Rosemount 3051ca2a22a1as1b4q Coplanar Pressure Transmitter *new* Priced To Sell

US $525.00

  • Raleigh, North Carolina, United States
  • Jun 9th
******ABSOLUTELY NEW, NEVER USED, WITH ORIGINAL PACKAGING & COVERS, NOT IN BOX****** PLEASE SEE BELOW TO IDENTIFY CONFIGURATION OF PART#'S AFTER 3051C 3051C Coplanar Pressure Transmitters Ordering Information H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Rosemount 3051C Coplanar Pressure Transmitters are the industry standard for Differential, Gage, and Absolute pressure measurement. The Coplanar Platform enables seamless integration with manifolds, flow and level solutions. Capabilities include: ? Power Advisory can proactively detect degraded electrical loop integrity issues (Option Code DA0) ? Local Operator Interface with straightforward menus and built-in configuration buttons (Option Code M4) ? Safety Certification (Option Code QT) 3051C Coplanar Pressure Transmitter Model Transmitter type 3051C(1) Coplanar Pressure Transmitter Measurement type D Differential H G Gage H A(2) Absolute Pressure range Differential (3051CD) Gage (3051CG) Absolute (3051CA) 1 –25 to 25 inH2O (-62,16 to 62,16 mbar) –25 to 25 inH2O (-62,16 to 62,16 mbar) 0to30psia (0 to 2,06 bar) H 2 –250 to 250 inH2O (-621,60 to 621,60 mbar) –250 to 250 inH2O (-621,60 to 621,60 mbar) 0 to 150 psia (0 to 10,34 bar) H 3 –1000 to 1000 inH2O (-2,48 to 2,48 bar) –393 to 1000 inH2O (-0,97 to 2,48 bar) 0 to 800 psia (0 to 55,15 bar) H 4 –300 to 300 psi (-20,68 to 20,68 bar) –14.2 to 300 psi (-0,97 to 20,68 bar) 0 to 4000 psia (0 to 275,79 bar) H 5 –2000 to 2000 psi (-137,89 to 137,89 bar) –14.2 to 2000 psi (-0,97 to 137,89 bar) N/A H 0(3) –3 to 3 inH2O (-7,46 to 7,46 mbar) N/A N/A Transmitter output A(4) 4–20 mA with Digital Signal Based on HART Protocol H F FOUNDATIONTM fieldbus Protocol H W(5) PROFIBUS® PA Protocol H X(6) Wireless (requires wireless options and engineered polymer housing) H M(7) Low-Power, 1-5 Vdc with Digital Signal Based on HART® Protocol H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Materials of construction Process flange type Flange material Drain/vent 2 Coplanar SST SST H 3(8) Coplanar Cast C-276 Alloy C-276 H 4 Coplanar Alloy 400 Alloy 400/K-500 H 5 Coplanar Plated CS SST H 7(8) Coplanar SST Alloy C-276 H 8(8) Coplanar Plated CS Alloy C-276 H 0 Alternate Process Connection H Isolating diaphragm 2(8) 316L SST H 3(8) Alloy C-276 H 4(9) Alloy 400 5(9) Tantalum (available on 3051CD and CG, Ranges 2–5 only; not available on 3051CA) 6(9) Gold-plated Alloy 400 (use in combination with O-ring Option Code B) 7(9) Gold-plated 316 SST O-ring A Glass-filled PTFE H B Graphite-filled PTFE H Sensor fill fluid 1 Silicone H 2(9) Inert (Differential and Gage only) H Housing material Conduit entry size A Aluminum 1/2–14 NPT H B Aluminum M20 x 1.5 H J SST 1/2–14 NPT H K SST M20 x 1.5 H P(10) Engineered Polymer No Conduit Entries H D(11) Aluminum G1/2 M(11) SST G1/2 Wireless options (requires Wireless Output Code X and Engineered Polymer Housing Code P) Wireless transmit rate, operating frequency, and protocol WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART H Antenna and SmartPowerTM WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately) H HART Revision configuration (requires HART Protocol Output Code A) HR5(4) Configured for HART Revision 5 H HR7(4) Configured for HART Revision 7 H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Options (include with selected model number) Extended product warranty WR3 3-year limited warranty H WR5 5-year limited warranty H PlantWeb® control functionality A01(12) FOUNDATION fieldbus Control Function Block Suite H PlantWeb diagnostic functionality DA0(13) Power Advisory HART Diagnostic H D01(12) FOUNDATION fieldbus Diagnostics Suite H Alternate flange(14) H2 Traditional Flange, 316 SST, SST drain/vent H H3(8) Traditional Flange, Alloy C, Alloy C-276 drain/vent H H4 Traditional Flange, Cast Alloy 400, Alloy 400/K-500 drain/vent H H7(8) Traditional Flange, 316 SST, Alloy C-276 drain/vent H HJ DIN-Compliant Traditional Flange,SST,7/16 in. Adapter/Manifold Bolting H FA Level Flange, SST, 2 in., ANSI Class 150, Vertical Mount 316 SST drain/vent H FB Level Flange, SST, 2 in., ANSI Class 300, Vertical Mount 316 SST drain/vent H FC Level Flange, SST, 3 in., ANSI Class 150, Vertical Mount 316 SST drain/vent H FD Level Flange, SST, 3 in., ANSI Class 300, Vertical Mount 316 SST drain/vent H FP DIN Level Flange, SST, DN 50, PN 40, Vertical Mount 316 SST drain/vent H FQ DIN Level Flange, SST, DN 80, PN 40, Vertical Mount 316 SST drain/vent H HK(15) DIN Compliant Traditional Flange, SST, 10 mm Adapter/Manifold Bolting 316 SST HL DIN Compliant Traditional Flange, SST, 12mm Adapter/Manifold Bolting 316 SST Manifold assembly(16) S5 Assemble to Rosemount 305 Integral Manifold H S6 Assemble to Rosemount 304 Manifold or Connection System H Integral mount primary element(15)(16) S3 Assemble to Rosemount 405 Compact Orifice Plate H S4(17) Assemble to Rosemount Annubar® or Rosemount 1195 Integral Orifice H Seal assemblies(16) S1(18) Assemble to one Rosemount 1199 seal H S2(19) Assemble to two Rosemount 1199 seals H Mounting bracket(20) B4 Coplanar flange bracket, all SST, 2-in. pipe and panel H B1 Traditional flange bracket, CS, 2-in. pipe H B2 Traditional flange bracket, CS, panel H B3 Traditional flange flat bracket, CS, 2-in. pipe H B7 Traditional flange bracket, B1 with SST bolts H B8 Traditional flange bracket, B2 with SST bolts H B9 Traditional flange bracket, B3 with SST bolts H BA Traditional flange bracket, B1, all SST H BC H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery. __The Expanded offering is subject to additional delivery lead time. Product certifications E8 ATEX Flameproof and Dust Certification H I1(21) ATEX Intrinsic Safety and Dust H IA ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus or PROFIBUS PA protocol only H N1 ATEX Type n Certification and Dust H K8 ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1) H E4(22) TIIS Flame-proof H E5 FM Explosion-proof, Dust Ignition-Proof H I5(23) FM Intrinsically Safe, Nonincendive H IE FM FISCO Intrinsically Safe; for FOUNDATION fieldbus or PROFIBUS PA protocol only H K5 FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2 H C6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 H I6(10) CSA Intrinsic Safety H K6 CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1) H E7 IECEx Flameproof, Dust Ignition-proof H I7 IECEx Intrinsic Safety H N7 IECEx Type n Certification H K7 IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7) H E2 INMETRO Flameproof H I2 INMETRO Intrinsic Safety H IB INMETRO FISCO intrinsically safe; for FOUNDATION fieldbus or PROFIBUS PA protocols only H K2 INMETRO Flameproof, Intrinsic Safety H E3 China Flameproof H I3 China Intrinsic Safety H N3 China Type n H EM Technical Regulations Customs Union (EAC) Flameproof H IM Technical Regulations Customs Union (EAC) Intrinsic Safety H KM Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety H KB FM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6) H KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8) H Drinking water approval DW(24) NSF drinking water approval H Shipboard approvals SBS(9) American Bureau of Shipping H SBV(9)(25) Bureau Veritas (BV) H SDN(9) Det Norske Veritas H SLL(9)(25) Lloyds Register (LR) H Custody transfer C5(13) Measurement Canada Accuracy Approval (limited availability depending on transmitter type and range; contact an Emerson Process Management representative)                        Bolting material L4 Austenitic 316 SST Bolts H L5 ASTM A 193, Grade B7M Bolts H L6 Alloy K-500 Bolts H Display and interface options M4(26) LCD Display with Local Operator Interface H M5 LCD Display H Calibration certificate Q4 Calibration Certificate H QG(27) Calibration Certificate and GOST Verification Certificate H QP Calibration certification and tamper evident seal H Material traceability certification Q8 Material Traceability Certification per EN 10204 3.1 H Quality certification for safety QS(13) Prior-use certificate of FMEDA data H QT(13) Safety certified to IEC 61508 with certificate of FMEDA H Configuration buttons D4(13) Analog Zero and Span H DZ(28) Digital Zero Trim H Transient protection T1(9)(29) Transient Protection Terminal Block H Software configuration C1(28) Custom Software Configuration (completed CDS 00806-0100-4007 for wired and 00806-0100-4100 for Wireless required with order) H Low power output C2 0.8-3.2 Vdc Output with Digital Signal Based on HART Protocol (available with Output code M only) H Gage pressure calibration C3 Gage Calibration (Model 3051CA4 only) H Alarm levels C4(13) Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High H CN(13) Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm Low H CR(13) Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet) H CS(13) Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet) H CT(13) Rosemount standard low alarm H Pressure testing P1 Hydrostatic Testing with Certificate Cleaning process area P2 Cleaning for Special Service P3 Cleaning for <1 PPM Chlorine/Fluorine Flange adapters DF(30) 1/2 -14 NPT flange adapter(s) H Vent/drain valves D7 Coplanar Flange Without Drain/Vent Ports Conduit plug DO(9)(31) 316 SST Conduit Plug H RC1/4 RC1/2 process connection D9(32) RC 1/4 Flange with RC 1/2 Flange Adapter - SST Max static line pressure P9 4500 psig (310,26 bar) Static Pressure Limit (3051CD Ranges 2–5 only) H Ground screw V5(9)(33) External Ground Screw Assembly H Surface finish Q16 Surface finish certification for sanitary remote seals H Toolkit total system performance reports QZ Remote Seal System Performance Calculation Report H Conduit electrical connector GE(9) M12, 4-pin, Male Connector (eurofast®) H GM(9) A size Mini, 4-pin, Male Connector (minifast®) H NACE certificate Q15(34) Certificate of Compliance to NACE MR0175/ISO 15156 for wetted materials H Q25(34) Certificate of Compliance to NACE MR0103 for wetted materials H Typical model number: 3051CD 2 A 2 2 A 1 A B4 (1)  Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required. (2)  If ordered with Wireless output code X, only Range 1-4, 316L SST diaphragm material (code 2), silicone fill fluid (code 1) and wireless housing (code P) are available. (3)  3051CD0 is only available with output code A and X. For output code A, only process flange code 0 (Alternate flange H2, H7, HJ or HK), isolating diaphragm code 2, O ring code A and bolting option L4 are available. For output code X, only process flange code 0 (Alternate flange H2), isolating diaphragm code 2, O ring code A and bolting option L4 are available. (4)  Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output. (5)  For local addressing and configuration, M4 (Local Operator Interface) is required. (6)  Available approvals are FM Intrinsically Safe, (Option Code I5), CSA Intrinsically Safe (Option Code I6), ATEX Intrinsic Safety (Option Code I1), IECEx Intrinsic Safety (Option Code I7) and EAC Intrinsic Safety (option code IM). (7)  Only available with C6, E2, E5, I5, K5, KB and E8 product certifications. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, CT.   Traditional flange bracket, B3, all SST H
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand Emerson
MPN 3051C A2A22A1AS1B4Q4
Model 3051C

Directions

Similar products from Pressure & Temperature Transmitters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies