SUN ELECTRONIC SYSTEMS EC12  ENVIRONMENTAL TEST CHAMBER LABORATORY GENERAL SPECIFICATIONS  MECHANICAL Internal Dimensions ......................................(50.8cmW x 30.5cmH x 40.6cmD).......20.0"W x 12.0"H x 16.0"D Test Volume ................................................................................(0.062 m?)........................................2.2 ft? Overall Dimensions ....................................(76.2cmW x 49.5cmH x 76.2cmD)........30.0"W x 19.5"H x 30.0"D Exterior Construction ...................................................................................................Painted Aluminum Alloy Door (see options) ..........................................................................................Blank door supplied with chamber Interior Construction ....................................................................................Stainless Steel, with exhaust port Coolant Input .................................................................................................LCO2, 37?  male fitting, 1/4" tube  (optional) LN2 , 45?  male fitting, 1/2" tube Exhaust ......................................................................................................................................1/2" NPT, male Weight ........................................................(36 kg typical; 45kg shipping).......80lbs typical; 100 lbs shipping PERFORMANCE Set Temperature Range (LCO2 ) ..............................................(-100?F to +600?F).................. -73? C to +315? C With LN2  Option ................................................................(-300?F to +600?F)...................-184? C to +315? C Temperature Ramping Rate Range (Heating and Cooling)........(0.02?F to 27?F/min).......... 0.01?C to 15?C/min Number of Programmable Temperature Setpoints ..................................................................Typically 100+ Time at Temperature Setpoint Range................................................................1.0 sec to 99 hr, 59 min, 59 sec Number of Programmable Set Times ........................................................................................Typically 100+ Air Circulation ...........................................................................................................................150 CFM, vertical Absolute Error Over Temp Range (not including probe error).. ...................................(±0.9?F)...........±0.5? C Temperature Resolution (approx.)........................................................................(0.04°F).................0.02?C Long Term Stability (per month)...............................................................................(±0.4?F)..............±0.2? C Line Voltage Sensitivity ................................................(±0.2?F)...................±0.1? C for 105 VAC to 125 VAC Temperature Control Technique .............................................................................Dual PID Algorithm, PWM Ambient Temperature Operating Range ..........................................(32?F to 122?F)........................0? C to 50? C Local Control...........................................................................................29 Key Keyboard (2 Line LCD Display) Remote Control..............................................................................................RS232 / RS422 / IEEE-488 bus IEEE-488 to RS232/RS422 ....................................................... Software/Bidirectional Transparent Operation SAFETY Line Voltage Dropout ........................................... Program and Parameters Stored in Battery Backed Memory ( Programmable Automatic Restart after Power Loss ) Fail Safe ..................................................................................Open/Short Probe Detection, Watch-dog Timer, Software Temperature Limits, Over-temperature Thermostat ELECTRICAL Heating Input ............................................................................................................................1800 Watts Power Requirements .................................................................2200 Watts max,120 VAC, 50/60 Hz, 1 phase Optional 208 VAC, 110 VAC (50 Hz) and 240 VAC  (176664) In Stock Ships within 24 Hours of Cleared Payment  Units comes with a 30 day warranty and if it fails within a 30 day period it may be returned for a full refund.  Seller will pay return shipping on any units that need to be returned.  Returns not accepted if unit has been damaged.  Units must be returned in original shipping package. NOTICE: This unit ships on a pallet, Weight is 100 lbs  Dimensions are 34" x 34" x 40" (AECI can and will, upon buyers request, ship an item via FedEx, UPS, or DHL or any other preferred carrier on buyers account number if provided.  If International, please inquire prior to purchasing if you wish to exercise this option and we can offer a listing that does not go through eBay’s Global Shipping Program.)   American Electronic Components, Inc. (AECI) Serving the Electronic and Telecom Industry since 1979
Unit pulled from working environment, comes with 30 day warranty.
Brand Sun Electronic Systems
Country/Region of Manufacture United States
Model EC12

Directions

Similar products from Environmental & Testing Chambers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies