Potter Signal Ipa-4000 Fire Alarm Control / Release Panel Brand New, Sealed Box

US $1,205.00

  • McHenry, Illinois, United States
  • Aug 2nd
Potter Signal IPA-4000 Fire Alarm Control Panel This is a NEW Sealed Box item. FEATURES •          4,064addresses available on this analog addressable system •          Additionalsystem capacity achieved via multi-point SLC modules •          1500 softwarezones •          NFPA 72Compliant Smoke Sensitivity Test Built-In •          SystemOperates as Class A or Class B for SLC, P-Link and NACs •          10 Amp PowerSupply, Expandable to 315 amps •          6 NACS,Regulated, Rated at 3 Amps each, expandable to 192 •          4Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, idealfor manual release and abort •          StrobeSynchronization & System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes •          DedicatedAlarm, Supervisory and Trouble Relays •          4,000 EventHistory Buffer •          Cabinet willhouse up to 18 AH batteries •          Optional 2-lineDACT with UD-2000 that can report General, Zone or Point information •          Built in IPcommunicator •          Ethernet Portfor Programming and Network Connectivity •          E-Mail SystemStatus, Reports and Event Information •          Productincludes 5-year warranty •          UUKL Listed for Smoke Control  DESCRIPTION The IPA-4000is an expandable analog/addressable releasing fire alarm system with a totalsystem capacity of 4,064 addresses. Additional capacity on the system isachieved using multi-point SLC modules The control panel utilizes the exclusivePotter protocol that includes a complete line of sensors and modules. Thesystem is expandable with a total of thirty-one additional addressableSignaling Line Circuits (SLC) each with a maximum of 127 devices. Each SLC maybe comprised of any combination of smoke sensor, heat detectors or modules andallows for a total of 50 ohms of impedance and may use any wire compliant withthe National Electrical Code (NEC). The IPA-4000 has a 10 Amp power supply with sixNotification Appliance Circuits (NACs) and four Input/output (I/O) circuits.The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Eachoutput is regulated, and power limited. In addition, each output is uniquelyprogrammable and may be configured for steady signal, strobe synchronization,constant power, door holder power, or releasing. The strobe synchronizationincludes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with theexclusive Quadrasync each output may have aunique brand and all strobes will flash together. The I/Os are designed forinputs such as manual release stations and abort switches that will not requirepolling and react nearly instantaneously. The IPA-4000is listed for releasing of fire suppression systems. The software allows crosszones, counting zones, and timers for suppression. The system is capable ofmultiple release outputs across multiple hazards. In addition, the PSN-1000 maybe used to extend releasing capability. The NACs may be expanded using thePSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Ampsof power, 2 additional input circuits and the IPA-4000 will support up to 31power supplies. The system will synchronize the strobes system wide. Inaddition, the PSN-1000E has space to allow the installation of up to sixPAD100-SLCE SLC loop expansion cards. The cards mount on a stacker bracket thatallows access to all SLC circuit connections.   NO WARRANTY FROM MANUFACTURER  USER INTERFACE The fire alarm control panel has a 4 x 40 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: • AC Power - Green • Alarm - Red • Earth Fault - Amber • Supervisory - Amber • Silenced - Amber • Trouble - Amber • Pre-Release - Amber • Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-LINK The IPA-4000 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PAD100-SLCE-Analog/Addressable loop expansion module (maximum of 31 per IPA-4000) RA-6075R – 2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) – 4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) – 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) – 10 amp, remote intelligent power supply with  6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in conjunction with the IPA-4000 as releasing circuits. CA-6500 – Class A convertor that converts the SLC, NACs and  P-Link connection UD-2000 – UL listed, Dual line telephone alarm communicator DRV-50 – LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 – Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 – Fiber interface module, used to extend P-Link to multi-mode fiber (2 required) RLY-5 – Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 – Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. IDC-6 – Initiating device circuit provides 6 programmable inputs AE-2 – Two card expansion cabinet AE-8 – Eight card expansion cabinet AE-14 – Fourteen card expansion cabinet ETHERNET/ I.P.CONNECTION The IPA-4000 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected  to a building Wide Area Network (WAN) or Local Area Network  (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. INFORMATION Weight 20 lbs. Dimensions 5" 19" 28" Inch Color Red Series Potter IPA Series: Fire Alarm Systems
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Ptter
MPN 3992717
Type Fire Alarms
Country/Region of Manufacture United States
Custom Bundle No
Modified Item No
Model Potter Signal IPA-4000

Directions

Similar products from Fire Alarming Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies