Rhb-10/atc Brix Refractometer W/ Atc Fruit Juice Wine Vegetable Coolants Sap

US $19.80

  • Shanghai, China
  • Mar 1st
refractometer (Digital Refractometer, Hand-held Refractometer, Hand Held Refractometer, Illumination Hand Held Refractometer, Abbe Refractometer, Bench-top Refractometer, Gem Refractometer, Gemological Refractometer) RHB-10/ATC Brix Refractometer w/ ATC Fruit Juice Wine Vegetable Coolants Sap A refractometer is an optical instrument made of high quality aluminum is used to measure the concentration or refractive index of liquids. The RHB-10ATC, is specially designed to work with sugar-related liquids such as low sugar fruits and vegetables juices, Reamsian Bodily Fluids (per the Reams Biological Theory of Ionization), Maple Sap or for synthetic or semi-synthetic coolants, soft drinks and wine (for machining and grinding coolants, please consult the Technical Data Sheet for appropriate concentration of fluid). It can help the user monitor the specific percentage of sugar concentration in food and beverages, and is especially practical for people involved with food harvesting, processing and packaging. This model is designed to give HIGHLY accurate readings with 0.10 Brix divisions (accuracy is +/- 0.10 Brix). This unit is TWICE as accurate as 0-32% models!All RHB models use ambient light which means battery or power source is not required. Models with the ATC suffix are equipped with Automatic Temperature Compensation for accurate measurements without recalibration after shifts in ambient working temperature (for field use). Against bright external light, the user looks through the eyepiece of the Brix Refractometer to see the reticle scale. The Brix Concentration (in percentage units) is the mark on the scale where the light and dark boundaries meet, with one to two drops of liquid specimen spread across the refractometer's prism glass surface. With the Brix Refractometer RHB-10ATC, you can easily check the ripeness of fruits in the field, or test the concentration of sugar in food and beverages to ensure product quality. Definitely easy to use and calibrate, this accurate optical device has a durable, lightweight body with a comfortable eyepiece and non-slip rubber grip. It also comes with its own calibrating mini-screw driver and pipette as accessories. Features: Heavy-duty, lightweight aluminum construction Easy to focus and calibrate Accurate testing results guaranteed With ATC (Automatic Temperature Compensation) built in to correct temperature discrepancies during use Operations manual, protective carrying case, pipette and calibrating mini screw driver provided for user convenience Specifications: Measuring Range 0-10% Brix Minimum Division 0.1% Brix Accuracy ±0.10% ATC Compensation Range: 10°C~30°C (50°F~86°F) Manual calibration with mini-screw driver provided Length 200 mm Weight 165g OTR series hand held refractometer is professionally designed for testing the concentration of many kinds of solution listed as following: Juices, Beverages, Honey, Oechsle, Salt water, Brine, Vital fluid, Alcohol and Grape, Cleaning fluid, Battery fluid, Antifreeze and Industrial fluids and Milk etc.. Model (click on the model No. to see picture) Measurement Range Min. Div. Accuracy Brix refractometer RSG-100/ATC 0-32%Brix SG: 1.000-1.120 0.2%Brix 0.001sg -- RHB-10/ATC 0-10%Brix 0.1%Brix ±0.10% RHB-18/ATC 0-18%Brix 0.1%Brix ±0.10% RHB-32/ATC 0-32%Brix 0.2%Brix ±0.20% RHB-50/ATC 0-50%Brix 0.5%Brix ±0.50% RHB-62/ATC 28-62%Brix 0.2%Brix ±0.20% RHB-82/ATC 45-82%Brix  0.2%Brix  ±0.5%  RHB-90/ATC 58-90%Brix 38-43Be' 12-27%water   0.5%Brix 0.5Be' 1%water ±0.50% ±0.5Be' ±1%water  RHB-92T/ATC 58-92%Brix 38-43Be' 12-27%water   0.5%Brix 0.5Be' 1%water ±0.50% ±0.5Be' ±1%water  RHB-92/ATC 58-92%Brix  0.5%Brix  ±0.5%  RHB0-80 (1scale) 0-80%Brix 1%Brix ±1%Brix RHB0-80 (2 scale) 0-50%Brix 50-80%Brix 1%Brix ±1%Brix RHB0-90 (1 scale) 0-90%Brix 1%Brix ±1%Brix RHB0-90 (3 scale) 0-42%Brix 42-71%Brix 71-90%Brix 0.2%Brix ±0.2%Brix Industrial Fluid Refractometer RHB-10/ATC 0-10%Brix 0.1%Brix ±0.10% RHB-18/ATC 0-18%Brix 0.1%Brix ±0.10% RHB-32/ATC 0-32%Brix 0.2%Brix ±0.20% Honey Refractometer RHB-90/ATC 58-90%Brix 38-43Be' 12-27%water   0.5%Brix 0.5Be' 1%water ±0.50% ±0.5Be' ±1%water  RHB-92T/ATC 58-92%Brix 38-43Be' 12-27%water   0.5%Brix 0.5Be' 1%water ±0.50% ±0.5Be' ±1%water  RHB-92/ATC 58-92%Brix  0.5%Brix  ±0.5%  RHF-30/ATC 10-30%water 1%Brix ±1% Refractometer for Oil testing RND-025/ATC 1.435-1.520Nd 0.001Nd ±0.002Nd RND-027/ATC 1.330-1..3448Nd 0.001Nd ±0.0002Nd   Salinity Refractometer RHS-10/ATC 0-10%Salinity   1.000-1.070 RI 0.1%Salinity  0.001 RI ±0.1% ±0.001 RI   RHS-28/ATC 0-28%Salinity  0.2%Salinity  ±0.2% RHS-4/ATC 2-4%Salinity(20-40ppt) SG: 1.015-1.030 0.1%(1ppt) 0.001sg Clinical refractometer RHC-200/ATC 0-12g/dl 1.000-1.050sg 1.3300RI-1.3600RI 0.2g/dl 0.005sg 0.0005RI ±0.2g/dl ±0.005sg ±0.0005RI RHC-300/ATC 2-14g/dl 1.000-1.060RI Dog 1.000-1.060RI Cat 0.2g/dl 0.001RI 0.001RI ± 0.2g/dl ± 0.001RI ± 0.001RI Oe refractometer RHB-32S/ATC 0 - 140 °Oe 0 - 27 KMW (Babo) 0 – 32%Brix (Sacch.) 1°Oe 0.2KMW 0.2%Brix ±1°Oe ±0.2KMW ±0.2%Brix RHO-150F/ATC 5-22%VOL 10-37CNM 0-30 °KMW (Babo) 0-35%Brix 0-150 °Oe 0.2%VOL 0.5 °CNM 0.5 °KMW (Babo) 0.5%Brix 1°Oe ±0.2%VOL ±0.5 °CNM ± 0.5 °KMW (Babo) ± 1°Oe RHB-32D/ATC 0 - 140 °Oe 0 – 32%Brix (Sacch.) 1°Oe 0.2%Brix ±1°Oe ±0.2%Brix RHB-44S/ATC 0 - 190 °Oe 0 - 38 KMW (Babo) 0 – 44%Brix (Sacch.) 2°Oe 0.2KMW 0.5%Brix ±2°Oe ±0.2KMW ±0.5%Brix Wine refractometer RHW-25Brix/ATC 0-25%Vol 0-40%Brix 0.2%Vol 0.2%Brix ±0.2%Vol ±0.2%Brix RHW-25Be/ATC (RHW-25Baume/ATC) 0-25%Vol 0-20 Beo 0.2%Vol 0.2%Brix ±0.2%Vol ±0.2%Brix RHW-25Oe/ATC 0-25%Vol 0-190Oe 0-44% MAS Sacch 0.5%Vol 1Oe 0.5% MAS Sacch ±0.5%Vol ±1Oe ±0.5% MAS Sacch RHW-80/ATC 0-80%w/w 1%w/w ±1%w/w Antifreeze/Battery/ Cleaning Fluids Refractometer RHA-100/ATC E:-84° F-32° F P:-60° F-32°  F B:1.100-1.400sg 5° F 5° F 0.01sg ±5° F ±5° F ±0.01sg RHA-200/ATC E:-60°C-0°C P:-50°C-0°C B:1.100-1.400sg 5°C 5°C 0.01sg ±5°C ±5°C ±0.01sg RHA-218/ATC E:-50°C-0°C (70%--0) P:-50°C-0°C (70%--0) 5°C (5%) 5°C (5%) ±5°C (5%) ±5°C (5%) RHA-300/ATC E:-60°F-32°F P:-50°F-32°F B:1.15-1.30sg 10°F 10°F 0.01sg ±10°F ±10°F ±0.01sg   RHA-402/ATC E:-50°C-0°C P:-50°C-0°C B:1.15-1.30sg 5°C 5°C 0.01sg ±5°C ±5°C ±0.01sg RHA-403/ATC E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg 5°C 5°C 5°C 0.01sg ±5°C ±5°C ±5°C ±0.01sg RHA-503/ATC B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C 0.01sg 5°C 5°C 5°C ±0.01sg ±5°C ±5°C ±5°C RHA-600/ATC E:-70°C-0°C (-90°F-32°F) P:-60°C-0°C (-70°F-32°F) B:1.100-1.400sg 5°C (10°F) 5°C (10°F) 0.01sg ±5°C (10°F) ±5°C (10°F) ±0.01sg Antifreeze/Battery/AdBlue Refractometer RHA-701/ATC Adblue: 30%--35%B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C 0.5% 0.01sg 5°C 5°C 5°C ±0.5% ±0.01sg ±5°C ±5°C ±5°C Brake fluid refractometer RBF-020F  (DOT3) DOT3 (standard fluids) Boiling point 250-500°F/1-6 H2O High Temp (Fords and Racing) Boiling point 250-570°F/1-6 H2O 1% H2O RBF-022C  (DOT4) DOT4(standard fluids) Boiling point 125-275°C/1-6 H2O PLUS(SUPER) (Fords and Racing) Boiling point 150-275°C/1-6 H2O 1% H2O Milk refractometer HB-611 0~20% milk 0.2% milk ±0.20%
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand ShowRange
Country of Manufacture China
Model RHB-10/ATC

Directions

Similar products from Measuring Devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies