Siemens Cerberus Pyrotronics Model Fpi-32 Programmer/tester For The Xl3/mxl Sys

US $260

  • Jersey City, New Jersey, United States
  • Jun 2nd
Lightly used. Looks new Used it for 1 big project.  Here's the specs: • Built-in DB-3S Base for Use with Detectors • Jack for Use with Manual Stations, Interface Modules and ICP Modules • Green Light on Keyboard Indicates Charger On • Red Light on Keyboard Indicates Low Battery • Automatic Shut Off After 5 Minutes of Keyboard Inactivity • Optional Carrying Case • Listed, ULC Listed, FM and CSFM Approved Program Mode: • Electronically sets address into device’s chip memory • Automatically verifies programmed address • Automatically verifies device’s functionality • Stores in memory last programmed address until power is off • Eliminates need for mechanical address programming pins, dipswitches or rotary dials Test Mode: • Automatically performs a sequence of functionality tests • Informs user if device has passed or failed tests Operation The keyboard includes three mode keys, one for pro- gramming, one for testing and one for special menu functions, as well as keys for yes, no, clear, numbers 0 to 9, on and off and a 2 line by 16 character LCD display. The keys to turn the FPI-32 on and off are colored blue and are on the opposite end of the keyboard from the other keys. All questions or menu selections can be made using either the yes, no, clear, or numeric keys 0 through 9. The yes, no and clear keys are red colored and appear on the keyboard as YES, NO and C respectively. When the C key is pressed the FPI-32 will either clear any current user entry or return the user to the previously shown text. The numeric keys are blue colored and are used to assign a device’s numeric address. For the XL3 system, the FPI-32 will accept address numbers 1 through 30. For the MXL and IXL systems, the FPI-32 will accept address numbers 1 through 60. If the user attempts to use an unacceptable numeric address, the FPI-32 will give the user an “invalid address” error message. Three main mode keys found on the keypad allow the user to select between a program, test or special menu mode. These keys are colored red and are labeled as “PROG,”“TEST”and“MENU”respectively. Upon selection of a mode, the FPI-32 guides the user in completing a program or test by the use of questions. If the user desires to use or switch to a different mode anytime the FPI-32 is being operated, the user may do so by simply pressing the desired “PROG,” “TEST” or “MENU” key. If the user wishes to program an Intelligent Initiating Device’s address, the PROG key is pressed. The FPI-32 will ask if the user is using an XL3 or MXL control panel. When programming or testing “I” Series devices for the IXL system, the “MXL” choice is selected. Then the FPI- 32’s menu question format will guide the user, so the user can program the device’s new address. The FPI-32 will also automatically test the device for functionality and will verify the device’s new address. This process takes less time and is more accurate than any other programming method available in today’s market. The device’s address is electronically set by the FPI-32. The FPI-32 will hold in its memory the last programmed address number. When the user is ready to program another intelligent device’s address, the FPI-32 will automatically query the user if the next address in sequence should be used. The user may either select the next sequenced address or input a different address. The FPI-32 address sequence memory will remain active until the FPI-32 is turned off. The FPI-32 also has two device testing modes. The first test mode can be used by pressing the TEST key. The TEST mode will automatically perform a sequence of functionality tests and inform the user if the device has passed or failed the functionality test. The second test mode can be used by pressing the MENU key. The user has several test and test-function options in the MENU mode. The MENU mode is designed for the advanced technician who is familiar with the device’s analog responses.The device’s analog responses which are displayed by the FPI-32 are the CAL, ID1, ID2 and ANA- LOG2 values. During any mode, when the FPI-32 tests a detector, the FPI-32 will pulse only a functional detector’s LED. Also, when testing a TRI-60R interface or ICP, the FPI-32 will switch the interface’s relay on and off. For portability, the FPI-32 is designed to operate on its own battery power for up to four hours when the batter- ies are fully charged. The user can carry the FPI-32 to an area where it is most convenient to address or test the device.The FPI-32 has six standard long-life rechargeable batteries. To keep the batteries from being depleted when the FPI-32 is not in use, the FPI-32 is designed to automatically shut off if the keypad is not used for 5 minutes. For longest battery life, the batteries should be fully recharged when the red, “low battery” light comes on. The AC adapter supplies AC power for the FPI-32 and for recharging its batteries. When the AC adapter is used a green light on the keyboard will come on to indicate the batteries are being charged. A jack is for use with intelligent manual stations, inter- faces modules, ICP control modules and CZM-1 Conven- tional Zone Module. The FPI-32 has built in polarization equalizer which automatically ensures the proper polarity connection to a manual station or interface module or CZM-1 module. There is an indented area on the FPI-32 for resting a manual station, an interface device or a CZM-1 module. The FPI-32 is designed to take shocks from a typical field handling. For instance, a drop from table height will typically not affect the FPI-32.

Directions

Similar products from Other Fire Protection Systems & Tools

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies