***new*** Silent Knight Sk2 By Honeywell 2 Zone Fire Panel

US $289.99

  • Virginia, Minnesota, United States
  • Jan 30th
***New In Box*** Silent Knight SK2 Conventional Fire Control Panel by Honeywell Silent Knight SK2 2 zone Fire Alarm Control Panel The SIL-SK2 is a 2 zone Fire Alarm Control Panel that is compatible with devices such as two or four wire smoke detectors pull stations or any other normally open contacts. Upon activation of any compatible smoke detector or any normally-open compatible fire device; the panel can activate strobes, light up an LED to alert you, sound the sounder at the panel, and also activate a communications device to notify a remote monitoring station. This panel is also compatible with the new System Sensor i3 devices which have many features to help keep your system operating smoothly. It also features NAC protocol which means that sounders can be silenced, but the strobes will still function and this all through the use of a single pair of wires. Specifications: SK-2 Primary AC: 120 VAC @ 50/60 Hz, 2.3A SK-2E Primary AC: 240 VAC @ 50 Hz, 1.15A Wiring: 14 AWG (2.0 mm2) with 600 V insulation min Initiating Device Circuits (IDCs) Operating Voltage: 22 VDC nominal; power-limited Standby Current: 4 mA Alarm Current: 15 mA min Short-circuit Current: 40 mA max Loop Resistance: 100z max EOL Resistor: 4.7K z, 1/2 watt NACs 2.5A @ 24 VDC with standard transformer, power-limited Signaling Current: 2.5A max with standard transformer EOL Resistor: 4.7K z, 1/2 watt Form C Relays Types: Trouble and alarm Contact Ratings: 2A @ 30 VAC, resistive Auxiliary Output Resettable Operating Voltage: 24 VDC nominal Current: 500 mA max, power-limited Features • Two Style B (Class B) initiating device circuits (IDCs) • One Style Y (Class B) notification appliance circuit (NAC) • Support for synchronization of standard ANSI audible signals and ADA compliant strobes per NFPA 72 • Selectable for System Sensor, Wheelock, and Gentex protocols • Selective silence feature allows manual silence of horns while strobes continue to flash on the same NAC • Silent or audible walk test operation mode • Alarm verification selectable per zone • Program each zone for supervisory or fire with separate red and yellow LEDs • Disable switches provided per zone • Program NACS for – Silence inhibit – Auto silence – Strobe synchronization – Temporal or steady signal – Silenceable or nonsilenceable – Disable • Form C alarm and trouble relays • 3A total usable current • Optional dress panel (PN SK-DP2/4)
Condition New other (see details) :
A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections.
Seller Notes Only opened for pictures and to power it up.

Directions

Similar products from Control Boards & Panels

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies