Megger Multi-amp Transformer Ohmmeter, Tap Changer Tester Cat 830280 Calibrated

US $3,779.00

  • Tottenham, Ontario, Canada
  • Jan 29th
 This item is a used Megger Multi-amp Transformer Ohmmeter, Tap Changer Test Set Cat 830280 NIST Calibrated in great condition. Includes leads, manual, hard transit case, and certificate of calibration with data. All pictures are of the actual unit. This item comes with a 3 Month (90 day) warranty.  All functions are guaranteed to work or money will be refunded (buyer pays return shipping only). This item includes a 1 year NIST traceable CERTIFICATE of Calibration with data, dated August 30, 2014.  We Calibrate multimeters, meggers, power supplies, calibrators, and many other products! Contact us for more information on Calibration. The Megger Transformer Ohmmeter is a line-operated, field-portable instrument designed specifically to measure the dc resistance of all types of magnetic windings safely and accurately. Its predominant use is the measurement of the dc resistance of all types of transformer windings within the defined ranges of current and resistance. It can also test rotating machine windings and perform low-current resistance measurements on connections, contacts and control circuits. Three features combine to make this instrument unique: dual measurement, load tap-changer testing and safety shutdown. The dual set of potential inputs measure the resistance of the primary and secondary windings of a single- or three-phase transformer simultaneously. The dual reading characteristic will speed up the measurement when it is used to test windings on delta-delta connected windings on three-phase transformers.  Due to circulating currents induced when the test current is applied to the primary winding, this type of measurement is countered by the same current on the secondary winding. This action attenuates the circulating current and the reading time is improved tenfold. The Transformer Ohmmeter is extremely useful when testing the windings and contact resistance on tap-changers with make-before-break contacts and voltage regulators. The internal shutdown circuit will be triggered by a voltage kickback of a few microseconds if the tap-changer contacts are opened when the tap-changer circuit is operated through all of the tap positions. This action will check for pitted or misaligned contacts as the instrument will shut down if either condition occurs. Users are protected by the shutdown circuit safety feature: any inadvertent disconnection of a test lead or loss of power to the instrument will safely discharge the energy stored in the test sample. The Transformer Ohmmeter's wide resistance range (1 micro-ohm to 1999 ohms) gives the optimum resolution for even the lowest winding resistance tested. -          Direct digital reading saves time, no balancing is required. -          Built-in discharge circuit safely discharges the specimen when test is completed, if lead accidentally disconnects or if power is lost. -          Electromechanical safety indicator gives a visual indication of a charged or discharged specimen, even if power to the instrument is lost. -          Two independent measuring channels allow simultaneous testing of primary and secondary windings or measurement of two phases at a time. -          The sensitive surge detection circuitry monitors the contact operation of on-load tap-changers for the proper make-before-break sequence. If an open circuit condition exists, the instrument shuts down immediately. -          High-accuracy, four-terminal bridge: no lead compensation required. -          Electronically generated and regulated current supply overcomes high-inductance transformers quickly, allowing fast measurements to be taken. -          Display of measurement occurs only after test current stabilizes. -          Wide resistance range is suitable for testing a wide variety of transformers. -          Lightweight and portable, the Transformer Ohmmeter is ideal for use in shop or substation environments. -          Over-temperature protection provides automatic current shutdown and LED indication to prevent instrument damage. -          Instrument and accessories come in a foam-lined transport case. Any questions or clarifications, feel free to ask     Please see our other items! We accept VISA / Mastercard by phone, mail, or email.  Paypal is also accepted. International Buyers – Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying. UPS/FedEx brokerage charges are typically higher than Canada Post/USPS/local post office. Will ship worldwide. We make our best efforts to get you the best shipping prices. Contact us for other international rates and we will be pleased to give you a quote. Sales to within Canada are subject to 5% GST.  Ontario sales subject to 13% HST.
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Great condition, calibrated August 30, 2014. Includes leads, manual, calibration with data, transit case, and 90 day warranty.

Directions

Similar products from Other Electric Power Meters, Analyzers and Supporting Tools

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies