Hp Agilent 8590l Spectrum Analyzer 9 Khz - 1.8 Ghz ! Twin Of 8591e , 30 Day Ror

US $1,395.00

  • Fontana, California, United States
  • Jan 29th
cheap shipping worldwide with new  nist calibration and cert  30 day warranty! this  one has no options but a brand new crt. , i can install opt 21 gpib , rs232  or opt 4 precision freq ref or opt 3 card cage if you need it. let me know I can also add the high stability frequency reference option if you need it for an extra fee or the card cage as well . this can also be connected to an external lcd monitor or tv or projector for educational purposes thru the rear monitor connector.  I can also upon request install any one of the following measurement personalities at no extra charge : cdma  phs gsm multband cable tv scalar quasi peak detector(I think it needs opt 103 hardware  to work though) BRAND NEW  NIST traceable CALIBRATION  with certificate and sticker   adjustments made were frequency reference adj,crt,yto,styf, amplitude, etc... . Beware lots of people claim to have their units calibrated, however if it doesnt have actual adjustments ran its not a calibration but merely a performance test and general approval . and in many cases those approvals dont even pass spec! and spec is not that accurate to begin with! Specifications All specifications apply over 0° C to +55° C. The analyzer will meet its specifications after 2 hours of storage at a constant temperature, within the operating temperature range, 30 minutes after the analyzer is turned on, and after CAL FREQ and CAL AMPTD (and for the 8592L CAL YTF) have been run. 1. N = LO harmonic. N = 1 for 8590L and 8594L 2. Frequency reference error = (aging rate x period of time since adjustment + initial achievable accuracy + temperature stability) 3. Mixer Power Level (dBm) = Input Power (dBm) –Input Atten. (dB) 5 Spurious Responses Second Harmonic Distortion 5 MHz to 1.8 GHz (8590L) <–70 dBc for –45 dBm tone at input mixer3 10 MHz to 2.9 GHz (8592L) <–70 dBc for –40 dBm tone at input mixer3 >10 MHz (8594L) >2.75 GHz (8592L) <–100 dBc for –10 dBm tone at input mixer3 (or below displayed average noise level) Third Order Intermodulation Distortion >5 MHz to 1.8 GHz (8590L) <–70 dBc for two –30 dBm tones at >10 MHz (8592L, 8594L) input mixer3 and >50 kHz separation Other Input Related Spurious ?1.8 GHz (8590L) <–65 dBc at ?30 kHz offset, for ?2.9 GHz (8594L) –20 dBm tone at input mixer3 ?18 GHz (8592L) ?22 GHz (8592L) <–60 dBc at ?30 kHz offset, for –20 dBm tone at input mixer3 Residual Responses (Input terminated and 0 dB attenuation) 1 MHz to 1.8 GHz (8590L Opt. 001) <–38 dBmV 150 kHz to 1.8 GHz (8590L) <–90 dBm 150 kHz to 6.5 GHz (8592L) <–90 dBm 150 kHz to 2.9 GHz (8594L) <–90 dBm Display Range Log Scale 0 to –70 dB from ref. level is calibrated; 0.1, 0.2, 0.5 dB/division and 1 to 20 dB/ division in 1 dB steps; eight divisions displayed Linear Scale Eight divisions Scale units dBm, dBmV, dB?V, V, and W Marker Readout Resolution 0.05 dB for log scale 0.05% of ref. level for linear scale Reference Level Range same as amplitude range Resolution 0.01 dB for log scale 0.12% of ref. level for linear scale Accuracy ±0.3 dB @ –20 dBm 0 dBm to –59.9 dBm ± (0.3 dB + 0.01 x dB from –20 dBm) Frequency Response (10 dB input attenuation) 8590L Absolute4 Relative Flatness5 9 kHz to 1.8 GHz ±1.5 dB ±1.0 dB 8592L Preselector peaked in band > 0 Absolute4 Relative Flatness5 9 kHz to 2.9 GHz ±1.5 dB ±1.0 dB 2.75 GHz to 6.5 GHz ±2.0 dB ±1.5 dB 6.0 GHz to 12.8 GHz ±2.5 dB ±2.0 dB 12.4 GHz to 19.4 GHz ±3.0 dB ±2.0 dB 19.1 GHz to 22 GHz ±3.0 dB ±2.0 dB 19.1 GHz to 26.5 GHz ±5.0 dB ±2.0 dB 8594L (dc coupled preselector peaked) Absolute4 Relative Flatness5 9 kHz to 2.9 GHz ±1.5 dB ±1.0 dB Calibrator Output Amplitude –20 dBm ±0.4 dB 8590L Opt .001 +28.75 dBmV ±0.4 dB Video Bandwidth Range 30 Hz to 1 MHz in 1, 3, 10 sequence Stability Noise Sidebands (1 kHz RBW, 30 Hz VBW and sample detector) >10 kHz offset from CW signal ?–90 dBc/Hz + 20 Log N1 >20 kHz offset from CW signal ?–100 dBc/Hz + 20 Log N1 >30 kHz offset from CW signal ?–105 dBc/Hz + 20 Log N1 System-Related Sidebands >30 kHz offset from CW signal ?–65 dBc + 20 Log N1 Comb Generator Frequency 8592L 100 MHz fundamental frequency Accuracy ±0.007% Amplitude Specifications Amplitude Range 8590L, 8592L, 8594L Displayed Average Noise Level to +30 dBm 8590L (Opt. 001) Displayed Average Noise Level to +75 dBmV Maximum Safe Input Level (Input attenuator ?10 dB) Average Continuous Power +30 dBm (1 W) 8590L (Opt. 001) +75 dBmV(0.4 W) Peak Pulse Power 8590L +30 dBm (1 W) 8590L (Opt. 001) +75 dBmV (0.4 W) 8592L, 8594L +50 dBm (100 W) for <10 ?s pulse width and <1% duty cycle, input attenuation ?30 dB dc 8590L 25 Vdc 8590L (Opt. 001) 100 Vdc 8592L 0 Vdc 8594L 0 V (dc coupled) 50 V (ac coupled) Gain Compression >10 MHz ?0.5 dB (total power at input mixer3 = –10 dBm) Displayed Average Noise Level (Input terminated, 0 dB atten., 30 Hz VBW, 1 kHz RBW, sample detector) 8590L 400 kHz to 1.5 GHz ?–115 dBm 1.5 GHz to 1.8 GHz ?–113 dBm 8590L (Opt, 001) 1 MHz to 1.5 GHz ?–63 dBmV 1.5 GHz to 1.8 GHz ?–61 dBmV 8592L 400 kHz to 2.9 GHz ?–112 dBm 2.75 GHz to 6.5 GHz ?–114 dBm 6.0 GHz to 12.8 GHz ?–102 dBm 12.4 GHz to 19.4 GHz ?–98 dBm 19.1 GHz to 22 GHz ?–92 dBm 8592L (Opt. 026) 19.1 GHz to 26.5 GHz ?–87 dBm 8594L 400 kHz to <5 MHz ?–107 dBm 5 MHz to 2.9 GHz ?–112 dBm Resolution Bandwidth Switching Uncertainty (Referenced to 3 kHz RBW, at ref. level ) 3 kHz to 3 MHz RBW ±0.4 dB 1 kHz RBW ±0.5 dB Linear to Log Switching ±0.25 dB at ref. level Display Scale Fidelity Log Maximum Cumulative 0 to –70 dB from ref. level ± (0.4 dB + 0.01 x dB from ref. level) Log Incremental Accuracy 0 to –60 dB from ref. level ±0.4 dB/4 dB Linear Accuracy ±3% of ref. level This is an 8590L   spectrum analyzer with a range of 9 khz to 1.8 ghz. it is Identical to the 8593e in every way except the motherboard does not accept upgrades via pci slot and it does not come with a card cage standard. however I can add the card cage (opt 3 ) for only an extra 100$ thus converting it to an 8591E . This has been fully  tested with my signal generator and  works flawlessly with no issues .  warranty will be for exchanges within 30 days!. I have thoroughly tested all of the functions and it passes all my freq response ,amplitude accuracy , noise-floor sensitivity,flatness, attenuator, and stability tests  flawlessly within spec and is guaranteed to recalibrate with no issues! .the waveform even at super high frequencies with low spans, on this unit has excellent shape with no spikes at low spans / bandwidths. you may be able to  find one cheaper on ebay but not one this thoroughly tested or freshly calibrated and realigned . chances are that they will not be able to calibrate without repairs. even if they are offering warranty, Its good odds that there is an issue or they are hoping you wont send it in for cal because it will not calibrate.  Im also including a free 32 kb memory card as well (100$ value) upon request All buttons, knob, outputs , and inputs  and  both ref sources(rear 10 mhz ref and front 300mhz  cal out ref) work great. crt is in perfect condition with no screen burn or  significant sign of aging. Its still super bright These units dont need to be sent in for cal very often like the 6 series because it has its own built in frequency and amplitude calibration that you can run anytime.  No errors show when powered up, or while  running all the internal tests , passes confidence test and internal self cal flawlessly . amplitude accuracy flatness is less than .5 db deviation across the spectrum. frequency accuracy has been adjusted and is now dead on accurate even at 20 khz spans at 1.8 ghz. I accept Paypal ( I prefer E-check funding if possible, Contact me for information on e-check funding thru paypal) IF YOU HAVE ANY QUESTIONS AT ALL FEEL FREE TO CONTACT ME (I AM VERY FLEXIBLE AND EASY TO WORK WITH : INCLUDING SHIP-TO ADDRESSES , BUY IT NOW PRICES ,FREE EXTRA ITEMS INCLUDED ,etc...)  Read my 100 Percent Positive FEEDBACK! My feedback says it all! I may be willing to reduce the buy it now price if you are a serious buyer. Just message me.   For information on how you are protected as a buyer for my auctions go to this site: http://pages.ebay.com/help/buy/protection-programs.html For test equipment I am the largest used Stanford Research Systems dealer in the world. I am also known for my HP / Agilent spectrum analyzer and function generator sales as well.  For test equipment I am very knowledgeable with SRS  and HP agilent  equipment : pricing , testing,reconditioning,  and fixing basic issues. Every price that is listed is a price that the same unit sold for before at least  a few times. I am not like the other dealers who list for rediculous prices that no one has ever bought it for in hopes they can make themselves rich. All my prices for musical instruments and scientific electronic test instruments are fair going rate prices. Please be aware that it takes quite a bit of time and effort to get a shipping quote so please be considerate of the seller if you are not ready to buy.  Generally worldwide shipping is really cheap compared to other sellers because I have a 50% discount with fedex priority express thru my friend,  I ship anywhere in the world  !!!! Please email me your address for shipping quote if outside the USA .I fully insure all Items  and pack everything extremely well! Also If you buy the item>  please send your address in this format: Name: Street address: City: State/Province: Area code/zip Code: Country: Phone Number :   Make sure you send your phone number! it is required for national and international shipping! :  Pickup is completely fine as well> I am located 50 minutes from Salt Lake City UTAH and Have another house In southern California.                

Directions

Similar products from Spectrum Analysis Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies