Part#stv-6501g

US $990.00

  • Hayward, California, United States
  • Jun 21st
Switched POPS PDU - 3.3kW, STV-6501G The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS “Primary” PDU can be connected to as many as three (with optional module) PRO2 Switched POPS “Link” PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration. https://www.servertech.com/power-distribution-unit-pdu/switched-pops-pdu/0u-vertical-2G01/stv-6501g Inputs Input Voltage (V): 208 Input Plug: IEC C20 100-240V Inlet Input Current (A): 20 Input Current Rated (A): 16 Input Power Capacity (kW): 3.3 Requires PTCORD-L1, -L2, -L3, -L4, -L5, -L6, or –L7 Outputs Connector Rating (24) x IEC 60320/C13 North American Rating: 12A @208V L-L (15A Peak) Global Rating: 10A @230V L-N (6) x IEC 60320/C19 North American Rating: 16A @208V L-L (20A Peak) Global Rating: 16A @230V L-N Branch Circuit Protection UL489 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: 16A, 5 kAIC Interrupt Rating Physical Dimensions: 69.0in tall x 2.2in wide x 2.25in deep [1753mm x 56mm x 58mm] Environmental Operating Environment: 32°F to 140°F / 0°C to 60°C | 8%RH to 90%RH non-condensing | 6,500ft/2km elevation Storage Environment: -40°F to 185°F / -40°C to 85°C | 8%RH to 90%RH non-condensing | 50,000ft/15km elevation Quiescent / Unloaded Power Draw: < 10W for all configurations Communications & Security 10/100/1000 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector) Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU} Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP Certifications North American: cTUVus Mark to UL 60950-1:2007 R10.14 CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014 FCC Part 15 Subpart B Sections 15.107 and 15.109, Class A Global: TUV T-Mark to EN 60950-1:2006+A11+A1+A12+A2 EMC to EN55024 (2010) and EN55032 (2012) CE Compliant RoHS, European Hazardous Materials Directive (Recast) 2011/65/EU WEEE Compliant Measurement Accuracy Input Measurement Accuracy: LED Current = ± 10% at 0.1 amp (0.3 - 9.9 amps) and 1 amp (> 9.9 amps) resolution GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp) Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%) Active Power = ± 1% at 1 watt resolution Apparent Power = ± 1% at 1 volt-amp resolution Power Factor = ± 3% at 0.01 resolution Crest Factor = ± 10% at 0.1 resolution Energy = ± 1% at 0.1 kilowatt-hour resolution Output Measurement Accuracy GUI Current = ± 1% at 0.01 amp resolution (above 0.15 amp) Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%) Active Power = ± 1% at 1 watt resolution Apparent Power = ± 1% at 1 volt-amp resolution Power Factor = ± 3% at 0.01 resolution Crest Factor = ± 10% at 0.1 resolution Energy = ± 1% at 1 watt-hour resolution Branch Measurement Accuracy Current = ± 3% at 0.01 amp resolution (above 0.5 amp)
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Mounting Style Flexible Mounting
Brand Server Technology
MPN STV-6501G
UPC Does not apply

Directions

Similar products from Power Regulators & Uninterrupted Power Supplies

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies