Tekmar 132

US $225.00

  • Cleveland, Ohio, United States
  • Mar 12th
 Control Description: The Pump Sequencer 132 is designed to provide pump control for either stand-by or 2-stage operation. In stand-by mode, the 132 automatically switches over from the lead pump to the stand-by pump during a pump failure. In 2-stage mode, the 132 turns on the second stage pump to meet additional flow requirements. Literature + D 132, A 132Ts, D 001 Control + Microprocessor PID control; This is not a safety (limit) control Packaged Weight + 2.9 lb. (1320 g), Enclosure A, blue PVC plastic Dimensions + 6-5/8" H x 7-9/16" W x 2-13/16" D (170 x 193 x 72 mm) Approvals + CSA C US, meets ICES & FCC regulations for EMI/RFI Ambient Conditions + Indoor use only, 32 to 120+F (0 to 50+C), < 90% RH non-condensing Power Supply + 120 V +10% 50/60 Hz 6 VA Pump Relays + 240 V (ac) 10 A 1/2 hp, pilot duty 3 A 720 VA Alarm Relays + 240 V (ac) 10 A 1/3 hp, pilot duty 2 A 240 VA Demands + 20 to 260 V (ac) 2 VA Sensors + NTC thermistor, 10 k? @ 77+F (25+C +0.2+C) +=3892 Optional + Outdoor Sensor 070 Type: Control Width (Inches): 7-9/16" Height: 6-5/8" Stages: ? Stages close Stages describes the number of heat or cool sources that you need to control with a single thermostat. 2 Boiler User Interface: DIP Switch Application: Multiple Boilers Voltage: ? Voltage close Voltage, or volts, is a measurement of the difference between two electric fields (in heating terms, the difference between the Earth's electrical field and the electricity running through your wires). 260v Depth (Inches): 2-13/16" Ambient Conditions: Indoor Only: 32°-120°F <90% RH Non-Condensing Power Supply: 120V (ac) Relays: 240 V (ac) 10 A-1/2 hp- pilot duty 3 A 720 VA Sensors: NTC Thermistor 10 k ohm @ 77°F Weight (lbs): 2.9 lbs Pump Relays: 10 A @ 240 V (ac) 3 A @ 720 VA (Pilot Duty) 1/2 hp Alarm Relays: 10 A @ 240 V (ac) 1/3 hp 2 A @ 240 VA (Pilot Duty) Enclosure Type: A
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand tekmar
Model 132

Directions

Similar products from Other Heating, Ventilating & Air Conditioning Items

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies