Ms200 Nibp Simulator Hr Blood Pressure Simulation, Accuracy Tester Monitor Usa

US $1000

  • Elk Grove Village, Illinois, United States
  • Aug 25th
Introduction  It is a multi - purpose test device for testing NIBP Monitor adopted Oscillometry. Concise and elegant in appearance, easy and convenient to operate, and it can generate the pressure up to 400mmHg (53.3 kPa) by the built-in air pump. With the functions of dynamic BP simulation under several conditions, static pressure calibration, automatic leak test and over-pressure relief test, which can quickly and accurately analyze each performance of NIBP Monitor. Functions 1)Pressure leak test 2)Over-pressure relief test  3)BP simulation under standard condition 4)BP simulation under patient condition 5)BP simulation under arrhythmia condition 6)BP simulation under respiratory interference condition 7)BP simulation of neonate  8)Wrist BP simulation  9)User-defined BP simulation 10)System setting function. 11)The parameters set can be stored. 12)ON/OFF function  13)Dynamic BP simulation Performance BP simulation range:  Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg) Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg) Pulse volume: 0.1 cc ~ 2.4 cc   HR range: 30 bpm ~ 250 bpm; pulse volume > 2.00 cc, maximum HR: 200 bpm HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance)   Under patient condition: Weak pulse, tachycardia, obese, geriatric:   ±preset value 1%+1bpm Moderate exercise:                     ±preset value 1.5%+1bpm Strenuous exercise:                    ±preset value 3%+1bpm Pressure measurement: Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Accuracy:  0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg 40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading Pressure leak test Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds.  Over-pressure relief test Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure. Pressure source: Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc Airtightness Total airtigtness: < 0.3 kPa/min (2.25 mmHg/min) under “OFF” state Airtightness of built-in cuff: 0.27 kPa/min (2 mmHg/min) BP simulation preset value configuration table BP simulation    BP preset value    BP    HR    Pulse volume Standard BP simulation    #1    120/8093    80bpm    0.68cc     #2    150/100116        0.65cc     #3    200/150166        0.60cc     #4    255/195215        0.55cc     #5    60/30(40)        0.75cc     #6    80/5060        0.71cc     #7    100/6576        0.69cc BP simulation under patient condition     Healthy heart    120/80(93)    75bpm    0.68cc     Weak Pulse    110/80(90)    95bpm    0.50cc     Mild Exercise    140/90(106)    120bpm    1.00cc     Strenuous Exer    140/90(106)    162bpm    1.40cc     Obese    120/80(93)    90bpm    0.50cc     Geriatric    150/110(123)    95bpm    0.40cc     Tachycardia    120/105(110)    130bpm    0.40cc     Bradycardia    120/60(80)    45bpm    1.10cc BP simulation under arrhythmia condition     Premature Atrial Contraction1    138/53(81)    80bpm    0.70cc     Premature Atrial Contraction2    144/64(90)    83bpm          Premature Ventricular Contraction    118/61(80)    83bpm         Atrial Fibrillation and PVC    139/72(94)    91bpm     BP simulation under respiratory interference condition     spontaneous breathing1    138/65(89)    104bpm    0.60cc     spontaneous breathing2    149/65(93)    105bpm         spontaneous breathing3    112/47(68)    86bpm         controlled breathing    132/44(73)    98bpm     BP simulation of neonate     #1    35/15(22)    120bpm    0.11cc     #2    60/30(40)        0.10cc     #3    80/50(60)             #4    100/70(80)         BP simulation of wrist cuff     #1    120/80(93)    80bpm    0.50cc     #2    160/100(120)             #3    80/55(63)         User-defined BP simulation[1]    -    -    -    - Note[1]Support 9 user-defined BP simulation modes. The following parameters can be defined by users:2.3.1.The value of diastolic pressure should be lower than systolic pressure, pulse volume and HR can not be set to the highest values (e.g., pulse volume 2.00cc, HR: 250 bpm; pulse volume > 2.00cc, HR: 200bpm). Accessories One User Manual  Two fuses One power cord Physical characteristic Display: 4.3" 65 K color LCD display Power supply: AC100 ~ 240 V   50/60 Hz, <60 VA Environment temperature: + 5 ~ + 40 Relative humidity: < 90 %, non-condnsing Altitude: 3000 m Atmospheric pressure: 80 kPa ~ 106 kPa Dimension: 270 (L) 265 (W) 132 (H) mm Weight: about 4 kg Buy safe Product The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be  subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA  regulation, we will verify your status as an authorized purchaser of  this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of  Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of  United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that  is FDA 510K Approved Please use under the doctor's instruction Shipping: 1). We will ship within 1 business day after your payement ;ship from China warehouse by China Post 2-4 weeks Arrival 2).We don't add taxes, VAT or other hidden charges. You pay us what you see  on the invoice, i.e. goods subtotal + shipping cost (not include  duties). Please find out as much as you can about your import taxes in  your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods, or you may kindly give  us some suggestions about that, we promise to do our best to help you! About Warranty: We guarantee new equipment other than accessories to be free from defects  in workmanship and materials for a period of twelve months (six months  for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing,  at our company's option, any part which upon our company's examination  proves defective. Return Policy: If you receive a defective item which you want to return, please contact  us within 5 days from the day you receive the item. All return items  must be returned with its original packaging and accessories. If we  confirm the damage happened during the shipment, we will bear the  shipping cost for return. We will refund the money to you when we get the return items. Or replace item for you free of charge. 
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Model MS200
MPN 69450401
Country/Region of Manufacture China
Brand CONTEC
UPC Does not apply

Directions

Similar products from Manikins & Dummies for Training

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies