Omron Timer H3de-m2 Ac/dc24-230

US $40.00

  • Fairmount, Illinois, United States
  • Jun 9th
THESE TIMERS WERE TAKEN OFF A MACHINE NO LONGER IN SERVICE AND ARE KNOWN TO BE IN GOOD WORKING CONDITION.THIS AUCTION IS FOR A LOT OF 2.Timer, Multifunction Type, DPDT, Analog, 0.1 Second to 120 Hours, 24-230 VAC/VDCMfr. Part#: H3DE-M2 AC/DC24-230 Analog Timer, DC24 to 240V, AC24 to 240V Rated supply voltage 24 to 240VAC 50/60 Hz 24 to 240VDC ripple: 20% max. Input signals Start Input method Voltage input Control output (Type) Relay output (DPDT) Rated supply voltage 24 to 240VAC 50/60 Hz 24 to 240VDC ripple: 20% max. Operating voltage range 85% to 110% of rated supply voltage Input signals Start Input method Voltage input Voltage input High (logic) level: 20.4 to 264 VAC/DC Low (logic) level: 0 to 2.4 VAC/DC Minimum input signal width 50 ms min. (Start input) Power consumption ( Relay ON ) 6.6VA(at 240 VAC) 1.2W(at 24 VDC) Power consumption ( Relay OFF ) (at 240 VAC) (at 24 VDC) Reset voltage 10% max. of rated supply voltage Number of time ranges 8 Time ranges 0.1s~1.2s / 1s~12s / 10s~120s / 1min~12min / 10min~120min / 1h~12h / 10h~120h / 100h~1200h Operating mode ON delay, Flicker OFF start, Flicker ON start, Signal ON/OFF delay, Signal OFF delay, Interval, Signal ON/OFF delay, One shot output Control output (Type) Relay output (DPDT) Control output (Contact output) Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 30VDC 5A Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.15A Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.1A Minimum applicable load: 10 mA at 5 VDC (failure level: P) Ambient temperature Operating: -20 to 55°C Storage: -40 to 70°C Ambient humidity ???: 25~85% Accuracy of operating time +/- 1% max.(FS) (+/- 1% +/- 10 ms max. in a range of 1.2 s) Setting error -10 to 10% +/- 0.05 s max. (FS) Influence of voltage +/- 0.5% FS max. (+/- 0.5% +/- 10 ms max. in a range of 1.2 s) Influence of temperature +/- 2% FS max. (+/- 2% +/- 10 ms max. in a range of 1.2 s) Insulation resistance 100 M? (at 500 VDC) Dielectric strength between current carrying metal parts and non-current carrying metal parts: 2000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit: 2000 VAC, 50/60 Hz for 1 min between non-continuous contacts: 1000 VAC, 50/60 Hz for 1 min Impulse withstand voltage between power terminals: 5 kV between exposed non-current-carrying metal parts: 5 kV Noise immunity +/- 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 us, 1-ns rise) Static immunity Mulfunction: 4 kV Destruction: 8 kV Vibration resistance (Destruction) 10 to 55 Hz, 0.75 mm single amplitude each in X, Y, and Z directions for 2 hours Vibration resistance (Malfunction) 10 to 55 Hz, 0.5 mm single amplitude each in X, Y, and Z directions for 10 min Shock resistance (Destruction) 1000 m/s**2, 3 times each 6 directions Shock resistance (Malfunction) 100 m/s**2, 3 times each 6 directions Mechanical life expectancy (relayoutput) 10000000 operations min. (under no load at 1800 operations/h) Electrical life expectancy (relay output) 100000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) Degree of protection IP30(Terminal Block: IP20) Weight (Main) Approx. 120 g
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand OMRON
Model H3DE-M2 AC/DC24-230

Directions

Similar products from Timers, Time Switches & Timer Relays

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies