Puritan Bennett Lp10 Portable Ventilator Patient Respirator Vent And Circuit

US $320.00

  • Dallas, Wisconsin, United States
  • Jan 30th
 PURITAN BENNETT LP10 Portable Ventilator Patient Respirator vent The Puritan-Bennett LP10 is a highly portable, dependable, comprehensive ventilator designed to enable smooth transition from critical care ventilation. The LP10's extensive features and portability provide the flexibility to meet a broad range of ventilation and patient needs. Ventilator comes with one complete used circuit. Ventilator works flawlessly and with no problems. Features: • Designed for smooth transition from critical care ventilation • Meets a broad range of pediatric and adult needs. • Decreased internal resistance reduces breathing efforts in SIMV mode • Reliable ventilator monitoring displays Typical Manufacturer’s Picture Specifications Power Line 110 VAC range (100-127 VAC) or 220 VAC range (220-240 VAC), 50/60 Hz, external voltage selector switch Power Usage Maximum 630 kW hours per year Nominal 315 kW hours per year External Battery Approximately 20 hours operation with 75-80 ampere-hour 12 VDC deep-cycle, gel-cell battery; approximately 10 hours with 35-40 ampere-hour 12 VDC deep-cycle, gel-cell battery Internal Battery Up to 1 hour operation Type, Volume Ventilator Motor: Brushless induction Pump Piston, 100-2200 mL tidal volume capability Front Panel Touch Pads Alarm Silence/Reset: Push button to silence alarm or to reset; used with Battery Test button to read operating hours on Patient Pressure meter Battery Test Push button to show charge level on lower window of Patient Pressure meter Front Panel Controls Mode: Standby, Assist/Control, SIMV or Pressure Cycle Pressure Limit Locking knob sets pressure from 15 to 50 cmH2O, or disables limit feature Low Pressure Alarm 2-32 cmH2O in increments of 2 cmH2O High Pressure Alarm Limit (Assist/Control, SIMV Modes) or limit for Pressure Cycle mode 15-90 cm H2Oin increments of 5 cmH2O Volume Push-to-turn knob from 100 to 2200 mL Breath Rate 1-20 BPM in increments of 1 BPM and 22-38 BPM in increments of 2 BPM Inspiratory Time From 0.5 to 1.0 seconds in increments of 0.1 seconds; 166 Highland Park Dr. Bloomfield, CT 06002 U.S.A. Tel: (860) 218-2575 Fax: (860) 218-2565 Email: soma@somatechnology.com Rev 1 3/04 1.2 seconds; and 1.5-5.5 seconds in increments of 0.5 seconds Breathing Effort Push-to-turn knob sets pressure level to detect breathing effort: -10 cmH2O to +10 cm H2O. Front Panel Input Patient Pressure: Port for connection to proximal pressure line of patient circuit Front Panel Output Patient Air: 22 mm x 15 mm tube for connection to bacteria filter.Exhalation Valve: Port for connection to exhalation valve of patient circuit Indicators, Normal Events Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can also display battery charge and machine hours of operationBreathing Effort: Green LED activated by adequate patient breathing effortPower: LEDs indicate operating power source (green AC Pwr/Batt Chg, amber External Battery, flashing amber Internal Battery)Alarms: Flashing red LEDs (Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover) Audible Alarms Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, Setting Error, Power Switchover. Steady Tone: Loss of microprocessor control. Reminder Tone: Every 5 minutes when powered by Internal Battery and each time accessory printer generates report Rear Panel Controls AC Circuit Breaker: Internal to AC power switch (1 for ON, 0 for OFF) Rear Panel Inputs Inlet Filter: Intake for patient air; screw-off cap for filter change. External Battery: Connection for 12 VDC battery Communication Port: Calibration information during service procedure Rear Panel Outputs Vent: Cooling vent for internal ventilator components Remote Alarm: Connection for optional alarm accessories Communication Port: Connection for optional printer and digital display Maintenance Preventive maintenance by qualified professional every 6000 hours or recertification every 12 months, whichever is first Dimensions 9.75" H x 14.5" W x 13.25" D (24.6 cm x 36.8 cm x 33.6 cm) Weight Approximately 35 lb (15.9 kg) Resistance Factor Less than 0.05 cmH2O/LPM Emergency Pressure Relief Approximately 100 cmH2O Flow 20-100 LPM
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand PURITAN BENNETT
MPN LP10
Model LP10
Country/Region of Manufacture United States

Directions

Similar products from Nebulizers & Ventilators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies