Mks 627a01tac 1 Torr Baratron Pressure Transducer/capacitance Manometer

US $499.99

  • Phoenix, Arizona, United States
  • Jan 30th
Click Here. Double your traffic. Get Vendio Gallery - Now FREE! MKS 627A01TAC 1 Torr Baratron Pressure Transducer/Capacitance Manometer Comes with what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from MKS and may vary slightly due to upgrades, options, or revisions this unit may or may not have. The unit is sold as-is, untested. The MKS Serial Number Tag Reads: Model Number: 627A01TAC Serial Number: 96005281A Range: 1 Torr CE Marked: Yes Link to the Manual: MKS 622A/626A/627A/628A/629A Pressure Transducer Manual Breakdown by Part Number: Type Number: Full Scale Range: 1 Torr Fittings: 1/2 inch (12.7 mm) tubulation Accuracy: ±0.12% of Reading Description: The MKS Baratron Type 622A, 626A, 627A, 628A, and 629A Absolute Pressure Transducers are party of the MKS family of general purpose pressure transducers designed to provide accurate, reliable, and repeatable pressure measurements in teh range from 1K Torr to as low as 0.05 Torr F.S. (627 and 629). These instruments operate with ±15 VDC (±5%) input @ 35 mA, 250 mA, or 500 mA, depending upon the unit, and provide 0 to 10 VDC output linear with pressure. All instruments expose only Inconel to the process permitting use with corrosive or dirty gases and eliminating contamination of the process with transducer materials. Measurements are independent of gas composition and all of the units have a minimum measuring range of four decades. Using the latest single-sided, dual-electrode Inconel transducer design, coupled with a low impedance, fixed-frequency bridge signal condition, these instruments are capable of withstanding high overpressure conditions (45 psia) with minimal or no shifts in output over their range. The advanced bridge signal conditioning technology provides high accuracy and operation which is extremely temperature-stable at operating pressure. Protection from RF interference and noisy electrical environments is increased by the use of the metal case, by intenral design elements, and by the use of surge and ESD suppression networks and RFI filtering on all inputs and outputs. The Types 627, 628, and 629 instruments are designed specifically to meet the needs of vacuum process systems where environmental and process conditions are particularly demanding. Temperature control of the transducer minimizes the effects of ambient or procfess temperature variations typically encountered in process line environments. The 627 and 629 transducers control the transducer temperature a 45°C, thereby minimizing contamination of the process. The Type 627 and 629 transducers have an accuracy of 0.12% of reading (0.1 and 0.05 Torr units have an accuracy of 0.15% of reading). Specifications: Accuracy (Non-linearity, Hysteresis and Non-Repeatability): 0.12% of Reading Ambient Operating Temperature Range5: 15°C to 40°C (59°F to 104°F) CE Compliance - Electromagnetic Compatibility: EMC Directive 89/336/EEC Connector: 15-pin Type "D" Fittings: 1/2 inch (12.7 mm) tubulation Full Scale Range: 1 Torr Input Required: ±15 VDC (±5%) @ 250 mA (max) Materials Exposed to Gases: Inconel Output: 0 to +10 VDC into > or = to 10K ohm load Overpressure Limit without Damage: 45 psia (310 kPa) Temperature Coefficients:   Zero: 0.002% F.S./°C7   Span: 0.02% Reading/°C Time Constant: < 20 msec Usable Measurement Range: 1 x 10-4 F.S. Volume (Px side): 6.3 cc Notes:   5: Do not operate the Type 627 and 629 transducers outside the temperature range.   7: For Type 627 and 629 0.1 Torr transducers, the zero temp. coef. is 0.005% F.S./°C For More Pictures Please Click the Following: Picture 2 - Side View Picture 3 - Top View Picture 4 - Bottom View Picture 5 - Serial Number Tag For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $15.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination. If you have any questions please call Michael at 1-866-MHZ-ELEC (1-866-649-3532) Toll Free. Also, please click here to view or other auctions! 08/27/14 Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
Condition For parts or not working :
An item that does not function as intended and is not fully operational. This includes items that are defective in ways that render them difficult to use, items that require service or repair, or items missing essential components. See the seller’s listing for full details.
Seller Notes The unit is sold as-is, untested.

Directions

Similar products from Other Semiconductors & Printed Circuit Boards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies