Spectralert P121575 Horn Strobe By System Sensor

US $28.00

  • Madison, Wisconsin, United States
  • Jan 30th
SYSTEM SENSOR-SPECTRALERT- HORN/STROBE-P121575 TWO AVAILABLE-SELLING ONE AT A TIME-BUY BOTH SHIPPING COMBINED THANKS SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 11/ 2 back box or a single gang 17/ 8 back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert products, when used in conjuction with the accessory Sync·Circuit Module, shall be powered from a non-coded power supply and shall operate or 24 volts. 12 volt rated devices shall have an operating voltage range of 10.7­17 volts. 24-volt rated devices shall have an operating voltage range or 20­30 volts. SpectrAlert products shall have an operating temperature to 120°F and operate from a regulated DC or full wave rectified, unfiltered power supply. Horn shall be a System Sensor SpectrAlert Model capable of operating at 12 and 24 volts. Horn shall be listed UL 464 for fire protective signaling systems. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. All horn models shall operate on a coded power supply. Horn/Strobe shall be a System Sensor SpectrAlert Model listed UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/strobe models shall operate on a coded or non-coded power supply (the strobe must be powered continuously). Strobe shall be a System Sensor SpectrAlert Model listed UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Module shall be a System Sensor Sync·Circuit listed UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting 411/16x 21/8 back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand SpectrAlert
MPN N04-1423-046
Model P121575

Directions

Similar products from Warning Lights & Emergency Beacons

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies