New Honeywell Notifier Ldm-32 Lamp Driver Module Fire Annunciator Control 417501

US $380

  • Belcamp, Maryland, United States
  • Jun 9th
New, first quality, Honeywell Notifier LDM-32 417501 lamp driver module control circuit board for annunciator control systems. These came from unused and liquidated stock of an electrical company. This box was factory sealed - I opened for photos and to ensure no damage to product from storage or transport.  Inner static bag is SEALED. 1 Available Check out my other listings for tons more fire alarms, detectors, and fire & life safety components I'll be listing.  Best offer for bulk purchases!   Will combine shipping automatically where possible.  Will ship outside the US by ebay's global shipping program where applicable.  I guarantee all components to match descriptions! Manufacturer information from specification sheet: General  The LDM Series lamp driver modules, when combined with a custom graphic display, provide annunciation and control for Notifier’s intelligent fire alarm control panels. These modules use a serial communications interface, and may be located up to 6,000 feet from the panel.  Features  • ALARM/CIRCUIT ON and TROUBLE lamp/LED per-point option, or more dense alarm-only option (field selectable).  • Control switch option for remote control per point.  • Lamps/LEDs may be programmed to display status of indicating circuits or control relays as well as system status conditions.  • System trouble lamp/LED signal.  • On-line/power LED indicator.  • Alarm and trouble resound with flash of new conditions.  • Local sounder for both alarm/circuit-on and trouble conditions with silence/acknowledge switch connection.  • Serial EIA-485 interface for reduced installation costs.  • May be powered by 24 VDC from the panel or by remote power supplies.  • Efficient switch-power converter reduces power consumption.  • Microprocessor-controlled electronics, fully supervised.  • Plug-in terminal blocks for ease of installation and service.  • Trouble monitor option for remote power supplies.  Construction  Two basic models are available; the LDM-32 control module and the LDM-E32 expander module. Each may be selected to provide 32 alarm indications; or 16 alarm, 16 trouble, and 16 control points.  Applications  The LDM-32/LDM-E32 with a custom graphic array may be used to indicate point status and, in some versions, to control the state of output points. In addition, the LDM-R32 module may be used to provide 32 dry-contact relays for electrical isolation when connecting the system to other equipment. Installation  The LDM-32 and LDM-E32 modules mount on four standoffs inside the custom annunciator graphic box. Alternately, the modules may be installed in a CHS-4L chassis. The module size is approximately 4.4” (11.2cm) x 7.1” (18cm). Communications between the LDM Series annunciators and the host FIre Alarm Control Panel are made through a two-wire EIA-485 multi-drop loop, and a two-wire regulated 24 VDC power loop. Up to 32 LDM systems may be connected to a single control panel. All field-wiring terminations use removable, compression-type terminal blocks for ease of installation, wiring, and circuit testing.  Operation  LDM Series modules, when used with a custom graphic annunciator, provide the Notifier’s intelligent fire alarm control panels with up to 32 unique or redundant annunciators, each with a capacity of 64 points for a total capacity of 2048 points. Local or remote power supplies and serial communications allow the custom annunciators to be located anywhere on the protected premises. AM2020/AFP1010 system alarm and/or trouble conditions may be annunciated on a per-point basis, or in a grouped-zone configuration. AFP300/400 system panel points, intelligent addressable devices and software zones can be annunciated/controlled in a grouped fashion (see programming manual for details). Control of system operational controls, such as Signal Silence, System Reset, and local annunciation controls (such as Local Acknowledge), and Lamp Test may be accomplished through special key- or push-switches.  Agency Listings and Approvals  These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.  • UL Listed: S635  • ULC Listed: S635  • MEA Listed: 291-61-E Vol. 4 (System 500, LDM-R32); 289-91-E Vol. V (AM2020/AFP1010); 104-93-E (AFP-200); 17-96-E (AFP-300/400); 447-99-E (AFC-600)  • CSFM: 7120-0028:0156, 7165-0028:0224 (NFS-3030, NFS2-3030); 7170-0028:0223 (NFS-3030, NFS2-3030)  • BSA: 578-81-SA (System 5000, System 500 except LDM-R32)  • FM Approved  • City of Chicago approved: Class 1, Class 2  • City of Denver approved  • FDNY COA #6085 (NFS2-640); 6065 (NFS2-3030)

Directions

Similar products from Fire Alarming Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies