Mega328 Transistor Tester Diode Triode Inductor Capacitance Esr Meter Lcr Led

US $16.29

  • ShenZhen, China
  • Jun 9th
Top sellers Payment Shipping Warranty Policies Contact Us Categories Mega328 Transistor Tester Diode Triode Inductor Capacitance ESR Meter LCR LED   Description 1. Using ATmega8, ATmega168 or ATmega328 microcontroller. 2. 2x16-character LCD display the results. 3. One button operation, auto power off. 4. Shutdown current is only 20nA, support for battery operation. 5. Low-cost version without the crystal, auto power off. 1.05k version of the software ATmega168 or ATmega328 in sleep mode when no measurement to reduce power consumption. 6. Automatic detection PNP and NPN type bipolar transistors, N, P-channel MOSFET, JFET, diode, a double diode, thyristor SCR. 7. Automatic detection pin layout. 8. Measuring current amplification factor of the bipolar transistor and the threshold voltage emitter junction. 9. Darlington transistor amplification factor can be identified by the high threshold voltage and high current. 10. For bipolar transistor, MOSFET protection diode testing. 11. Measuring the threshold voltage and the gate capacitance of the MOSFET. 12. Supports two resistance measurements and symbols show the highest four numbers and units. Both ends of the resistor symbol is shown connected to the tester probes number (1-3). Therefore, the potential can also be measured. If the potentiometer is adjusted to its end, the tester can not distinguish between the middle and the ends of the pin. 13. Resistance measurement resolution is 0.1 ohms, the highest measured value 50M ohms. 14. Can be detected and measured a capacitor. Maximum four numbers and units. Values can be from 25pf (8MHz clock, 50pF @ 1MHz clock) to 100mF. Resolution up to 1 pF (@ 8MHz clock). 15. Can be larger than the value for 2UF capacitor equivalent series resistance (ESR) measured capacitance value. Resolution of 0.01 ohms and a two-digit numeric display. This feature requires at least 16K Flash ATMEGA (ATmega168 or ATmega328). 16. Two diodes can display symbols in the right direction. In addition, the forward voltage drop displayed. 17. LED detection for diode forward voltage drop is much higher than normal. Dual LEDs detected as double diode. 18. Zener diode can be detected, if the reverse breakdown voltage is less than 4.5V. This will appear as two diodes, can only be determined by the voltage. Probe around the diode symbol is the same, in which case, you can 700mV threshold voltage close to the true recognition diode anode! 19.This year to understand, do not turn the If more than three diode type parts inspection, failure to establish the number of diode display another message. This will only happen if the diode is connected to all three probes and at least one diode. In this case, you should only connect the two probes and start measuring again, one by one. 20. Measurement of a single diode reverse capacitance. Bipolar transistors also can measure, if you connect the base and collector or emitter. Twenty one. Only one measurement to find full-bridge connection. Twenty two. 25pf capacitor value is lower than usual undetectable, but with a diode in parallel or at least 25pf capacitor in parallel. In this case, you have to subtract part shunt capacitance values. Twenty three. Less than 2100 ohm resistors will measure inductance, if you have at least 16K ATMEGA flash. Range from 0: 01mH than 20H, but the accuracy is not good. Measurement results show only a single connection element. Twenty four. Test time is about two seconds, capacitance and inductance measurements will only take a long time. 21. Software can be set to automatically turn off the power measurement times before. 22. Built-in self-test function with selectable clock frequency of 50Hz signal check the accuracy and wait for the call (ATmega168 and ATmega328). 23. Optional internal resistance and zero offset calibration of measuring equipment self-test capability of the port output (ATmega168 and ATmega328). Need a 100nF to 20uF capacitor connected to compensate the analog comparator between pins 1 and 3 of the offset voltage. This can reduce the measurement error 40uF above capacitor. With the same internal calibration capacitor voltage reference voltage is found to internal adjustment reference measurement ADC gain. If the test current exceeds the holding current, the thyristor and triac can be detected. But some current higher than the semiconductor SCR and triac tester can provide the trigger current. Available test current is only about 6mA! Note that all functions have only used single-chip program memory as more ATmega168. Included 1 X Transistor Tester More Products In This Category New Arrivals What's Hot Why Shop At Our Store Payment Shipping Warranty Policies Contact Us We accept PayPal only. All major credit cards are accepted through secure payment processor PayPal. Payment must be received within 7 business days of auction closing. If you have bought multiple items from me, you can send me one payment for all the items instead of paying for them individually. When you click the Pay Now button, eBay will automatically determine if there are other items you have won or purchased from me and will combine them for your review. We Ship to Worldwide, except Italy, Nigeria, and we do not ship to APO/FPO Items will be shipped within 1 business day on payment received. Items are shipped from Hong Kong using Airmail, reach most of the countries within 10 to 20 business days. Delivery time depends on destination and other factors, it may takes up to 20 business days. 12 months Warranty. Buy with confidence! If you are not satisfied when you receive your item, please return it within 14 days for a replacement or money back. Please contact me before you return it. If item is defective in 3 months, We will send you a replacement without extra charger, or offer refund after we receive the defective item. If item is defective after 3 months, you can still send it back to us. We will send you a new one after receiving the defective item. But you have to pay the extra shipping fee. We are not responsible for any custom duty or import tax. We will leave POSITIVE FEEDBACK after receiving the payment. Please contact us if you are not satisfied with the item after receive it. All messages will be answered within 1 business day. If you do not receive our reply, please kindly re-sent your message and we will reply to you as soon as possible. Serious Buyer Only! Please place bid only if you agree with all the terms. On Aug-31-15 at 02:36:02 PDT, seller added the following information:
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Unbranded
MPN Does Not Apply

Directions

Similar products from Inductance, Capacitance, Resistance and Impendace Meters & Analyzers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies