Prova 903 Dual Channels Digital Multimeter New Prova903 Brand New And Original

US $269.72

  • Shenzhen,China, China
  • Jan 29th
                                                                                                                                                                                                                                                                                                                                                                                                                                                                       FEATURES: The DMM to replace your bench-top one       0.02% DC and 0.1% AC basic accuracy       60,000 counts resolution       200KHz (max.) bandwidth       True RMS with fast ACV/ACA response       Dual channels measurement similar to a dual channels DSO (V+V, V+A)       RS-232C ASCII interface       Data logging (model 903 with 10,708 records for both channels)       Capacitance measurement       Free software (901,903)       1/3 the cost                                                                                                                                                                                                                                                                                                                                                                                                               SPECIFICATION:   The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ±% of reading ± number of least significant digits.                                                                               Continuity : ( , open voltage 3V approx.)                                                                                                                                                                                                                                                                     Range Resolution Beeper Overload Protection 999.99 ? 0.01 ? < 40 ? ( approx ) AC 1000V                                                                               Diode Test : (open voltage 3V approx.) Range Resolution ShortCircuit Current Overload Protection 3.0000V 0.0001V 0.8 mA typical AC 1000V                                                                               Frequency : Range ( Auto ) Resolution Accuracy Overload Protection 1Hz - 200KHz( sine wave ) 0.0001Hz -100Hz ±0.02%±4dgts AC 1000V 1Hz -2MHz (TTL) 0.0001Hz - 0.0001MHz ±0.005%±4dgts AC 1000V                                                                               Duty Cycle : (%, TTL, 1Hz – 600KHz ) Range Resolution Accuracy Overload Protection 0.001% - 9.999% 0.001% ±30d/KHz±30dgts AC 1000V 10.00% - 100.00% 0.01% ±3d/KHz±3dgts AC 1000V                                                                               Resistance: ( ? ) Range Resolution Accuracy Overload Protection 999.99 ? 0.01 ? ±0.15%±8dgts AC 1000V 9.9999K ? 0.0001K ? ±0.09%±3dgts AC 1000V 99.999K ? 0.001K ? ±0.09%±3dgts AC 1000V 999.99K ? 0.01K ? ±0.09%±3dgts AC 1000V 9.9999M ? 0.0001M ? ±0.2%±6dgts AC 1000V 40.000M ? 0.001M ? ±1%±6dgts AC 1000V                                                                               Capacitance: ( , auto range , and for film capacitor or better) Range Resolution Accuracy 1 60.00nF 0.01nF ±0.8%±5dgts 600.0nF 0.1n F ±1.5%±5dgts 6.000 ? F 0.001 ? F ±1.5 %±5dgts 60.00 ? F 0.01 ? F ±2.0%±5dgts 600.0 ? F 0.1 ? F ±3.5%±5dgts                                                                               DC Voltage: (Input Impedance: 10M ) Range Resolution Accuracy Overload Protection 60.000mV 0.001mV ±0.1%±5dgts 1 DC 1000V 600.00mV 0.01mV ±0.02%±3dgts DC 1000V 6.0000V 0.0001V ±0.02%±3dgts DC 1000V 60.000V 0.001V ±0.02%±3dgts DC 1000V 600.00V 0.01V ±0.02%±3dgts DC 1000V 1000.0V 0.1V ±0.04%±3dgts DC 1000V                                                                               DC Current: (10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of ? A and mA is protected by 1A fast blown, high energy fuse ) Range Resolution Accuracy 600.00 ? A 0.01 ? A ±0.2%±10dgts 6000.0 ? A 0.1 ? A ±0.1%±10dgts 60.000mA 0.001mA ±0.2%±10dgts 600.00mA 0.01mA ±0.1%±10dgts 1.0000A 0.0001A ±0.1%±10dgts 10.000A 1 0.001A ±0.3%±10dgts                                                                               AC Current: (The accuracy is specified for a single channel for 5%-100% of range for 45Hz – 20KHz, True RMS, 10A terminal is protected by a 10A fast blown, high energy fuse, and the terminal of ? A and mA is protected by 1A fast blown, high energy fuse )                                                                                                                                                                                                                                                                                     Range (ACA) Resolution Accuracy (50/60Hz) Accuracy (45Hz - 1KHz) 600.00 ? A 0.01m A ±0.3%±20dgts ±0.4%±20dgts 6000.0 ? A 0.1m A ±0.3%±20dgts ±0.4%±20dgts 60.000mA 0.001mA ±0.3%±20dgts ±0.4%±20dgts 600.00mA 0.01mA ±0.3%±20dgts ±0.4%±20dgts 1.0000A 0.0001A ±0.3%±20dgts ±0.4%±20dgts 10.000A 1 0.001A ±0.5%±20dgts ±0.4%±20dgts                                                                                                                                                                                                                                                                                     Range (ACA)                                    Accuracy (20Hz - 45Hz)                             Accuracy (1KHz – 10KHz)                                  Accuracy (10KHz – 20KHz)                   600.00 ? A ±1%±20dgts ±2%±20dgts ±1%±20dgts 6000.0 ? A ±1%±20dgts ±2%±20dgts ±1%±20dgts 60.000mA ±1%±20dgts ±0.5%±20dgts ±1%±20dgts 600.00mA ±1%±20dgts ±0.5%±20dgts ±1%±20dgts 1.0000A ±1%±20dgts ±1.5%±20dgts Not Specified 10.000A 1 ±2%±20dgts ±1.5%±20dgts Not Specified                                                                               AC Voltage: The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz – 10KHz, average sensing. Input Impedance is 10M , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the unit.                                                                                                                                                                                                                   Range (ACV) Resolution Accuracy (50/60Hz) Accuracy (45Hz - 1KHz) Accuracy (20Hz - 45Hz) 60.000mV 0.001mV ±0.1%±20dgts ±0.3%±20dgts ±0.8%±25dgts 600.00mV 0.01mV ±0.1%±20dgts ±0.3%±20dgts ±0.8%±25dgts 6.0000V 0.0001V ±0.1%±20dgts ±0.3%±20dgts ±0.8%±25dgts 60.000V 0.001V ±0.1%±20dgts ±0.3%±20dgts ±0.8%±25dgts 600.00V 0.01V ±0.1%±20dgts ±0.5%±20dgts ±0.8%±25dgts    1000.0V (0–400V)                   0.1V ±0.1%±20dgts ±2%±30dgts ±0.8%±25dgts      1000.0V (400-1000V)                0.1V ±0.1%±20dgts       (45Hz – 400Hz) ±2%±30dgts                   ±0.8%±25dgts                                                                                                         Range (ACV)            Accuracy 1KHz–10KHz)                   Accuracy (10KHz–20KHz)                   Accuracy (20KHz-50KHz)                   Accuracy (50KHz-100KHz)                   Accuracy (100kHz-200KHz)                   60.000mV ±2%±20dgts ±2.5%±20dgts ±4%±40dgts ±4%±40dgts Not Specified 600.00mV ±1%±20dgts ±2.5%±20dgts ±2%±40dgts ±2%±40dgts ±2%±40dgts 6.0000V ±1%±20dgts ±2.0%±20dgts ±2%±40dgts ±2%±40dgts ±2%±40dgts 60.000V ±1%±20dgts ±2.0%±20dgts ±4%±40dgts Not Specified Not Specified 600.00V (0-400V)                   ±5%±20dgts Not Specified Not Specified Not Specified Not Specified                 600.00V (400-600V)                   Not Specified Not Specified Not Specified Not Specified Not Specified           1000.0V (0-400V)                   ±2%±40dgts Not Specified Not Specified Not Specified Not Specified              1000.0V (400-1000V)                   Not Specified Not Specified Not Specified Not Specified Not Specified                                                                               Supplemental Dual Channels Specification (DC – 400Hz): The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.                                                                                                                                                                                                                                                                                                                                                                                                                                   ACV (Ch2) DCV (Ch2) ACA (Ch2) DCA (Ch2) ACV (Ch1) ±1%±( V1 - V2 ) 200 PPM (Ch1, Ch2) ±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2) ±0.1 ? A / V( ? A,Ch2) ±1 ? A / V (mA,Ch2) ±0.2mA / V (A, Ch2) ±2mV / A (mV, Ch1) ± 5mV / A (V, Ch1) ±0.25% (Ch1, Ch2) DCV (Ch1) ±0.5%±(V1 - V2) * 20 PPM (Ch1, Ch2) ±0.25% (Ch1,Ch2 ±0.25% (Ch1, Ch2) ±0.25% (Ch1, Ch2)                                                                               General Specification Battery Type 9V Display 5 + 5 digits LCD with 30 segments bar graph Range Selection auto and manual Overload Indication OL Power Consumption 6 mA ( approx ) Low battery Indication Operating Temperature -10 C to 50 C Operating Humidity less than 85% relative Altitude up to 2000M Storage Temperature -20 C to 60 C Storage Humidity less than 75% relative Dimension 207mm(L) x 101mm (W) x 47mm (H)8.15" (L) x 4" (W) x 1.85" (H) Weight 430g / 15.2oz (battery included) Accessories                                                                                                                                                                                                                                                                       Users manual x 1   RS-232C interface cable          Notice: The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your support!           Items are only shipped after PAYMENT is received           Please check out your ADDRESS carefully when processing order           If you haven't received the parcel in 25 days,please allow us 2-3 days for checking undelivered packages before we issue you refund           We can't ship to African countries becasuse of shipping company policy.           To USA UK Austrial  7-15 days by e-package, others 15-45 days.           If you want to send DHL / UPS / TNT/ Fedex please contact me alone to change the price.                  Accepts payment with PayPal. Via paypal you can use all major credit cards. Items do not ship until payment is recieved in full.          If the item is defective, please notify us within 7 days after the receipt of the item.          The item shall be return in its original condition, in order to get it refunded or replaced             We rely on our reputation and customer satisfaction to succeed,Therefore,your feedback is extremely important to us ,please leave good feedback to us if you get satisfied             with our goods and service.             We care about our valued customers,and will always try to help you.             Please give us the opportunity to resolve any problem.We understand the concerns and frustrations you might have,and will try your best to resolve the issues.             Please email us before leaving any negative feedback or opening any dispute on the site.We will help you to resolve the problem                               Attention! eBay Custom Tax Policy                  The policy of customs clearance may differ from each country.                  We are not responsible for any applicable customs charge, taxes and duties.                 Import duties and taxes are buyer's responsibility.                  If you have any inquiry for custom clearance, please leave a message.                  We will mark the price you want to declare after communication.                     On Apr-28-14 at 11:09:09 PDT, seller added the following information:
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand PROVA 903
Country/Region of Manufacture Taiwan
Model 903

Directions

Similar products from Inductance, Capacitance, Resistance and Impendace Meters & Analyzers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies