Pair Of Fluke Calibration, Hart Scientific 5615-6-p Secondary Temperature Probe

US $749.99

  • Miami, Florida, United States
  • Feb 12th
lighty used pair of fluke hart scientific 5615-6-p secondary reference temperature standard probes. lemo connector for fluke 1523-1524 reference thermometer and others. Durable, accurate sensors for use in the factory, field or lab Affordable wide-range accuracy Calibrated accuracy ± 0.012 °C at 0 °C Reference-grade platinum sensing element NVLAP-accredited calibration included, lab code 200706-0 Specifications Temperature range   5615-6: –200 °C to 300 °C Nominal resistance at 0 °C 100 ? ± 0.10 ? Temperature coefficient 0.0039250 ?/?/°C Accuracy[1]     ± 0.024 °C at –200 °C ± 0.012 °C at 0 °C ± 0.035 °C at 420 °CC Short-term repeatability[2] ± 0.009 °C at 0.010 °C Drift[3] ± 0.007 °C at 0.010 °C Sensor length 28 mm (1.1 in) Sensor location 6.9 mm ± 3.3 mm from tip (0.27 in ± 0.13 in) Sheath dimensions 5615-6: 152 mm x 4.76 mm (6.0 in x 0.188 in) Sheath diameter tolerance ± 0.127 mm (± 0.005 in) Sheath material Inconel™ 600 Minimum insulation resistance 1000 M? at 23 °C Transition junction temperature range[4] –50 °C to 200 °C   Transition junction dimensions 71 mm x 13 mm dia (2.8 in x 0.5 in) Maximum immersion length     5615-6: 102 mm (4 in) Response time[5] 9 seconds typical Self heating (in 0 °C bath) 50 mW/°C Lead-wire cable type PTFE insulated with PTFE jacket, 22 AWG Lead-wire length 183 cm (72 in) Lead-wire temperature range –50 °C to 200 °C The 5615-12 is a Platinum Resistance Thermometer (PRT) with an Inconel™ 600 sheath that’s 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter. It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations. It has accuracy of ± 0.012 °C at 0.01 °C. The element is constructed of reference-grade platinum wire (99.999 % pure) for excellent stability. The wire is wound in a coil and placed in a mandrel where it’s uniformly supported in a manner that virtually eliminates hysteresis. The electrical configuration is a four-wire current-potential hookup that eliminate the effects of lead-wire resistance. These Inconel™-sheathed probes have a fully supported sensing element, making them more durable than SPRTs. The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants. This probe comes calibrated with ITS-90 coefficients, making it compatible with many excellent readout devices, including Fluke Calibration’s 1529 Chub-E4, 1560 Black Stack, and 1502A Tweener. It bridges the gap between a 100-ohm industrial RTD and an SPRT. For those needing faster thermal response, or where diameter and immersion depth are problems, order the 5615-9 or 5615-6. These probes are excellent reference probes for comparison calibrations in a Fluke Calibration dry-well. The sheaths of the 5615-6 and 5615-9 are 4.76 mm (0.188 in) in diameter. A printout of sensor resistance is provided in 1 °C increments for each probe. The 5615-9 and 5615-12 are calibrated from –196 °C to 420 °C. The 5615-6 is calibrated to 300 °C. We’ve tested many of the probes on the market. We’ve used them in our manufacturing facility and tested them in the lab, and this is an excellent secondary standards PRT. Other instruments on the market are priced much higher, have lower stability, or are of lower quality. Remember, these are reliable instruments and each probe comes with its own individual NVLAP-accredited calibration, lab code 200706-0.

Directions

Similar products from Process, Temperature & Pressure Calibrators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies