Radiodetection Cat4 Plus Cable Locator Avoidance Tool

US $1,003.33

  • Phoenix, Arizona, United States
  • Jan 29th
Radiodetection CAT4 Plus Cable Locator Avoidance Tool Features: Characteristics: Radiodetection CAT4 Plus Cable Locator Avoidance Tool Avoidance Mode Searches for power, radio, and genny signals simultaneously, and when found, traces it across an area Genny Signal Locate Detects the signals transmitted by Genny4, with on-demand estimation of the depth of buried utilities Power Signal Locate Detects the electromagnetic fields generated by loaded power cables Radio Signal Locate Detects long-range radio signals as they travel along buried cables and pipes   Small Diameter Locate Frequency eCert Activated through the C.A.T Manager software, provides a fast, thorough and convenient test of the key locating circuitry within C.A.T4, and validates its performance against the original factory calibration Dynamic Overload Protection Ability to continue operating in electrically challenging areas, such as near substations and under power cables, where other locators’ detection circuitry may be overloaded and no longer function   Depth Estimation StrikeAlert (Optional) Minimises the risk of hitting a shallow cable which has been enhanced and optimised to reduce the instances of false warnings Characteristics: CAT4 Plus eCAT4 Plus /44 eCAT4 Plus /74 Avoidance Mode ♦ ♦ ♦ Genny Mode ♦ ♦ ♦ Power Signal Mode ♦ ♦ ♦ Small Diameter Locate Frequency ♦ ♦ ♦ eCert ♦ ♦ ♦ Dynamic Overload Protection ♦ ♦ ♦ Depth Estimation ♦ ♦ ♦ StrikeAlert ◊ ◊ ◊ Usage Data Logging   ♦ ♦ Service Due Indicator   ♦ ♦ SWING Warning   ♦ ♦ CALSafe   ◊ ♦ ♦ Standard ◊ Optional    Specifications: Radiodetection CAT4 Plus Cable Locator Avoidance Tool C.A.T.4 Range Locating Depth Guide (M/YDS) Locate Performance Sensitivity @ 1M Good Conditions Poor Conditions Power signals 3mA 3 2 Radio signals 25μA 2 1 Genny signals 5μA 4 2 Dynamic range 120dB @ 10 Hz Dynamic Overload protection 40 dB @ 50Hz (automatic) Locate accuracy ±10% of depth Depth accuracy Line: 5 (on undistorted signal and with no adjacent signals) Line: 5% 0.1 m to 3 m (4in to 10 ft) Sonde: 5% 0.1 m to 7 m (4 in to 16 ft) Operating temperature range -20ºC to +50ºC Environmental protection IP54 Batteries 2 x LR20 (D) 1.5 V alkaline Compatible with D type NiMH rechargeable batteries Data interface USB 2.0 Warranty (years): 1 eBay Sales – Terms and Conditions Product Condition: All listed products are brand new, and come in the original packaging with a complete manufacturer’s warranty. Warranty: All Brand New products are covered by the Manufacturer’s Standard Warranty. The Standard Warranty usually applies to a one-year period, although some products come with a longer warranty. Please consult our Customer Care for more information. Payment Terms: PayPal is the main payment method. We also accept all major credit cards (Visa, MasterCard, American Express and Discover) for orders shipped within US. International customers are encouraged to pay via bank wire transfer. If you have questions regarding payment methods, quotes or any other matter related to sales, please contact our Customer Care department. Value Testers charges 8.3% sales tax for all shipments to Arizona addresses. Shipping: We only ship to addresses verifiable by either PayPal or credit card issuing bank. Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection. Orders normally ship within 1 to 2 business days, if placed before noon MST. Tracking numbers are provided automatically. We do inspect products before a shipment is made, and all shipments are insured. In case of international shipments, clients are responsible for any duties, import taxes and brokerage fees. Shipments to Alaska and Hawaii may carry higher rates. Please contact our Customer Care department for the detailed information on shipping to Alaska and Hawaii. Returns: Before returning product, please contact our Customer Care to receive RMA (return material authorization number). Returns without RMA will not be processed. Returns of non-defective items are subject to 15% restocking fee, if returned 14 days past the delivery date. The customer is responsible for the shipping charges of the returned products. All products must be returned in their original and undamaged manufacturer’s packaging with all accessories and product manual. Return may be voided, if product is returned damaged or marked, or if any accessories or parts are missing. Please make sure to insure the return shipment, as UPS only automatically insures shipments up to $100 value. Our Customer Care can answer your questions Monday – Friday, between 7:00AM and 5:00PM MST.  
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Radiodetection
MPN 10/CAT4+EN14
Model CAT4 Plus

Directions

Similar products from Other Measurement Tools for Telecom

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies