Msa Ultralite Ii Self-contained Breathing Apparatus

US $1,538.33

  • Phoenix, Arizona, United States
  • Jan 30th
MSA Ultralite II Self-Contained Breathing Apparatus All items are sold as is without warranty unless specifically stated in the posting. This does not mean that the unit doesn’t work, only that we have not tested or checked it out. This may also mean that we are not knowledgeable in that specific item. Please call Brent Toll Free at 1-866-MHZ-ELEC (1-866-649-3532) if you have questions between the hours of 9:00 AM and 4:00 PM Monday thru Friday Pacific Time. The Item may vary from picture as manufacture may change model appearance. All information, including description, specifications and features are from a manufacturers data sheet or manual and are subject to change without notice. Meaning that all information included in the description, specifications and features may not be included with the actual item being put up for auction. What you see is what you get! If it doesn’t show it you probably won’t get it! What you are bidding on is a nice looking MSA Ultralite II Self-Contained Breathing Apparatus in nice physical and cosmetic condition. MSA Ultralite II Self-Contained Breathing Apparatus DOT Number: E9634-2216 Part Number: 801376 S/O Number: 100180571 Date: 3-18-00 Cyl: S/NOV- Quantity Available Retail Price: $4,615.00 Features and Benefits: Operation & Instructions Manual Included The self-contained breathing apparatus consists of the following sub-assemblies: Pressure Demand Regulator Air Cylinder and Valve Face piece and Breathing Tube Audi-larm Audible Alarm Carrier and Harness Redundant Alarm/Pressure Gauge For use in atmospheres immediately dangerous to life or health (IDLH) Cylinder Info: 30-min @ 2216 PSIG General Description: The BMR Low Pressure Air Mask is a pressure-demand, self-contained breathing apparatus (SCBA). The regulator is a two-stage device. A balanced first stage provides a uniform pressure to the second stage admission valve. The second stage provides air at a breathable flow rate to the user. The regulator has two distinctly-shaped, hand-operated valves. The gold, knurled knob operates the main-line valve. This valve lets air flow from the regulator to the face piece. The valve is quick-acting, requiring only 1/4 turn to obtain full air flow. Once opened, the valve remains open until the release button is pressed and the knob is turned clockwise. The red, hex-head knob operates the by-pass valve. The valve knob’s distinctive red color and hex shape permit quick identification. The by-pass valve is used only if the main-line valve fails or the regulator fails while the apparatus is in use. The air cylinder and valve consist of a tank and a cylinder valve assembly. The cylinder valve includes a valve body, cylinder valve inlet tube, hand wheels, safety disc (burst disc), and pressure gauge. The pressure gauge shows the air pressure in the cylinder continuously. The gauge is calibrated in 100 PSIG increments. For example, a gauge reading of 20 is read as 20 x 100 or 2,000 PSIG. A hand wheel is used to open and close the cylinder. The face piece lens is super-hard coated to meet the requirements of NFPA 198. This process gives the clear polycarbonate lens superior abrasion and chemical protection. The face piece has a low-resistance , pressure-demand exhalation valve designed for easy cleaning. An inhalation check valve in the inlet housing keeps moisture out of the diaphragm for clear, short range communication. The face piece includes a standard five-point adjustment rubber head harness made of flame and heat resistant (FHR) materials, and features a five-point suspension. Five “points” use self-adjusting, elasticized straps. The breathing tube carries air from the regulator to the face piece. The regulator end of the tube has a metal coupling nut and an insert to guide the coupling nut into the regulator outlet. The face piece end of the breathing tube has a threaded insert to match the face piece coupling nut. The Audi-Larm audible alarm rings when there is approximately 25% of the SCBA’s rated service time remaining. The alarm also rings when the cylinder valve is first opened, providing an audible indication that the alarm is properly “cocked”. The high-pressure hose delivers air at cylinder pressure from the alarm to the first stage regulator. The carrier and harness consists of a back plate, a cylinder band and a latch to hold the cylinder, and a harness, consisting of shoulder pads, a chest strap, adjustable pull-straps, and a waist-strap. The Redundant Alarm/Pressure Gauge is a multi-mode batter-powered, low-pressure warning device which gives audible and visible warning that air cylinder pressure has reached a pre-set level (530 PSIG). There are three warning indicators: 1.) Yellow and red LED’s wigwag on the pressure gauge face, 2.) The pressure gauge face illuminates, and 3.) The audible alarm repeats single tone bursts. Have a nice day and thanks for looking. Enjoy bidding and good luck. This unit is being sold as is. Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.

Directions

Similar products from Mining & Outdoor Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies