, you can quickly obtain a copy of any HP 1630A/D/G display. Instead of time-consuming hand documentation or inconvenient photography, simply push the PRINT button.  In seconds, you have a complete record for your lab notebook. HP 1630A: For Eight-bit Analysis With its 35 channels, the HP 1630A is an economical solution for designs involving eight-bit microprocessors, most of which require 24 channels for address and data. The HP 1630A provides a cost-effective solution and uncompromised measurement performance. In addition to state and timing analysis, the HP 1630A also offers system performance analysis with complete time-interval histogramming, glitch triggering and capture, and post-processing. Most state analyzers offer many levels of triggering, and require you to string the levels together to trigger on the precise term of interest.  The HP 1630A provides four powerful resource terms (a, b, c, d) plus the % of each term, and NO STATE and ALL STATES triggering.  You may assign an address, data, or status value to any combination of resource terms.  Each time the HP 1630A captures a bus transaction, it automatically tests to see whether that term is to be stored, and whether it is a trigger point or a restart term.  Therefore, the HP 1630A accomplishes in one level what most other analyzers require three or more levels to accomplish. For designs requiring 16-bit microprocessors, you can easily upgrade your HP 1630A to either an HP 1630 D or HP 1630G.

Directions

Similar products from Logic Analyzer Modules & Spare Parts

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies