Site Master Sa2500ex -(lot Of 2sets) Bird With Calkit Cal-mnc,sensor Dps-5010

US $5,495.00

  • Faridabad, Haryana, India
  • Jan 29th
This sale is in lots. Each lot consists of 2 Site masters with accessories. Each lot consits of : 1)SA2500EX -2 nos 2) Power Supply adaptor - 2nos 3) Power sensor -DPS5010 -2 noshttp://www.bird-technologies.com/en/Products/Power-Measurement/DPS-Series-Directional-Power-Sensors/5010B-Directional-Power-Sensor-DB9.aspx#.Ua8ae9JHJAs 4) Cal-kit CALMNC- 2nos http://www.bird-technologies.com/en/Products/Terminations_Loads/Calibration-Standard-Terminations/CAL-MN-C_Calibration-Standard-Termination-M-N.aspx 5)Two elements (As per availability)-2 noshttp://www.bird-technologies.com/Products/Plug-In-Elements/7-8-inch-Plug-In-Elements/DPM-Elements.aspx#.Ua8a_9JHJAs 6) Serial Cable-2 nos 7) Serial to USB Cable for data transfer- 2nos 8)Two adaptors and two jumpers-2 nos 9) CD-2 nos For complete technical details , pls refer http://www.bird-technologies.com/ Bird SA-2500EX Site Analyzer 780 MHz to 2500 MHz Features: • Easy to operate and field ready for first-time, occasional and experienced users • Suitable for use in Worldwide Cellular and PCS/DCS systems; supporting measurement of CDMA, GSM, TDMA and AMPS modulation schemes • Other applications include 3G, Broadcast, Government, Tactical Military, Microwave, Paging, Public Safety, Trunking, WLAN and WLL, and TETRA. See model matrix below • Color display is clearly visible in direct sunlight • With a single download you can view data as Distance to Fault or Measurement Match-no need to store two traces. • FDR (Frequency Domain Reflectometry) measurement method results in a highly reliable assessment of the health of critical components in your system; ultimately providing a “heads-up” before a failure occurs • Fault location or DTF mode indicates VSWR or Return Loss levels at each point along the cable and antenna system length • Cable Loss function measures insertion loss of the cable system over a given frequency ran Model #  SA-2500EX Frequency Range 780-2500 MHz  Frequency Resolution 50kHz  Power Measurement  Yes Return Loss 0 to -60 dB  Test Port N-type female connector Impedance 50  Speed 1 multi-frequency scan (238 points)/2 seconds 1 multi-frequency scan (475 points)/3.5 seconds 1 multi-frequency scan (949 points)/6 seconds  Trace Resolution 238 (default), 475, or 949 per trace Storage Capacity 15 Set-Ups/(500) 238 point traces  Immunity to Interfering Signals Rejects on-frequency signals up to +13 dBm Maximum Input Signal +22 dBm  Data Transfer 9-pin RS-232 (DB9), compatible with serial port Internal time Rechargeable Lithium-Ion batteries. 3-hour minimum operating time. Auto shut-off conserves battery life. External DC 9-16 VDC fused, < 3 A External AC 90 to 264 VAC @ 45-66 Hz; AC/DC adapter required Operating Temperature -10° to +50° C (+14° to +122° F) Storage Temperature -40° to +80° C (-40° to +176° F) Humidity 95% ± 5% max., (non-condensing) Altitude Up to 15,000 feet (4572 m) Dimensions 10.5 ” x 8.4” x 3.3” (265 x 212 x 83 mm) Weight 5.5 lbs. (2.5 kg)  Upgradeable  Delivery by DHL. All our sales are final and nonreturnable
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Site masters are fairly used . In perfect working condition with calibration of perfect 1 with calkit .

Directions

Similar products from Cable Fault Locators, Stress Test Sets & Power Sensors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies