Lithonia Eac Lc Ft 2.2 Kva Fast Transfer Ac Power Inverter Ups Dc Ac New $6999

US $6,999.00

  • Bonita Springs, Florida, United States
  • Jan 29th
LITHONIA  EAC FT 2.2 KVA  1 Phase Fast Transfer AC Power System NEW !!!! PWM DC TO AC UPS. THIS IS PWM MODULATED BY A MICROPROCESSER.... NEW PRICE BE QUICK!!!!! INTENDED USE — An off-line AC power system for the emergency operation of HID, incandescent and fluorescent emergency lighting loads that provides full light output for 1-1/2 hours of use. and fluorescent emergency lighting loads that provides full light output for 1-1/2 hours of operation.NEW IN THE CRATE...  NEVER INSTALLED! MANUFACTURED 2007. THIS HAS BEEN IN A CRATE IN THE WAREHOUSE. IT HAS SOME SHELF WEAR TO THE METAL CABINET. VERY MINOR.... THE FRONT DOOR IS A LITTLE CROOKED. ALL THE INSTALLATION MANUALS ARE INCLUDED.! THERE ARE NO BATTERIES INCLUDED. IT REQUIRES 6 .  PN # BAT-CG12105 CHECK OUT MY PICTURES. ONE OF THEM SHOWS THE SPECS!!!! MAKE US AN OFFER!!!!! HERE IS SOME DATA FROM THE INTERNET. YOU CAN GO TO THE MANUFACTURER FOR MORE INFO! EAC FT AC Power Systems Intended Use An off-line AC power system for the emergency operation of HID, incandescent and fluorescent emergency lighting loads that provides full light output for 90 minutes of operation. Construction Free-standing NEMA Type 1 cabinet. Microprocessor-controlled PWM inverter with IGBT technology allows for universal compatibility. FT has a 65K amp inrush current rating. Sinusoidal output waveform has <3% THD. Off-line uninterruptable system has 2-millisecond transfer time. Standard circuit protection: low-voltage disconnect, short-circuit protection, current-limiting, fused-battery protection, brownout protection, input circuit breaker. Standard RS232 diagnostic interface. Listings UL Listed (standard) for 90 minutes of emergency operation. Output ratings: 1,500 VA to 16,700 VA. Single- phase system. FEATURES & SPECIFICATIONS INTENDED USE — An off-line AC power system for the emergency operation of HID, incandescent and fluorescent emergency lighting loads that provides full light output for 1-1/2 hours of operation. CONSTRUCTION — Inverter: Solid-state, pulse width modulated inverter, utilizing IGBT technology. Off- line uninterruptible system has 2-millisecond transfer time. 1500 to 16700 VA output ratings available. Sinusoidal output waveform has <3% maximum Total Harmonic Distortion for linear load. Operating efficiency is 97% at full load. Input: 120V or 277V input. Other voltages available on request. Synchronizing slew rate is 1 Hz per second nominal. Harmonic distortion <10%. 65KAIC. Output: 120V or 277V output. Other voltages available on request. Fuse protected. Output frequency is 60Hz and is ±0.05Hz during emergency mode. Load power factor is 0.5 lag to 0.5 lead. Cabinet: Free-standing NEMA Type 1. Custom manufactured. 14 gauge steel cabinet with hinged lockable doors. Modular design enables versatile installation. Systems using standard lead calcium batteries that are 4.8 KVA and below are self-contained. Larger systems (6.0 KVA and above) require external, stackable battery cabinets. Cooling: Forced air during emergency mode. Conduit entry through 2” knockouts on top or left side. Battery: Available with maintenance-free, sealed lead-calcium or wet nickel-cadmium batteries. Ambi- ent operating temperature limits are minimum 32°F and maximum 100°F, depending on battery type. Discharge cycle of 90 minutes at full load with fully charged batteries. Extended run times available. Charger: Microprocessor controlled for various battery types and temperature compensating (recharge per UL924 spec). Standard 24-hour battery recharge. Protection: Input circuit breaker standard. Overload capacity is 125% for five minutes. Low-voltage battery disconnect, short-circuit proof, current- limiting, fused battery circuit, reverse polarity, brownout protection standard. Standard supervision/display panel: Programmable self-diagnostic testing for 5 minutes monthly and 90 minutes annually. Microprocessor controlled 2 x 20 character display with touch pad (4 x 4) controls, functions, and data logging. LCD meter panel displays input voltage, output voltage, battery voltage, battery current, output current, Power Systems EAC FT FAST-TRANSFER AC POWER SYSTEM output VA, temperature, and inverter wattage. Five LED indicators display utility present, battery power, battery charging, system ready, and fault. Standard RS232 diagnostic interface. Alarm functions: One audible alarm will indicate high/low battery charger fault, near low battery, low battery, load reduction fault, output overload, high/low AC input volts, high ambient temperature, inverter fault, output fault, and optional circuit breaker trip. LISTINGS — UL listed. Meets UL 924, NFPA 101, NFPA 70, NEC and OSHA. WARRANTY — One-year full warranty within the 48 contiguous states on system electron- ics. Battery warranty details listed on back. System must be installed within 180 days of battery shipment or warranty will be void. Two-year warranty on systems electronics avail- able with purchase of FSP (factory start-up program). Complete warranty terms located at Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice.

Directions

Similar products from Power Regulators & Uninterrupted Power Supplies

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies