Medical Oxygen Sensor O2 Cell Compatible Maxtec Max-12 Psr-11-917-m Oom202 M-04

US $79.99

  • Izhevsk, Udmurtiya, Russian Federation
  • Jan 30th
Medical oxygen sensor O2 cell Compatible Maxtec MAX-12 PSR-11-917-M OOM202 M-04 Measurement Range: 0 to 100 Vol.% Expected Operating Life: ~ 1,000,000 Vol.% h Sensor Lifetime: < 6 years @ ambient air Electrical Connector: 3-pin Molex? gold plated Initial Output Signal: 12.5 to 16.5 mV @ dry ambient air Response Time t90: < 12 s Drift: < 1 % Vol. O2/month @ air, averaged across 12 months Operating Temperature: 10 to 40 °C Pressure Range: 700 to 1250 hPa Linearity Error: ; 3 % @ 100 % O2, applied for 5 min Zero Offset Voltage: ; 200 ?V in 100% N2, applied for 5 min Repeatability: ± 1 % Vol. O2 @ 100 % O2, applied for 5 min Influence of Humidity: - 0.03 % rel. O2 reading per % RH Recommended Load Resistor: >= 10 kOhm Temperature Compensation: NTC Interferences: according to DIN EN ISO 21647 and ISO 7767 Weight: approximately 24 g Material in Contact with Media: PA, PPS, PTFE, stainless steel Compatible Analytical Industries PSR-11-917-M  Bird Products Corp. Avea ventilator  Ceramatec CAG-12  Cherion R-24  CityTechnologies MOX-01, MOX-9  EME Infantflow  EnviteC OOM202  Hamilton Medical Arabella, Galileo, Raphael, Aladdin  Hill-Rom / Airshields R-24  Hudson RCI V-12  Infrasonics Adult Star, 60116  Integral Process 65016  IT-Gambert M-04  Maxtec MAX-12  Mercury Medical 10-103-06  MSA 472062, 470644  Neumovent Graph,  Ohmeda General Electric (GE) 6051-0000-222  Pacifitech PT-12A  PPG Biomedical 504055-001, Saracap  Puritan Bennett 4-072214-00  Puritan Bennett NP840 Ventilator 4-074925-00  Sensidyne SV-12A  Sensor Tech (BPR Medical) ST-12,ST-04  Siemens 9004979  Siemens Servo 900, Servo 900C, Servo 900D, Servo 700, Servo 710, Vent. 300, V710 300  Taema YR 049700, Cesar 2, Horus  Teledyne R24MED, B62321  Vascular Technology 103100  Ventrex V-12A  Viasys, CAREFUSION AVEA  VTI 103100  ??200 Zisline Made in Germany
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model GO-04
Country/Region of Manufacture Germany

Directions

Similar products from Nebulizers & Ventilators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies