Omegaphh-103 Thermometer Meter

US $125.00

  • Memphis, Tennessee, United States
  • Jan 29th
PHH-103 pH/mV/TEMPERATURE METER INSTRUCTION SHEET M4318-0606 Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info pH/mV/Temperature Meter  The PHH-103 is a Microprocessor based designed. The rugged housing and splash proof keyboard make the PHH-103 ideal for measurements outside of the laboratory. The large LCD displays pH and temperature values simultaneously, or can show millivolts. The PHH-103 has five memorized buffer values for fast, convenient and accurate calibration. User can perform a one-point calibration at any of these values, or a two-point calibration using any of the remaining buffer values, or adjust buffer values as needed under calibration mode and flash status by UP and DOWN key. the LCD display will indicate percentage of slope (PTS) to show the status of electrode after slope calibration. The PHH-103 has low battery consumption indicator and will auto shut off after 10 minutes of non use. Specifications: Range: 0.00 to 14.00 pH, +1999 mV, 0 to 100°C Accuracy: 0.02 pH, 2 mV, 0.3°C Resolution: 0.01 pH, 1 mV, 0.1°C ATC: 0 to 100°C Calibration: pH1.68, 4.00, 7.00, 10.00, 12.45 Battery: 9V Dimensions: 108 x 75 x 30 mm Weight: 135 g (with battery) Accessories: Upon receiving the shipment, inspect the container and equipment for any signs of damage. Remove the packing list and verify that you have received all equipment: Meter, pH electrode, temperature probe, Buffer solution 4.00 & 7.00, Battery 9V, Operating manual and rubber protective holster  Operating Procedure: Preparation: 1. Open the battery compartment and connect the 9V battery. 2. Remove the protection cap from the electrode and connect to BNC input. 3. Turn on the power switch. 4. Rinse the electrode with clean water and wipe it dry. Calibration: 1. Dip and stir the electrode into the buffer solution pH 7.00. Press and hold CAL key 3 second to into calibration mode. The display will appear CAL and flash 7.00. When the display stop flashing then it’s end of calibration 2. Dip and stir the electrode into the buffer solution pH 4.00 and same as step 1. Note: Calibration value can be adjusted as your buffer solution value under CAL mode and flash status by UP and DOWN key. For example, pH 6.86 instead of pH 7.00 3. After slope calibration, the LCD display will indicate percentage of slope (PTS) to show the status of electrode. Measurement: 1. After calibration, rinse the electrode with clean water and wipe it dry. Dip the electrode into sample solution to be measured. Stir gently and wait until a stable reading can be obtained. 2. Press pH/mV key to change pH or ORP mode as needed. Others: 1. Degree C and F can be changed by press and hold pH/mV key 3 second. 2. Automatic temperature compensation(ATC) mode by insert temperature probe. Manual temperature compensation mode by up and down key. 3. Auto shut off after 10 minutes of non use. 4. Change a new battery when the battery indicator flashing. Applications: Floriculture, Fish farming, Agriculture, Swimming pool FREE! Sellers: Add a FREE map to your listings. FREE!
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Very lightly used...

Directions

Similar products from Gas & Water Flow Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies