The Raychem 3BTV2-CT self-regulating parallel circuit trace-heating cable is mostly used for frost protection of piping, which are not subjected to steam cleaning or organic corrosive environments. It may also be used in a variety of industrial applications for process temperature maintenance up to 65°C (150?F). When used in hazardous areas the unconditional T6 temperature classification simplifies designs and Raychem 3BTV2-CT can be overlapped at valves or flanges with no risk of overheating. The cut to length capability of Raychem BTV family heat tracing cables simplifies electric heat tracing designs for complex piping systems and installation times are reduced due to state-of-the-art connection kits. The self-regulating principle of Raychem BTV heating cables will ensure that the system runs efficiently, saving energy and thereby operational costs. 3BTV2-CT technical details Area classification Hazardous area, Zone 1, Zone 2 (Gas), Zone 21, Zone 22 (Dust) Traced surfaced type Carbon steel, stainless steel, plastic, painted or unpainted Chemical resistance Organic corrosive solutions Supply voltage 230 Vac     ATEX approvals PTB 09 ATEX 1115 X & Baseefa 06ATEX0183X ATEX markings Ex II 2 G Ex e II T6 & Ex II 2 D Ex tD A21 IP66 T80°C   IECEx PTB 09.0056X & IECEx BAS 06.0043X   Ex II 2 G Ex II T6 & Ex II 2 D tD A21 IP66 T80°C   DNV Certificate No E-8933 for use on ships and mobile offshore units Maintain temperature 65°C (maximum) Exposure temperature 65°C (power on)   85°C (intermittent power on – maximum cumulative exposure 1000 hours) Temperature classification T6 in accordance with European Standard EN 60079-30-1 5.1.13 Installation temperature -60°C minimum Bend radius 13mm at  20°C   35mm at -60°c 3BTV2-CT physical properties Thickness 5.5mm Width 10.5mm Weight 110 g/metre Conductors 2 x 1.2mm? nickel plated copper Outer sheath Fluoropolymer Power Output 9 watt per metre at 10°C Maximum circuit length based on type ‘C’ circuit breakers according to EN 60898 Electric protection size Start-up temperature Maximum cable length 16A -20°C 155 m    10°C 200 m 20A -20°C 195 m    10°C 200 m 25A & 32A -20°C 200 m    10°C 200 m
Off the spool
Brand Raychem
Model 3BTV2-CT

Directions

Similar products from Cable Cords & Connector Cables

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies