Laboratory Dispensers Bottle-top Autoclavable, Adjustable Volume 10.0 - 50.0 Ml

US $210

  • Palm Desert, California, United States
  • Jan 30th
Brand New  OXFORD Continuously Adjustable Bottle-Top Dispenser 10.0-50.0 ml (P/N 8885600059) (As pictured) or your choice of the following: 0.04 - 0.8 ml (P/N 8885500507), 0.2 - 1.0 ml  (P/N 8885610000) 0.4 - 2.0 ml (P/N 8885600018), 5.0 - 25.0 (P/N 8885600042)  IF YOU ARE LOOKING FOR FIXED VOLUME DISPENSERS: We have these in stock: 0.2 ml P/N 8885105208 1.5 ml P/N 8885105703 2.5 ml P/N 8885105901 3.0 ml P/N 8885106008 4.0 ml P/N 8885106107 5.0 ml P/N 8885106206 10.0 ml P/N 8885106305 OXFORD BOTTLEMATE BOTTLE-TOP DISPENSER- The BOTTLEMATE is chemically inert, permitting it to be used with alkalis, solvents and acid, except Hydrofluoric Acid. - A recycling hole on the top of the threaded base of 1ml, 2 ml, 5ml and 10 ml model permits priming of the extension dispensing tube without loss of reagent.  A hole on the top of the threaded base of 25 ml and 50 ml model can be used only as a receptacle of the extension dispensing tube during storage but not for recycling. - Optional bottle-top adaptors are available with which the BOTTLEMATE can be attached to the threaded neck of most standard reagent bottles. - EFTE coated ceramic plunger (1ml, 2ml, 5ml and 10 ml models) provides smooth operation. - The glass cylinder is protected with dual plastic sleeves. - The Teflon extension dispensing tube provided permits liquid to be dispensed without moving either the BOTTLEMATE or the recptacle. - The BOTTLEMATE is autoclavable at 121 deg. C or below. SPECIFICATIONS Low Volume Setting: Accuracy: +-2.0% Reproducibility: <= 0.3% High Volume Setting: Accuracy: +-1.0% Reproducibility: <= 0.2% Cat. No. Volume Range Increments Size of Bottle (Included) 8885-600000 0.2 - 1.0 ml 0.05 ml 270 ml 8885-600018 0.4- 2.0 ml 0.1 ml 270 ml 8885-600026 1.0 - 5.0 ml 0.1 ml 470 ml 8885-600034 2.0 - 10.0 ml 0.25 ml 1000 ml 8885-600042 5.0 - 25.0 ml 0.5 ml none 8885-600059 10.0 - 50.0 ml 1.0 ml none 1 ml, 2 ml, 5 ml and 10 ml BOTTLEMATE fits reagent bottle with 28 mm threads and is supplied with a glass bottle as shown above, one each of 25 mm,  33 mm and 45 mm bottle-top adaptor, a dispensing nozzle, an extension dispensing tube, a dispensing nozzle cap, two inlet tubes and a small wrench. 25 ml and 50 ml BOTTLEMATE fits reagent bottle with 33 mm threads and is supplied with one each of 38 mm and 45 mm bottle-top adaptor, a dispensing nozzle with a holder, an extension dispensing tube, a dispensing nozzle cap, two inlet tubes and a small wrench, but no bottle is included. PARTS AND MATERIALS (1 ml, 2 ml, 5 ml and 10 ml) 1.  Plunger Handle (Polypropylene) 2. Plunger (ETFE - coated Aluminun Oxide) 3. Outer Sleeve (TPX) 4. Inner Sleeve with Scale (Polypropylene) 5. Guide Ring for Inner Sleeve (Polypropylene) 6. Cylinder (Pyrex Glass) 7. Set Screw (Chrome plated brass) 8. Volume Indicator (Stainless Steel) 9. Outlet Valve Seal (Teflon) 10. Dispensing Nozzle Connector (CTFE) 11. Dispensing Nozzle (Teflon) 12. Dispensing Nozzle Cap (Polypropylene) 13. Outlet Valve (Tefzel, Aluminum Oxide & Platinum Iridium) 14. Threaded Base (Tefzel) 15. Inlet Valve (Tefzel, Aluminum Oxide & Platinum Iridium) 16. Inner Tube Connector (CTFE) 17. Inner Tube (Teflon) 18. Priming Hole Cap (Polypropylene) 19. Extension Dispensing Tube (Teflon & Polypropylene) 20. Wrench (Stainless Steel) 21 Bottle-Top Adaptor (Polypropylene) PARTS AND MATERIALS (25 ml and 50 ml) 1. Plunger Handle (Polypropylene) 2. Plunger (Pyrex Glass) 3. Outer Sleeve (TPX) 4. Inner Sleeve with Scale (Polypropylene) 5. Guide Ring for Inner Sleeve (Polypropylene) 6. Cylinder (Pyrex Glass) 7. Set Screw (Chrome plated brass) 8. Volume Indicator (Stainless Steel) 9. Outlet Valve Seal (Teflon) 10. Dispensing Nozzle Holder (Polypropylene) 11. Dispensing Nozzle Stoppers (Polypropylene) 12. Dispensing Nozzle (Teflon) 13. Dispensing Nozzle Cap (Polypropylene) 14. Outlet Valve (Tefzel, Aluminum Oxide & Platinum Iridium) 15. Threaded Base (Tefzel) 16. Inlet Valve (Tefzel, Aluminum Oxide & Platinum Iridium) 17. Inner Tube Connector (CTFE) 18. Inner Tube (Teflon) 19. Exension Dispensing Tube Receptacle Cap (Polypropylene) 20. Extension Dispensing Tube (Teflon & Polypropylene) 21. Wrench (Stainless Steel) 22. Bottle - Top Adaptor (Polypropylene) OPERATION: 1.  Attach the dispensing nozzle onto the outlet valve by tightening the dispensing nozzle connector (1 ml, 2 ml, 5 ml & 10 ml) or the dispensing nozzle holder (25 ml and 50 ml) firmly so that the open end of the dispensing nozzle of 25 ml and 50 ml faces vertically downwards.  When attaching the dispensing nozzle of the 25 ml and 50 ml model, place the dispensing nozzle stoppers in correct direction. 2.  Attach the inlet tube onto the inlet valve by tightening the inlet tube connector firmly.  (Incomplete tightening causes air to leak into the cylinder. 3.  When using a reagent bottle other than the one provided, select the bottletop adaptor appropriate to the bottle and cut the spare inlet tube to the correct length for the bottle. 4.  Set the volume indicator the desired volume and lock it by tightening the set screw.  Attach the BOTTLEMATE to the bottle. 5.  Remove all air bubbles in the glass cylinder and fill the dispensing nozzle with liquid by pumping the plunger several times using short strokes.  It is recommended to hold the instrument tilted so that the outlet valve faces upward in order to make priming easier.  When using the extension dispensing tube on 1 ml, 2 ml, 5 ml and 10 ml, insert the end of the tube into the priming hole on top of the threaded base.  This allows "no waste" recycling of the liquid while priming.  In order to ensure safe priming with the extension dispensing tube make sure that the end of the tube is inserted far enough so that the tube end can be seen through the bottle.  25 ml and 50 ml model does not have facility of "no waste" recycling of the liquid.  Use a hole on top of the threaded base only as the receptacle of the end of the extension dispensing tube when storing. 6.  Touch the end of the dispensing nozzle (or extension dispensing tube) to the inside wall of the receptacle. 7.  Gently pull the plunger up as far as it will go to draw the liquid into the cylinder, and gently depress the plunger as far as it will go to deliver the preset volume of the liquid. 8.  When the extension dispensing tube is used, keep the end of the tube inserted into the priming hole while the instrument is not being operated. STERILIZING; All parts are autoclavable without dismantling at 121 deg. C or below pressure of one atmosphere.  Use the instrument after it has cooled to room temperature.  If the outlet or inlet valve has loose after autoclaving, tighten the sterilized wrench before operating the instrument.   Water may condense between the inner and outer sleeves when using some model autoclaves.  You may want to losen the outer sleeve by turning counter-clockwise and lifting .  This will limit possible condensation. On Nov-01-14 at 13:01:09 PDT, seller added the following information: Every buyer gets a MyStoreRewards invitation for cash back FREE! Sellers: Add a FREE map to your listings. FREE!
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Oxford
MPN 8885-600059 8885600059
Model Dispensers, Bottle-Top
Country/Region of Manufacture Japan

Directions

Similar products from Medicine Droppers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies