Masimo Rad-5v Spo2 And Heart Rate Monitor With Alarms And Memory / Unused

US $110

  • Monrovia, California, United States
  • Mar 7th
 MASIMO RAD-5v PORTABLE SpO2 AND HEART MONITOR  IEC / UL / CS CLASSIFIED  /  NEW / UNUSED  SETTABLE ALARMS / MEMORY / DIGITAL DISPLAYS  COMPLETE WITH FINGER SENSOR & CABLE, OPERATORS MANUAL, FRESH BATTERIES  U.S. SHIPPING ADDRESS AND PAYPAL ONLY  /   FREE SHIPPING  PAYMENT DUE WITHIN 4 DAYS OF WINNING BID.  Info from Masimo : The accuracy and reliability of Masimo SET pulse oximetry in a compact device, perfect for spot-check and triage. > Masimo SET® technology is scientifically and clinically proven to provide accurate pulse oximetry measurements during motion and low perfusion > Lightweight, convenient handheld device with a long battery life—over 30 hours on 4 AA batteries > FastStart™ allows for rapid measurement at start-up > Perfusion Index (PI) indicates arterial pulse signal strength > Signal I.Q.® (SIQ) bar for signal identification and quality indication during motion and low signal to noise situations > Audible and visual alarms for Sensor Off and Low Battery performance measurement range SpO2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 – 100% Pulse Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 – 240 (bpm) Perfusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.02% – 20% saturation accuracy Saturation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70% to 100% No Motion Adults, Pediatrics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3 digits Neonates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3 digits Motion Adults, Pediatrics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±2 digits Neonates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3 digits Low Perfusion Adults, Pediatrics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±2 digits Neonates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3 digits pulse rate accuracy Pulse Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 – 240 bpm No Motion Adults, Pediatrics, Neonates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3 digits Motion Adults, Pediatrics, Neonates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±5 digits Low Perfusion Adults, Pediatrics, Neonates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3 digits resolution Saturation (%SpO2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1% Pulse Rate (bpm). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 bpm electrical batteries Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 AA Alkaline Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . over 30 hours environmental Operating Temperature. . . . . . . . . . . . . . . . . . . . . . . . 32°F to 122°F (0°C to 50°C) Storage Temperature. . . . . . . . . . . . . . . . . . . . . . . -40°F to 158°F (-40°C to 70°C) Operating Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . 5% to 95%, non-condensing Operating Altitude. . . . . . . . . . . . . . . . . . . . . . . 500 mbar to 1060 mbar pressure -1000 ft to 18,000 ft (-304 m to 5,486 m) physical characteristics dimensions Handheld. . . . . . . . . . . . . . . . . . . . . . . 6.2” x 3.0” x 1.4” (15.8 cm x 7.6 cm x 3.6 cm) weight Handheld. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 oz (0.32 kg) modes Averaging mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 seconds Sensitivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal alarms Sensor condition, system failure and low battery alarms High Priority. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 799 Hz tone, 5 pulse burst, pulse spacing: 0.250s, 0.250s, 0.500s, 0.250s, repeat time: 10s Low Priority. . . . . . . . . . . . . . . . . . . . . . . . . 432 Hz tone, 3 pulses, repeat time: 5s Alarm Volume. . . . . . . . . . . High Priority: 75 dB (max), Low Priority: 75 dB (max) display/Indicators Data display. . . . . . . . . . . . . . . . . . . . . . . . . . . . % SpO2, pulse rate, perfusion index, alarm status, alarm silenced status, Signal IQ/pleth bar, battery status Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED compliance EMC Classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC 60601-1 2, Class B Equipment Classification. . . . . . . . . . . . . . . . . . . . . . . IEC 60601-1-1 / UL 60601-1 Type of Protection. . . . . . . . . . . . . . . . . . . Internally powered (on battery power) Degree of Protection-Patient Cable. . . . . . . . . . . . . . . . . . . Type BF-Applied Part Rad-5v Mode of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spot Chec
NEW AND UNUSED / PURCHASED AND STORED 3 YEARS AGO / WITH OPERATING MANUAL.
Brand Masimo
Model RAD-5v

Directions

Similar products from Pulse Oxymeters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies