New Fluke 17b 3 3/4 Multimeter Ac/dc/diode/r/f/temp/cap

US $119.99

  • United States
  • Jan 30th
      FLUKE 17B Digital MultiMeter   Maximum Voltage between any Terminal and Earth Ground: 1000 V W Fuse Protection for mA µA inputs: 500 mA, 1000 V FAST, Min. Interrupt Rating 20,000 A W Fuse Protection for A input: 10 A, 1000 V FAST, Min. Interrupt Rating 20,000 A Display: Digital: 4000 count updates 3/sec Temperature: Operating: 0 °C to 40 °C, Storage: -30 °C to 60 °C indefinitely (to -40 °C for 100 hours) Operating Altitude: 0 to 2000 meters Temperature Coefficient: 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C) Electromagnetic Compatibility: Complies with FCC Part 15, Class B, IEC 61326, 3 V/m, performance criterion B Rated Transient Overvoltage: 4 kV (1.2 x 50 µs) Peak for measurement Categories I, II, and III. Relative Humidity: Noncondensing < 10 °C 90% from 10 °C to 30 °C; 75% from 30 °C to 40 °C Relative Humidity, 40 M? Range: 80% from 10 °C to 30 °C; 70% from 30 °C to 40 °C Battery Type: 2 X AA, NEDA 15A, IEC LR6 Battery Life: Alkaline: 500 Hours Size (H x W x L): 180 mm x 89 mm x 51.5 mm (with holster) Weight: 425 grams Certifications: CMC, P Safety Compliance: IEC 61010-1, 2000 CAT I 1000 V, CAT II 600 V, and CAT III 300 V overvoltage standards Overvoltage installation categories per IEC 61010-1, 2000: The Meter is designed to protect against transients in these catagories: CAT I: From high-voltage low-energy sources, e.g., electronic circuits or a copy machine. CAT II: From equipment supplied from the fixed installation, e.g., Televisions, PCs, portable tools and household appliances. CAT III: From equipment in fixed equipment installations, e.g., installation panels, feeders and short branch circuits, and lighting systems in large buildings.   Digital Multimeter Accuracy Specifications Accuracy Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])   Function Range Resolution Accuracy Model 15B Model 17B AC Volts (40 to 500 Hz) v 400.0 mV 1 0.1 mV 3.0 % + 3 3.0 % + 3 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 1.0 % + 3 DC Millivolts M 400.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10 DC Volts V 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 0.5 % + 3 0.5 % + 3 Diode Test 1.000 V 0.001 V 10 % Temperature 3 °C (K-type thermocouple) 50 °C to 400 °C 0 °C to 50 °C -55 °C to 0 °C 0.1 °C NA 2 % + 1 °C ± 2 °C 9 % + 2 °C Resistance (Ohms) 400.0 ?4.000 k?40.00 k?400.0 k?4.000 M?40.00 M? 0.1 ?0.001 k?0.01 k?0.1 k?0.001 M?0.01 M? 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 Capacitance 4 c 50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 Frequency Hz (10 Hz – 100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA 0.1 % + 3 Duty Cycle 0.1 % to 99.9 % 0.1% NA 1% typical 5 1. Manual Range only 2. Diode test open circuit test voltage is 1.1 V to 1.6 V and short circuit current is < 0.6 mA (typical). 3. Temperature specifications do not include thermocouple errors. After inserting the thermocouple plug into the meter, allow several minutes for thermal stabilization. 4. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). For the 17B, errors can be reduced by using the relative feature. 5. For values between 10% and 90% duty cycle at 50 Hz. Function Range Resolution Accuracy Model 15B Model 17B AC Current (40 to 200 Hz) 400.0 µA 0.1 µA 1.5 % + 3 1.5 % + 3   4000 µA 1 µA     AC Current (40 to 200 Hz) 40.00 mA 0.01 mA 1.5 % + 3 1.5 % + 3   400.0 mA 0.1 mA     AC Current (40 to 200 Hz) 4.000 A6 10.00 A 0.01 A 0.01 A 1.5 % + 3 1.5 % + 3 DC Current 400.0 µA 0.1 µA 1.5 % + 3 1.5 % + 3   4000 µA 1 µA     DC Current 40.00 mA 0.01 mA 1.5 % + 3 1.5 % + 3 400.0 mA 0.1 mA DC Current 4.000 A6 0.01 A 1.5 % + 3 1.5 % + 3   10.00 A 0.01 A     6. When in the 4A range, display will show 4000 counts, please ignore the last digit.   Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection AC Volts v 1000 V >10 M? <100 pF >60 dB at dc, 50 or 60 Hz _ DC Volts V 1000 V >10 M? <100 pF >100 dB at dc, 50 or 60 Hz >45 dB at 50 or 60 Hz 106 V Hz Max         Thw whole package includes: 1) New FLUKE 17B Multimeter, 2) Thermocouple; 3) A pair of test leads; 4) English manual; To take a look at the detail English Manual: http://assets.fluke.com.cn/evtmanuals/15b17b__cmeng0000.pdf Customer Support Phone Number: (408) 329-7985 Customer Support Skype: Aidetech Our ebay store Policy:  (Please read carefully before you purchase from us, thanks) About items in our listings: All pictures are took by ourselves or from manufacturer, they are real and true. All Mulmeters includes battery and test leads, if you need other optional accessories which list in our action, please buy at our ebay store first and we can add this in your invoice. If you have any questions regarding this, feel free to contact us at sales@ickits.com;  All of our products are sourced directly from manufacturer or our own OEM products, they are brand new with warranty, our price are already big discounted price , normally we couldn't take any offers, but we do have discount for large volume buyer, please contact us for detail. About Shipping: 1) Normally your order will be shipped within 1-3 business days after the payment is clear,  you will receive an e-mail that confirm your order has been shipped within 1-3 days after we receive the payment. Most items are in stock, sometimes some items may be temporary out of stock, if the lead time is more than 7 days, we will e-mail you and let you decide if you want to wait or cancel the order. 2) For domestic USA, the delivery time is 3-5 days by USPS first class/priority mail or 5-10 days by first-class international to Canada, the track number is available upon request, Fast shipping is always available by paying USPS/UPS/Fedex express shipping cost. 3) All International order (outside USA) under 2kg: Most orders will be shipped from our HongKong warehouse by post office air mail, the delivery time: Canada, UK, France: 7-10 days, other North Europe countries: 10-14 days or longer, For Italy, Spain and Brazil may takes longer due to more time is needed for Customs Clearance.  Sorry we are not responsible for any custom duty or broker fee, if needed, we can declare your item as 'gift' or 'sample' for you.  There is NO track number for this method, According to our experience, 0.1%  packages will got lost by using this method. You are very welcomed to pay additional $3.00 for registered mail Or you can paying more for express shipping 5-10 days with track number, the packages may get delayed at your country's customs for several days. If you haven't got your order within 28 business days after your payment is cleared, please DO e-mail us your paypal date and your item # and your shipping address, we will get your back in 1-2 business days. 4) International shipment over 2kg: It will ship by EMS express 5-10 days with track number, the track number will e-mail to you,  additional shipping charge may need for some countries, such as: Brazil, South Africa, Argentina, Chile, Colombia, Costa Rica, Cuba, Turkey, Poland,  Romania, Russia, Slovakia, Ukraine, India, Pakistan and so on,  you can check the detail shipping cost price listing at: (the amount is in USD): http://www.aidetek.com/New_products_info/General/Shipping_price_list_8_31_08.htm 5) Multiple item shipping is OK. Discount shipping prices are given for shipping multiple items in one package to one address: regular price for the 1st item and 30% off shipping for additional items. This discount can only be applied to the item that has lower shipping cost compared with the shipping cost of the 1st item. 6) Check your package before signing on the delievery confirmation, if there is any damage, please refuse to accept it and contact us. Return/exchange policy:  If you are not satisfied with your order, you can return/exchange in 14 days with full money refund (except shipping) as long as the products are in the original shape. please DO contact us before you ship your order back, we will issue a RMA number and return address, the RMA number should appear on the package in order to get refund or exchange.  Customer support/Feedback: Your satisfaction is our highest priority, in case if you are not satisfied with your order or didn't get your order within reasonable time, please do contact us, we will try our best to help you in 1-2 business days.  If you are satisfied with your order, please be kind to leave positive feedback for us, your valued suggestion is highly appreciated, we will send coupon or free gift upon your next purchase for any good suggestions we will take. If you have any questions and concerns, please feel free to e-mail to: sales@ickits.com or by phone (408) 329-7985 or Fax (866) 571-5680. Thanks for interesting in our products and good luck.   Buy our other best products to get 30% discount on shipping, click the image to buy it now: 123 45 678910 Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.

Directions

Similar products from Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies